6533b85afe1ef96bd12b8d7b

RESEARCH PRODUCT

Multislice multiecho T2* cardiovascular magnetic resonance for detection of the heterogeneous distribution of myocardial iron overload.

Alessia PepeMassimo MidiriVincenzo PositanoEliana CracoliciAurelio MaggioMassimo LombardiLuigi LandiniDaniele De MarchiMaria Filomena SantarelliFortunato Sorrentino

subject

AdultMaleLiver Iron ConcentrationthalassemiaAdolescentHeart VentriclesIronCoefficient of variationCardiomyopathyMagnetic Resonance Imaging CineImage Processing Computer-AssistedHumansMedicineDistribution (pharmacology)magnetic resonance imagingRadiology Nuclear Medicine and imagingMultisliceiron overloadChildObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryMyocardiumbeta-ThalassemiaReproducibility of Resultsrelaxation time (T2*)Magnetic resonance imagingMiddle Agedmedicine.diseasemedicine.anatomical_structureLiverVentricleFerritinsFemalebusinessNuclear medicinecardiomyopathy

description

Purpose To assess the tissue iron concentration of the left ventricle (LV) using a multislice, multiecho T2* MR technique and a segmental analysis. Materials and Methods T2* multiecho MRI was performed in 53 thalassemia major patients. Three short-axis views of the LV were obtained and analyzed with custom-written software. The myocardium was automatically segmented into 12 segments. The T2* value on each segment as well as the global T2* value were calculated. Cine dynamic images were also obtained to evaluate biventricular function parameters by quantitative analysis. Results For the T2* global value, the coefficient of variation (CoV) for intra-/interobserver and interstudy reproducibility was 3.9% (r = 0.98), 5.5% (r = 0.98), and 4.7% (r = 0.99) respectively. Three groups were identified based on analysis of myocardial T2*: homogeneous (21%), heterogeneous (38%), and no myocardial iron overload (41%). The mean serum ferritin, liver iron concentration, and urinary iron excretion were significantly different among the groups. We did not find significant differences among groups in biventricular function. There was a correlation between the global T2* value and the T2* value in the mid-ventricular septum (r = 0.95, P < 0.0001). Conclusion Multislice multiecho T2* MRI provides a noninvasive, fast, reproducible means of assessing myocardial iron distribution. The single measurement of mid-septal T2* correlated well with the global T2* value. J. Magn. Reson. Imaging 2006. © 2006 Wiley-Liss, Inc.

10.1002/jmri.20566http://hdl.handle.net/10447/10242