6533b85ffe1ef96bd12c1bf1
RESEARCH PRODUCT
Reliability of a new analysis to compute time to stabilization following a single leg drop jump landing in children.
Daniel JandackaXavier García MassóIsaac EstevanJiri Skypalasubject
MaleResearch ValidityMuscle PhysiologyTime FactorsPhysiologyIntraclass correlationPolynomialsSignalRoot mean square0302 clinical medicineContinuous waveletStatisticsMedicine and Health SciencesBiomechanicsChildMusculoskeletal SystemReliability (statistics)MathematicsSignal processingMultidisciplinaryQRResearch AssessmentBiomechanical PhenomenaSignal FilteringPhysiological ParametersPhysical SciencesEngineering and TechnologyLegsMedicineFemaleAnatomyResearch ArticleMovementScienceResearch and Analysis Methods03 medical and health sciencesHumansMechanical PhenomenaLegBody WeightBiology and Life SciencesReproducibility of Results030229 sport sciencesAlgebraTransformation (function)Standard errorBody LimbsSignal ProcessingMusculoskeletal MechanicsMathematics030217 neurology & neurosurgerydescription
Although a number of different methods have been proposed to assess the time to stabilization (TTS), none is reliable in every axis and no tests of this type have been carried out on children. The purpose of this study was thus to develop a new computational method to obtain TTS using a time-scale (frequency) approach [i.e. continuous wavelet transformation (WAV)] in children. Thirty normally-developed children (mean age 10.16 years, SD = 1.52) participated in the study. Every participant performed 30 single-leg drop jump landings with the dominant lower limb (barefoot) on a force plate from three different heights (15cm, 20cm and 25cm). Five signals were used to compute the TTS: i) Raw, ii) Root mean squared, iii) Sequential average processing, iv) the fitting curve of the signal using an unbounded third order polynomial fit, and v) WAV. The reliability of the TTS was determined by computing both the Intraclass Correlation Coefficient (ICC) and the Standard Error of the Measurement (SEM).In the antero-posterior and vertical axes, the values obtained with the WAV signal from all heights were similar to those obtained by raw, root mean squared and sequential average processing. The values obtained for the medio-lateral axis were relatively small. This WAV provided substantial-to-good ICC values and low SEM for almost all the axes and heights. The results of the current study thus suggest the WAV method could be used to compute overall TTS when studying children's dynamic postural stability.
year | journal | country | edition | language |
---|---|---|---|---|
2019-02-12 | PLoS ONE |