Emmanouela RepapiConstantinos C. RepapisPanagiotis G. AsterisLiborio Cavalerisubject
EngineeringInfill wallModal analysis0211 other engineering and technologies020101 civil engineeringOcean Engineering02 engineering and technologyreinforced concrete frame buildingSpan (engineering)0201 civil engineeringSeismic analysisregression analysiFundamental periodmedicineInfillGeotechnical engineeringSafety Risk Reliability and QualityCivil and Structural Engineering021110 strategic defence & security studiesmodal analysibusiness.industryinfilled frameMechanical EngineeringStiffnessStructural engineeringBuilding and ConstructionMasonryGeotechnical Engineering and Engineering GeologyVibrationSettore ICAR/09 - Tecnica Delle Costruzionimasonrymedicine.symptombusinessdescription
AbstractThe fundamental period of vibration appears to be one of the most critical parameters for the seismic design and assessment of structures. In the present paper, the results of a large-scale analytical investigation on the parameters that affect the fundamental period of reinforced concrete structures are presented. The influence of the number of storeys, the number of spans, the span length, the infill wall panel stiffness and the percentage of openings within the infill panel on the fundamental period of infilled RC frames was investigated. Based on these results, a regression analysis is applied in order to propose a new empirical equation for the estimation of the fundamental period. The derived equation is shown to have better predictive power compared with equations available in the literature.
year | journal | country | edition | language |
---|---|---|---|---|
2016-09-15 |