6533b870fe1ef96bd12d0522

RESEARCH PRODUCT

Decontamination of a barrier facility using microisolator cages and provisional partitioning

Elena WieseSimone MaurerGisela SteigeSigrid Saaler-reinhardtKurt ReifenbergSibylle OttBernd Dr. Lecher

subject

Veterinary medicineGeneral VeterinaryHygieneBiologybiology.organism_classificationHousing AnimalVirologyDisease OutbreaksSpecific Pathogen-Free OrganismsMiceMyobia musculiSyphacia obvelataFacility Design and ConstructionAnimalsAnimal Science and ZoologyAnimal HusbandryDecontamination

description

In 2000, the authors found endemic infections of mouse hepatitis virus, minute virus of mice, Syphacia obvelata, and Myobia musculi among mice in a large barrier facility at the University of Mainz. To eliminate the infections, they subdivided the facility into two distinct hygiene units. However, architectural constraints made it impossible to completely separate the HVAC systems of both hygiene units and to establish adequate personnel locks. To compensate for these suboptimal barrier conditions of the two newly established units, the authors replaced the open-top caging and open-servicing system with filter-top cages that were manipulated in cage-changing stations. The authors then depopulated the two units in series, independently eliminating the contaminated mice and restocking the units with SPF animals. In spite of the high infection pressure and the suboptimal barrier conditions, the authors had only a single case of recontamination.

https://doi.org/10.1038/laban0707-31