Search results for " Aorta"

showing 10 items of 185 documents

Transpulmonary cardiac output measurement in a rat model of cardiac arrest and CPR: Impact of vascular access

2009

Objective: The present study investigated the impact of the vascular access site for cardiac output (CO) measurement by thermodilution on survival and neurohistopathological injury in a rat model of cardiac arrest (CA) and cardiopulmonary resuscitation (CPR). Secondary the influence of the vascular access site on cardiac output measurements was examined. Methods: Rats underwent asphyxial CA and CPR. Thermocouple probes were either placed via the femoral artery into the bifurcation of abdominal aorta/iliac artery (Femoral) or via the carotid artery into the aortic arch (Carotid). CPR was initiated after 9 min CA. Local cerebral blood flow (lCBF) and CO were assessed for 120 min after restora…

MaleAortic archCardiac outputmedicine.medical_treatmentHemodynamicsFemoral arteryEmergency NursingRats Sprague-Dawleymedicine.arteryIntensive caremedicineAnimalsCardiopulmonary resuscitationCardiac Outputbusiness.industryAbdominal aortaCardiopulmonary ResuscitationHeart ArrestRatsDisease Models AnimalCerebral blood flowAnesthesiaHeart Function TestsEmergency MedicineCardiology and Cardiovascular MedicinebusinessResuscitation
researchProduct

Influence of operative strategy for the aortic arch in DeBakey type I aortic dissection: Analysis of the German Registry for Acute Aortic Dissection …

2012

Objective Patients treated with an extensive approach including total aortic arch replacement for acute aortic dissection type A may have a favorable long-term prognosis by treating the residual false lumen. Our goal was to analyze the operative strategy for treatment of type I DeBakey aortic dissection from the German Registry for Acute Aortic Dissection Type A (GERAADA) data. Methods A total of 658 patients with type I DeBakey aortic dissection and entry only in the ascending aorta were identified in the GERAADA. Patients in group A underwent replacement of the ascending aorta with hemiarch replacement. Patients in group B received extensive treatment with total arch replacement or conven…

MaleAortic archPulmonary and Respiratory Medicinemedicine.medical_specialtyTime FactorsElephant trunksRisk AssessmentGroup Blaw.inventionBlood Vessel Prosthesis ImplantationPostoperative ComplicationsAneurysmRisk FactorslawGermanymedicine.arteryInternal medicineAscending aortamedicineHumansRegistriesAgedAortic dissectionbusiness.industryPerioperativeMiddle Agedmedicine.diseaseIntensive care unitAortic AneurysmSurgeryAortic DissectionLogistic ModelsTreatment OutcomeAcute DiseaseCardiologyFemaleSurgerybusinessCardiology and Cardiovascular MedicineThe Journal of Thoracic and Cardiovascular Surgery
researchProduct

Mid-term results of zone 0 thoracic endovascular aneurysm repair after ascending aorta wrapping and supra-aortic debranching in high-risk patients

2017

Objectives Surgical repair of aneurysmal disease involving the ascending aorta, aortic arch and eventually the descending aorta is generally associated with significant morbidity and mortality. A less invasive approach with the ascending wrapping technique (WT), supra-aortic vessel debranching (SADB) and thoracic endovascular aneurysm repair (TEVAR) in zone 0 was developed to reduce the associated risk in these patients. Methods During a 10-year period, consecutive patients treated by the ascending WT, SADB and TEVAR in zone 0 were included. All patients were considered at high risk for conventional surgery. Measured outcomes included perioperative deaths and morbidity, maximal aortic trans…

MaleAortic archTime FactorsComputed Tomography AngiographyAneurysm; Arch; Ascending; Debranching; TEVAR; Wrapping; Surgery; Pulmonary and Respiratory Medicine; Cardiology and Cardiovascular Medicinemedicine.medical_treatmentWrapping030204 cardiovascular system & hematologyEndovascular aneurysm repairPostoperative Complications0302 clinical medicineRisk FactorsAscendingThoracic aorta030212 general & internal medicineAortaAged 80 and overTEVAR10042 Clinic for Diagnostic and Interventional RadiologyEndovascular ProceduresMiddle Aged2746 SurgeryItalyDescending aortaCardiologyFemaleCardiology and Cardiovascular MedicinePulmonary and Respiratory Medicinemedicine.medical_specialty10216 Institute of Anesthesiology610 Medicine & healthArch2705 Cardiology and Cardiovascular Medicine03 medical and health sciencesAneurysmBlood vessel prosthesismedicine.arteryInternal medicineAscending aortamedicineHumansAgedAortaAortic Aneurysm Thoracicbusiness.industryDebranchingmedicine.diseaseAneurysmBlood Vessel ProsthesisSurgery10020 Clinic for Cardiac Surgery2740 Pulmonary and Respiratory MedicineSurgeryMorbiditybusinessFollow-Up Studies
researchProduct

Thoracic Aortic Intima-Media Thickness in Preschool Children Born Small for Gestational Age

2018

To assess thoracic aortic intima-media thickness (aIMT) as a marker of thoracic aortic remodeling in children born small for gestational age (SGA).We assessed thoracic aIMT, carotid intima-media thickness (cIMT), and pulse wave velocity (PWV) in 239 patients (117 SGA; 122 appropriate for gestational age controls) age 6-8 years. Each SGA participant was matched 1:1 based on sex, gestational age, and birth date. Thoracic aIMT was determined by 2-dimensional transthoracic echocardiography.SGA children showed a significant increase in both aIMT (0.89 mm [0.12] vs 0.79 mm [0.11], P  .001) and cIMT (.50 mm [0.05] vs 0.49 mm [0.04], P  .001) compared with appropriate for gestational age controls, …

MaleAortic archmedicine.medical_specialtyAortic DiseasesAorta ThoracicGestational AgePulse Wave AnalysisCarotid Intima-Media Thickness03 medical and health sciences0302 clinical medicine030225 pediatricsmedicine.arteryInternal medicineHumansMedicineThoracic aorta030212 general & internal medicineChildPulse wave velocitybusiness.industryVascular diseaseInfant NewbornGestational agemedicine.diseaseAortic intimaIntima-media thicknessCase-Control StudiesChild PreschoolInfant Small for Gestational AgePediatrics Perinatology and Child Healthcardiovascular systemCardiologySmall for gestational ageFemalebusinessThe Journal of Pediatrics
researchProduct

A New Off-Pump Hybrid Open and Endovascular Repair to Treat Ductus Botalli and Ascendens Aneurysms

2012

To report a combined ascending aorta and aortic arch hybrid repair, we performed off-pump with no aortic graft replacement. A 65-year-old man, developing progressive recurrent laryngeal nerve paralysis, underwent a computed tomography (CT) angiography detecting nonpatent residual ductus Botalli aneurysm and ascending aorta aneurysm. Due to severe multimorbidities, a less-invasive alternative was elaborated. In a first step, appropriate proximal landing zone for aortic stent grafting was achieved by ascending aorta diameter reduction, with epiaortic wrapping, and debranching the supra-aortic trunks. In the second step, endovascular stent grafts were deployed from proximal ascending aorta to…

MaleAortic archmedicine.medical_specialtyAortographymedicine.medical_treatment610 Medicine & healthAorta ThoracicAortographySettore MED/22 - Chirurgia Vascolare2705 Cardiology and Cardiovascular MedicineBlood Vessel Prosthesis ImplantationAortic aneurysmAneurysmmedicine.arteryAscending aortamedicineHumansThoracic aortacardiovascular diseasesDuctus Arteriosus PatentAgedCardiopulmonary Bypassmedicine.diagnostic_test10042 Clinic for Diagnostic and Interventional Radiologybusiness.industryEndovascular Proceduresaortic arch aortic operation carotid afteries endovascular procedures vascular diseaseStentGeneral Medicinemedicine.disease10020 Clinic for Cardiac Surgery2746 SurgeryAortic AneurysmSurgeryTreatment Outcomesurgical procedures operativeDescending aortacardiovascular systemSurgeryRadiologyTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessVascular and Endovascular Surgery
researchProduct

Role of Transesophageal Echocardiography in Dissection of the Aorta and Evaluation of Degenerative Aortic Disease

1993

The combination of different ultrasound techniques such as transthoracic, suprasternal, subcostal, and TEE has a high sensitivity and specificity in the diagnosis of aortic dissection. Limitations of this combined ultrasound technique are related to the visualization of the ascending part of the aortic arch, which, because of the interposition of the trachea, cannot be visualized completely. The beginning or end of a dissection in this part of the aorta may be misinterpreted. However, false-negative results are rare. False-positive results due to artifacts resulting from reverberations in an ectatic ascending aorta must be taken into account. The most important diagnostic goals in acute or …

MaleAortic archmedicine.medical_specialtyArteriosclerosisAortic DiseasesSensitivity and SpecificityCoronary artery diseaseAneurysmInternal medicinemedicine.arteryAscending aortamedicineHumansAortaAgedAortic dissectionAortabusiness.industryGeneral Medicinemedicine.diseaseAortic AneurysmAortic DissectionOstiumDescending aortaCardiologyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessEchocardiography TransesophagealCardiology Clinics
researchProduct

Cross-clamping a porcelain aorta: an alternative technique for high-risk patients

2018

Background Aortic cross-clamping in patients with porcelain aorta is associated with high mortality and morbidity rates. The aim is to establish a new approach to improve the outcome in this high-risk population. Methods Between September 2007 and November 2012, 42 patients with an aortic (N.=33; 81.3±6.4 years) or mitral valve disease (N.=9; 80.3±5.7) combined with a porcelain aorta underwent aortic (AVR) or mitral valve replacement (MVR). After arterial cannulation via distal aortic arch or femoral artery, longitudinal aortotomy under total cardiopulmonary bypass (CPB) was performed. The aorta was slowly clamped, thus mobilized atherosclerotic material could leave the aorta through the op…

MaleAortic archmedicine.medical_specialtyTime Factorsmedicine.medical_treatmentOperative TimePopulationAortic DiseasesHeart Valve Diseases030204 cardiovascular system & hematologylaw.invention03 medical and health sciencesPostoperative Complications0302 clinical medicineRisk Factorslawmedicine.arteryInternal medicineMitral valveAscending aortaCardiopulmonary bypassHumansMedicineVascular CalcificationeducationStrokeAgedRetrospective StudiesAged 80 and overHeart Valve Prosthesis Implantationeducation.field_of_studyAortaCardiopulmonary Bypassbusiness.industryMitral valve replacementGeneral Medicinemedicine.diseaseConstrictionTreatment Outcomemedicine.anatomical_structure030228 respiratory systemAortic Valvecardiovascular systemCardiologyMitral ValveFemaleSurgeryCardiology and Cardiovascular MedicinebusinessThe Journal of Cardiovascular Surgery
researchProduct

Carotid artery stenting with contralateral carotid occlusion in a rare aortic arch configuration

2010

We present the case of a 47-year-old man admitted to our department with an episode of aphasia. Duplex scan showed an occluded right internal carotid artery and severe left internal carotid artery stenosis. Contrast-enhanced computer tomography demonstrated a common trunk for both common carotid arteries anterior to the trachea and aberrant right subclavian artery posterior to the esophagus. The patient was considered to be a high risk for carotid endarterectomy and, consequently, we performed stenting of the left carotid artery. To our knowledge, this is the first case reporting the combination of these two aortic arch anomalies and the concomitant endovascular treatment of atherosclerotic…

MaleAortic archmedicine.medical_specialtyVascular Malformationsmedicine.medical_treatmentCarotid arteriesCarotid StenosiSubclavian ArteryAorta ThoracicCarotid endarterectomySettore MED/22 - Chirurgia Vascolaremedicine.arteryInternal medicineStentcarotid artery disease aortic arch anomalies carotid stenting contralateral occlusionmedicinecarotid occlusionHumansThoracic aortaCarotid Stenosiscardiovascular diseasesEsophagusaortic arch anomalieSubclavian arteryUltrasonography Doppler DuplexVascular Malformationcarotid artery stentingbusiness.industryMedicine (all)General MedicineMiddle Agedmedicine.diseaseStenosisTreatment Outcomemedicine.anatomical_structureConcomitantcardiovascular systemCardiologyStentsTomography X-Ray ComputedCardiology and Cardiovascular MedicinebusinessAngioplasty BalloonCarotid Artery InternalHumanJournal of Cardiovascular Medicine
researchProduct

Fiber Micro-Architecture in the Longitudinal-Radial and Circumferential-Radial Planes of Ascending Thoracic Aortic Aneurysm Media.

2013

It was recently demonstrated by our group that the delamination strength of ascending thoracic aortic aneurysms (ATAA) was lower than that of control (CTRL, non-aneurysmal) ascending thoracic aorta (ATA), and the reduced strength was more pronounced among bicuspid (BAV) vs. tricuspid aortic valve (TAV) patients, suggesting a different risk of aortic dissection for BAV patients. We hypothesized that aortic valve morphologic phenotype predicts fiber micro-architectural anomalies in ATA. To test the hypothesis, we characterized the micro-architecture in the longitudinal-radial (Z-RAD) and circumferential-radial (Θ-RAD) planes of human ATA tissue that was artificially dissected medially. The ou…

MaleAortic valve030204 cardiovascular system & hematology0302 clinical medicineThoracic aortaOrthopedics and Sports MedicineHuman ascending thoracic aortic aneurysmAortic dissection0303 health sciencesbiologyDissectionRehabilitationAnatomyMiddle AgedTunica intimaBiomechanical Phenomenamedicine.anatomical_structureAortic Valvecardiovascular systemCardiologyFemaleCollagenTunica Mediamedicine.medical_specialtyMicro-architectureMaterials scienceAortic RuptureBiomedical EngineeringBiophysicsDissection (medical)Multi-photon microscopyThoracic aortic aneurysmArticle03 medical and health sciencesInternal medicinemedicine.arterymedicineHumansAortic rupture030304 developmental biologyAnalysis of VarianceAortic Aneurysm ThoracicPhenolmedicine.diseaseElastinAortic DissectionMicroscopy Fluorescence Multiphotonbiology.proteinTunica IntimaElastin
researchProduct

CONNEXIN43 GAP JUNCTION LEVELS DURING DEVELOPMENT OF THE THORACIC AORTA ARE TEMPORALLY CORRELATED WITH ELASTIC LAMINAE DEPOSITION AND INCREASED BLOOD…

1997

A characteristic property of the vascular smooth muscle cell is its ability to modulate between a contractile phenotype, responsible for control of vascular tone, through to a synthetic phenotype, capable of migration and synthesis of extracellular matrix molecules. Smooth muscle cells are coupled by gap junctions, the membrane structures which permit direct intercelluar passage of ions and small molecules, and which play a role both in electrical coupling and intercellular communication during patterning and development. We have previously found that connexin43 type gap junction expression is upregulated in the synthetic phenotype smooth muscle cell in vitro and during atherosclerotic plaq…

MaleCell signalingVascular smooth muscleAorta ThoracicBlood PressureCell CommunicationMuscle Smooth VascularRats Sprague-Dawleymedicine.arterymedicineAnimalsThoracic aortaAortaChemistryCell growthGap junctionGap JunctionsCell BiologyGeneral MedicineAnatomyPhenotypeRatsCell biologyConnexin 43FemaleIntracellularCell Biology International
researchProduct