6533b82efe1ef96bd1292a4c

RESEARCH PRODUCT

CT-guided stereotactic biopsy aided by Doppler ultrasonic vascular monitoring

Axel PerneczkyJürgen BohlK. UngersböckP. GrunertWibke Müller-forell

subject

AdultMalemedicine.medical_specialtyStereotactic biopsyAdolescentStereotaxic Techniquessymbols.namesakeBiopsymedicineHumansSampling (medicine)ChildAgedNeuroradiologymedicine.diagnostic_testBrain Neoplasmsbusiness.industryBiopsy NeedleInterventional radiologyCerebral ArteriesMiddle AgedEchoencephalographyCannulaChild PreschoolsymbolsFemaleSurgeryUltrasonic sensorNeurology (clinical)RadiologyTomography X-Ray ComputedbusinessDoppler effectBlood Flow Velocity

description

The use of a 20 MHz pulsed Doppler technique during stereotactic brain tumour biopsies is described. By means of a miniaturized ultrasonic probe the tissue planned for biopsy was investigated for vessel signals. Out of 41 patients, with this technique a flow-pulse curve in front of the biopsy cannula was registered in 14 cases. In 9 cases one pulse curve was determined and in 5 cases two or more flow curves were found, indicating the presence of arterial vessels. The depth of the vessels signal could be localized and this area avoided for biopsy sampling. In a series of 41 stereotactic biopsies carried out in this way there was no intra-operative haemorrhage or postoperative haematoma.

https://doi.org/10.1007/bf01406375