Pressure Monitoring of Intraneural an Perineural Injections Into the Median, Radial, and Ulnar Nerves; Lessons From a Cadaveric Study
Matthew SzarkoAndrzej KrólArber ValaJose De Andressubject
Peripheral nerve blockademedicine.medical_specialtybusiness.industryPeripheralSurgeryInjectionsRadial NervesDissectionAnesthesiology and Pain MedicineRegional anesthesiaPressureMedicinePressure monitoringPounds per square inchbusinessUlnar nerveCadaveric spasmNuclear medicineResearch Articledescription
Background: Nerve damage after regional anesthesia has been of great concern to anesthetists. Various modalities have been suggested to recognize and prevent its incidence. An understudied area is the measurement of intraneural pressure during peripheral nerve blockade. Previous investigations have produced contradicting results with only one study being conducted on human cadavers. Objectives: The purpose of this investigation was to systematically record intraneural and perineural injection pressures on the median, ulnar, and radial nerves exclusively as a primary outcome. Materials and Methods: Ultrasonography-guided injections of 1 mL of 0.9% NaCl over ten seconds were performed on phenol glycerine embalmed cadaveric median, ulnar, and radial nerves. A total of 60 injections were performed, 30 intraneural and 30 perineural injections. The injections pressure was measured using a controlled disc stimulation device. Anatomic dissection was used to confirm needle placement. Results: Intraneural needle placement produced significantly greater pressures than perineural injections did. The mean generated pressures in median, radial, and ulnar nerves were respectively 29.4 ± 9.3, 27.3 ± 8.5, and 17.9 ± 7.0 pound per square inch (psi) (1 psi = 51.7 mmHg) for the intraneural injections and respectively 7.2 ± 2.5, 8.3 ± 2.5, and 6.7 ± 1.8 psi for perineural injections. Additionally the intraneural injection pressures of the ulnar nerve were lower than those of the median and radial nerves. Conclusions: Obtained results demonstrate significant differences between intraneural and perineural injection pressures in the median, ulnar, and radial nerves. Intraneural injection pressures show low specificity but high sensitivity suggesting that pressure monitoring might be a valuable tool in improving the safety and efficacy of peripheral nerve blockade in regional anesthesia. Peripheral nerves “pressure mapping” hypothetically might show difference amongst various nerves depending on anatomic location, histologic structure, and ultrasonographic appearance.
year | journal | country | edition | language |
---|---|---|---|---|
2015-06-22 | Anesthesiology and Pain Medicine |