Search results for " Air"
showing 10 items of 703 documents
Spirometric criteria to diagnose airway obstruction in the elderly: fixed ratio vs. lower limit of normal.
2015
COPD is the most common chronic lung disease. It becomes more prevalent with increasing age but remains under-diagnosed in the elderly. A heated debate concerns the most suitable way to diagnose airway obstruction in this age group. Most COPD guidelines recommend to use a FEV1/FVC of 0.70 as threshold to define an obstructive ventilatory defect. While the use of a 0.70 ratio may be simple, it may result in under-diagnosis of airflow obstruction in young people and over-diagnosis in the elderly due to an age-related decline in pulmonary volumes, especially in FEV1. This might lead to unnecessary use of medications and increased risk of adverse effects. A proposed strategy for reducing the mi…
Expression of versican in large and small airways and parenchima in lungs of non-smokers smokers and COPD patients
2009
Airway distensibility by HRCT decreases with severity of COPD.
2008
HRCT evaluation of bronchial response to deep inspiration in asthma and chronic obstructive pulmonary disease (COPD)
2012
Purpose Methods and Materials Results Conclusion References Personal Information
Experimental conditions for respiration and growth studies of F0 and F1 larval and juvenile European seabass Dicentrarchus labrax
2022
Water parameters in the 2 years before spawning of F0 (08.02.2016-06.03.2018) and during larval and juvenile phase of F1: Larval period until 17.05.2018 (48 dph, 900 dd) and 01.06.2018 (63 dph, ~900 dd) for warm and cold life condition respectively, for the juveniles until 28.09.2018 (180 dph, ~4000 dd) and 12.02.2019 (319 dph, ~5100 dd) for warm and cold conditioned fish respectively. Means ± s.e. over all replicate tanks per condition. Temperature (Temp.), pH (free scale), salinity, oxygen and total alkalinity (TA) were measured weekly in F1 and monthly in F0; sea water (SW) measurements were conducted in 2017 and 2018. Water parameters during larval and early juvenile phase of F0: Larval…
Peñón de la Zorra y Puntal de los Carniceros (Villena, Alicante): Revisión de dos conjuntos de yacimientos campaniformes en el corredor del Vinalopó
2002
En el presente artículo se revisa la información existente sobre dos yacimientos campaniformes del Alto Vinalopó –Peñón de la Zorra y Puntal de los Carniceros–. Su importancia dentro de la investigación en tierras levantinas los ha convertido en una referencia casi obligatoria desde su publicación por parte de J. M. Soler García. In this article is cheked information about two bell beaker sites from Vinalopo Valley –Peñón de la Zorra and Puntal de los Carniceros–. The importance of this archaeological sites of investigation concerning Levante areas have got that these places would be an obligatory reference since the publication by J.M. Soler Garcia.
Grapevine row orientation mediated temporal and cumulative microclimatic effects on grape berry temperature and composition
2021
Abstract Ambient radiation and temperature are global drivers of grapevine growth, grape yield and composition, and wine quality. Knowledge of the implications of vineyard row orientation/microclimate is required for decision-making in current and future macro- and mesoclimates. Temporal and cumulative microclimatic changes, induced by vine row orientation (NS; EW; NE-SW; NW-SE) of vertically trellised Shiraz grapevines, on berry pulp temperature and composition at different ripeness levels were investigated. Berries dynamically gained heat energy relative to: ambient climate/weather; direct canopy wall/bunch irradiance; and berry skin colour development. Berries exposed to direct solar rad…
Indoor Air Quality including Respiratory Viruses
2021
The detection of SARS-CoV-2 in indoor environments is a cause of increasing concern. In this study, three sampling methodologies have been used in order to collect SARS-CoV-2 and 17 other respiratory viruses in indoor air, combined with a new analytical process to analyze respiratory viruses. Different areas of an ophthalmological hospital were investigated for the presence of these airborne viruses. Moreover, indoor air quality (IAQ) parameters (carbon dioxide, CO2; carbon monoxide, CO; nitrogen dioxide, NO2; volatile organic compounds, VOCs; formaldehyde, HCHO; and particulate matter, PM) have been examined to study the relationship between IAQ and airborne viruses. All indoor air and sur…
Red and far-red sun-induced chlorophyll fluorescence as a measure of plant photosynthesis
2015
Remote estimation of Sun-induced chlorophyll fluorescence emitted by terrestrial vegetation can provide an unparalleled opportunity to track spatiotemporal variations of photosynthetic efficiency. Here we provide the first direct experimental evidence that the two peaks of the chlorophyll fluorescence spectrum can be accurately mapped from high-resolution radiance spectra and that the signal is linked to variations in actual photosynthetic efficiency. Red and far red fluorescence measured using a novel airborne imaging spectrometer over a grass carpet treated with an herbicide known to inhibit photosynthesis was significantly higher than the corresponding signal from an equivalent untreated…
Preliminary results about the breath of passive smokers and vapers based on the use of portable air monitoring devices
2016
Abstract Preliminary studies were made on the effect of both, classical smoking and electronic cigarettes (ECs) vaping, based on the quality of the indoor air and the breath of passive smokers. Portable air monitoring devices were used to evaluate carbon monoxide (CO), carbon dioxide (CO2), particulate materials (PM), formaldehyde and volatile organic compounds (VOCs) in indoor air and breath of active and passive smokers and vapers. As preliminary results, it can be observed that the major part of PMs liberated in classical smoking and ECs vaping correspond to the lowest size, which is the most dangerous for human health. However, the number of smallest PMs formed during vaping is around 5…