6533b871fe1ef96bd12d1965
RESEARCH PRODUCT
Sensitivity and specificity of a commercial ELISA test for anti-MAG antibodies in patients with neuropathy
Girolama Alessandra MarfiaGiovanni AntoniniGiuseppe CosentinoTiziana RossoGiuseppe LauriaManganelli FioreFrancesca GalliaAngelo Maurizio ClericiDario CocitoDoneddu Pietro EmilianoGuido CavalettiMassimiliano FilostoF. TerenghiEduardo Nobile-orazioClaudia GiannottaEmanuela MorenghiBlesson Punnen SajeevLiberatore Giuseppesubject
0301 basic medicinemedicine.medical_specialtyanti-MAG polyneuropathy; chronic inflammatory demyelinating polyradiculoneuropathy; ELISA; sensitivity; specificity; autoantibodies; case-control studies; enzyme-linked immunosorbent assay; humans; myelin-associated glycoprotein; polyneuropathies; retrospective studiesImmunologyAnti-MAG polyneuropathyEnzyme-Linked Immunosorbent AssaySettore MED/26GastroenterologyPolyneuropathies03 medical and health sciencesSensitivity0302 clinical medicineInternal medicinemedicineHumansImmunology and AllergyIn patientAutoantibodiesRetrospective Studieschronic inflammatory demyelinating polyradiculoneuropathyAnti-MAG polyneuropathy chronic inflammatory demyelinating polyradiculoneuropathybiologybusiness.industryAnti magAnti-MAG polyneuropathy chronic inflammatory demyelinating polyradiculoneuropathy; ELISA; Sensitivity; Specificitymedicine.diseaseAutoantibodieMyelin-Associated GlycoproteinTiter030104 developmental biologyPolyneuropathienervous systemNeurologyCase-Control StudiesElisa testSpecificitybiology.proteinELISANeurology (clinical)AntibodyCase-Control StudiebusinessSensitivity (electronics)Polyneuropathy030217 neurology & neurosurgeryHumandescription
For the diagnosis of anti-MAG polyneuropathy the commercial ELISA manufacturer currently recommends a cut-off of 1000 Bühlmann Titer Units (BTU). We analyzed sera from 80 anti-MAG neuropathy patients and 383 controls (with other neuropathies or healthy controls) to assess the ELISA sensitivity and specificity at different thresholds. A better combination of sensitivity/specificity was found at a threshold >1500 BTU than at >1000 BTU. The best value of specificity was obtained at threshold >7000 BTU. There was a diagnostic grey area between 1500 and 7000 BTU in which the clinical phenotypes as well as electrophysiological studies need to be carefully assessed particularly to differentiate CIDP and anti-MAG neuropathy.
year | journal | country | edition | language |
---|---|---|---|---|
2020-08-01 | Journal of Neuroimmunology |