Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Performance of Single Lead VDD Pacemakers

Torsten PeifferUdo ReispJürgen PotratzBernd NowakUwe K.h. WiegandFrank Bode

subject

AdultMalemedicine.medical_specialtyTime FactorsAtrial sensingSensitivity and SpecificityPacemaker systemElectrocardiographyIntraoperative fluoroscopyInternal medicineHumansMulticenter Studies as TopicMedicineHeart Atriacardiovascular diseasesAgedRetrospective StudiesAged 80 and overbusiness.industryP waveCardiac Pacing ArtificialEquipment DesignGeneral MedicineMiddle AgedDipoleHeart Blockmedicine.anatomical_structureSingle leadAtrioventricular Nodecardiovascular systemCardiologyRight atriumEquipment FailureFemaleCardiology and Cardiovascular MedicinebusinessHolter monitoringFollow-Up Studies

description

WIEGAND, U.K.H., et al.: Implantation Strategy of the Atrial Dipole Impacts Atrial Sensing Perfor-mance of Single Lead VDD Pacemakers. Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep and shallow respiration. Atrial dipole position was determined by intraoperative fluoroscopy subdividing the right atrium in a high, mid, and low portion. Undersensing was defined by evidence of at least one not sensed P wave during Holter monitoring or exercise testing and by the presence of 0.1–0.2 mV amplitudes in the P wave amplitude histogram of the pacemaker. Incidence of undersensing was 25.8%; 9.3% of patients showed frequent (> 5%) or symptomatic undersensing. Patients with undersensing were older (76.6 ± 10.6 vs 64.2 ± 14.8 years), showed a lower minimum of intraoperative atrial potential amplitude (Pmin 0.86 ± 0.64 vs 1.43 ± 0.77 mV), a wider range of potential amplitude (ΔP 1.71 ± 1.44 vs 0.94 ± 0.84 mV), and a higher incidence of dipole placement in the low right atrium (50.0% vs 11.1%, P 66 years, Pmin 1.3 mV and atrial dipol placement in the low right atrium were independently predictive for undersensing. Minimal atrial potential amplitude, range of potential amplitude, and atrial dipole position influence atrial sensing performance in single lead VDD pacing. Thus, implantation guidelines should reflect these rules to improve the outcome of VDD pacemaker recipients.

https://doi.org/10.1046/j.1460-9592.2002.00316.x