Search results for " Analytic"

showing 10 items of 1718 documents

Tips on ligand immobilization and kinetic study using surface plasmon resonance.

2016

Surface plasmon resonance (SPR) technique offers a robust label-free approach applicable in various investigations including binding affinity, specificity and kinetics of biological macromolecules (e.g., peptides, proteins and nucleotidase) and small molecules. SPR provides extremely important data on the kinetics and affinity of substances examined, through which bio-specific interaction(s) can be established by the analysis of adsorption of analyte onto the immobilized ligand(s) on a sensor-based analytical system. Due to SPR wide applications in biomedical laboratories, the aim of this editorial is to highlight the importance of SPR in affinity kinetics and ligand immobilization.

AnalyteStereochemistryKineticseducationPharmaceutical Science02 engineering and technology01 natural sciencesGeneral Biochemistry Genetics and Molecular BiologyAnalyteAdsorptionNucleotidaseSurface plasmon resonanceSurface plasmon resonancelcsh:QH301-705.5Ligand immobilizationlcsh:R5-920Chemistry010401 analytical chemistryGeneral Medicine021001 nanoscience & nanotechnologyLigand (biochemistry)Small moleculeCombinatorial chemistry0104 chemical sciencesKinetic studyEditoriallcsh:Biology (General)0210 nano-technologylcsh:Medicine (General)MacromoleculeBioImpacts : BI
researchProduct

Observation of interaction forces by investigation of the influence of eluent additives on the retention behavior of aqueous nanoparticle dispersions…

2020

The investigation and subsequent understanding of the interactions of nanomaterials with components of their surrounding media is important to be able to evaluate both potential use cases as well as potential risks for human health and for the environment. To investigate such interactions, asymmetrical flow field-flow fractionation (AF4) is an interesting analytical tool. This statement grounds on the fact that interactions of the analyte with the membrane and with components of the eluent are crucial for the retention behavior of the analyte within the field-flow fractionation (FFF) channel. Therefore, the investigation of the retention behavior provides an insight in the nature of the int…

AnalyteTime FactorsHofmeister seriesSiloxanesHamaker constantStatic ElectricityElectrolyte010402 general chemistry01 natural sciencesBiochemistryAnalytical Chemistrysymbols.namesakeDynamic light scatteringHumansComputer SimulationParticle SizeAqueous solutionChromatographyChemistryElution010401 analytical chemistryOrganic ChemistryOsmolar ConcentrationWaterGeneral MedicineDynamic Light ScatteringFractionation Field Flow0104 chemical sciencesChemical engineeringsymbolsNanoparticlesPolystyrenesvan der Waals forceJournal of chromatography. A
researchProduct

Rapid assay of resveratrol in red wine by paper spray tandem mass spectrometry and isotope dilution.

2017

A rapid analytical approach for the assay of resveratrol in red wines, based on Paper Spray Mass Spectrometry (PS-MS) and Multiple Reaction Monitoring (MRM) is described. The assay involves the use of the stable isotope dilution method. The analytical parameters calculated analyzing fortified samples confirm the reliability of the proposed approach, with accuracy values about 100%, and LOD and LOQ values calculated at 0.5 and 0.8 μg/mL, respectively. Furthermore, both the recovery, which was quantitative for the analyte, and the reproducibility (RSD%), checked on different days on the same wine, always below 7%, highlighted the consistency of the methodology.

AnalyteWineFood chemistryIsotope dilution010402 general chemistryMass spectrometryTandem mass spectrometry01 natural sciencesQuantitative assayAnalytical ChemistryAmbient mass spectrometryIsotopesTandem Mass SpectrometryStilbenesWineReproducibilityChromatographyPaper sprayIsotopeChemistryMedicine (all)010401 analytical chemistrySelected reaction monitoringGeneral MedicineIsotope dilution0104 chemical sciencesResveratrolStilbeneFood ScienceFood chemistry
researchProduct

Electrochemical pH Control at Gold Nanowires

2018

In this work, interdigitated arrays of nanowire electrodes are used with one array acting as the working electrode while the other is used to generate the required protons. Finite element simulations of the pH control electrodes were performed to provide insight on the generation and subsequent diffusion of protons. This informed the inter-tine spacing of the electrodes used.. This electrochemical pH control method was then used to enable the detection of analytes of interest.

AnalyteWorking electrodeMaterials sciencePhysics::Instrumentation and Detectorsbusiness.industry020209 energy010401 analytical chemistryPh controlNanowire02 engineering and technologypH control gold nanowire heavy metal in situ simulationElectrochemistry01 natural sciencesFinite element method0104 chemical sciencesSettore ING-IND/23 - Chimica Fisica ApplicataPhysics::Plasma PhysicsElectrode0202 electrical engineering electronic engineering information engineeringOptoelectronicsDiffusion (business)business2018 IEEE 18th International Conference on Nanotechnology (IEEE-NANO)
researchProduct

Optimization of instrumental parameters for improving sensitivity of single particle inductively-coupled plasma mass spectrometry analysis of gold

2021

Single particle inductively-coupled plasma mass spectrometry (spICP-MS) is a promising technique for analysis of engineered nanoparticles, whose utilization has increased substantially over the past years. Optimization of instrumental conditions is, however, crucial to improve the sensitivity and precision of nanoparticle (NP) detection. In this study, the influence of ICP-MS instrumental parameters (nebulizer gas flow, plasma radiofrequency-power and sampling depth) on the signal intensity of gold in spICP-MS was evaluated using dispersions of Au NPs and a solution of dissolved gold. The interaction effects of the main factors were found to have a significant effect on the signal intensity…

AnalytemassaspektrometriaMaterials sciencetutkimuslaitteetAnalytical chemistryMass spectrometry01 natural sciencesSignalAnalytical ChemistryIonoptimointi0103 physical sciencesInstrumentationInductively coupled plasma mass spectrometrymatrix effectSpectroscopy010302 applied physicsDetection limit010401 analytical chemistryAtomic and Molecular Physics and Optics0104 chemical sciencesSpICP-MSParticleinstrumental parametersnanoparticlesnanohiukkasetParticle sizeoptimization
researchProduct

Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…

2016

Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …

Analytical chemistry010501 environmental sciences01 natural sciencesHigh-performance liquid chromatographyAnalytical ChemistryAdsorptionColumn chromatographyLimit of DetectionPhase (matter)Sample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsChromatography High Pressure Liquid0105 earth and related environmental sciencesCyclodextrinsChromatographyChemistry010401 analytical chemistryExtraction (chemistry)Solid Phase ExtractionWaterMicroporous materialEquipment DesignSilicon Dioxide0104 chemical sciencesAdsorptionPorosityWater Pollutants ChemicalTalanta
researchProduct

Comprehensive analysis of airborne pesticides using hard cap espresso extraction-liquid chromatography-high-resolution mass spectrometry

2017

A hard cap espresso extraction procedure has been developed to recover airborne pesticides in particulate matter trapped in filters. This extraction step was made for 20s at 72°C and 19bar using 50mL of 20% (v/v) acetonitrile in water. After that, based on NaCl salting out, extracts were concentrated 22 times and analysed by ultra-high performance liquid chromatography - high resolution mass spectrometry. 35 pesticides were evaluated, as a proof of concept, being validated the whole methodology and compared the extraction method with that based on microwave assisted extraction for 20min. In short, the method avoids cross-contamination of samples, it is relatively fast and consumes only 10mL…

Analytical chemistry010501 environmental sciencesMass spectrometry01 natural sciencesBiochemistryMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundEspressoMicrowavesAcetonitrileSolvent extractionChromatography High Pressure Liquid0105 earth and related environmental sciencesAir PollutantsChromatographyPesticide residue010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Pesticide ResiduesGeneral MedicinePesticide0104 chemical scienceschemistrySalting outParticulate MatterJournal of Chromatography A
researchProduct

Evaluation of Thin Film Microextraction for trace elemental analysis of liquid samples using LIBS detection

2021

An analytical methodology based in the combination of Thin Film Microextraction with Laser-induced Breakdown Spectroscopy (TFME-LIBS) was investigated, for the first time, for detection of Cu, Cr, Ni and Pb in aqueous solutions. In this methodology, the analytes were extracted in a thin film of adsorbent material deposited on a solid support, which was introduced in the sample to analyse. After extraction, the analytes retained in the adsorbent were analysed by LIBS. In order to obtain adsorbent films useful for the microextraction step, two different experimental procedures for film generation, denoted as Drop Casting Deposition and Mould Deposition, were evaluated. In both cases, graphene…

Analytical chemistryOxide02 engineering and technology01 natural sciencesAnalytical Chemistrylaw.inventionchemistry.chemical_compoundAdsorptionlawDeposition (phase transition)Thin filmGraphene oxideDetection limitLIBSChemistryGraphene010401 analytical chemistryExtraction (chemistry)Trace analysis021001 nanoscience & nanotechnology0104 chemical sciencesLiquid samplesElemental analysisThin Film MicroextractionQuímica Analítica0210 nano-technology
researchProduct

Detection of fluorine using laser-induced breakdown spectroscopy and Raman spectroscopy

2017

In general, the detection of F and other halogens is challenging through conventional techniques. In this paper, various approaches for the qualitative and quantitative analysis of F using the laser-induced breakdown spectroscopy (LIBS) technique were demonstrated. In LIBS, fluorine detection can be realized by means of atomic lines and molecular bands. For the purposes of our experiment, two sets of pellets with various contents of CaF2, CaCO3 and cellulose were analyzed using a lab-based LIBS system under a He atmosphere. The fluorine atomic line at 685.60 nm was correlated with CaF signals proving their close relationship. Consequently, the limits of detection were determined for both an…

Analytical chemistrychemistry.chemical_element02 engineering and technology01 natural sciencesAnalytical ChemistryCrystalsymbols.namesakefluorineLaser-induced breakdown spectroscopySpectroscopySpectroscopyDetection limitChemistry010401 analytical chemistryta1182021001 nanoscience & nanotechnologyfluori0104 chemical scienceslaser-induced breakdown spectroscopyHalogenRaman spectroscopysymbolsFluorine0210 nano-technologyRaman spectroscopyQuantitative analysis (chemistry)
researchProduct

Ultraviolet Filters in Cosmetics

2018

Abstract UV filters are used in sunscreen cosmetics to protect skin from the sunlight. Nowadays, they are also incorporated into other daily-use cosmetics. However, many concerns about their safety have been raised, because they can be absorbed through the skin, further metabolized and eventually bioaccumulated and/or excreted. These percutaneous absorption processes may result in various adverse health effects (i.e., allergic contact dermatitis) and other more serious systemic effects, such as carcinogenic and oestrogenic activity. For this reason, UV filters as well as their maximum allowed concentrations have been regulated by the legislations in force. In this sense, analytical control …

Analytical controlTraditional medicinebusiness.industrymedia_common.quotation_subject010401 analytical chemistrymedicine.diseasemedicine.disease_cause01 natural sciencesCosmetics0104 chemical sciences030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineAdverse health effectPercutaneous absorptionmedicinebusinessAllergic contact dermatitisUltravioletmedia_common
researchProduct