On the use of the absorbed depth-dose measurements in the beam calibration of a surface electronic high-dose-rate brachytherapy unit, a Monte Carlo-b…
2019
PURPOSE To evaluate the use of the absorbed depth-dose as a surrogate of the half-value layer in the calibration of a high-dose-rate electronic brachytherapy (eBT) equipment. The effect of the manufacturing tolerances and the absorbed depth-dose measurement uncertainties in the calibration process are also addressed. METHODS The eBT system Esteya® (Elekta Brachytherapy, Veenendaal, The Netherlands) has been chosen as a proof-of-concept to illustrate the feasibility of the proposed method, using its 10 mm diameter applicator. Two calibration protocols recommended by the AAPM (TG-61) and the IAEA (TRS-398) for low-energy photon beams were evaluated. The required Monte Carlo (MC) simulations w…
WE-C-108-08: Organ Doses in a Male Phantom Undergoing High-Dose-Rate Brachytherapy Applied to the Prostate
2013
Purpose: The aim of this study was to obtain equivalent doses to radiosensitive organs when applying high‐dose‐rate (HDR) brachytherapy to the prostate using60 Co or 192 Ir sources, and in comparison to external‐beam radiotherapy (EBRT) modalities. Methods: Monte Carlo simulations in Geant4 were performed using a voxelized adult reference man described in Publication 110 by the International Commission on Radiological Protection (ICRP). Point sources of 60Co or 192Ir with photon energy spectra corresponding to those exiting their capsules were placed in the center of the prostate. Equivalent doses per therapeutic absorbed dose to the prostate were obtained in several radiosensitive organs. …
Braquiterapia en el cáncer de labio
2006
El cáncer de labio es de los más prevalentes entre los tumores cutáneos de cabeza y cuello. Las características del tumor, por su crecimiento exofítico en una zona de fácil acceso visual, permite un diagnóstico en estadios incipientes y, por tanto, un mejor pronóstico con los actuales tratamientos. En estadios iniciales se puede realizar tratamiento con cirugía o braquiterapia, siendo los resultados similares en cuanto al control local; sin embargo la braquiterapia ofrece mejores resultados estéticos y funcionales. Presentamos un trabajo de revisión bibliográfica al respecto de de las indicaciones, técnicas y resultados de la braquiterapia en el cáncer de labio. Lip cancer is one of the mos…
Dosimetric evaluation of internal shielding in a high dose rate skin applicator
2011
Purpose: The Valencia HDR applicators are accessories of the microSelectron HDR afterloading system (Nucletron) shaped as truncated cones. The base of the cone is either 2 or 3 cm diameter. They are intended to treat skin lesions, being the typical prescription depth 3 mm. In patients with eyelid lesions, an internal shielding is very useful to reduce the dose to the ocular globe. The purpose of this work was to evaluate the dose enhancement from potential backscatter and electron contamination due to the shielding. Material and methods: Two methods were used: a) Monte Carlo simulation, performed with the GEANT4 code, 2 cm Valencia applicator was placed on the surface of a water phantom in …
Technical note: Dosimetric study of a new Co-60 source used in brachytherapy
2007
The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.
SU-FF-T-41: Monte Carlo Dosimetric Study of the New BEBIG Co-60 HDR Source
2005
Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Plannin…
Interobserver study of countouringbased on ultrasound image in real-time interactive prostate brachytherapy
2009
Die kombinierte operative und radiotherapeutische Behandlung (CORT) von Beckenwandrezidiven: Erfahrungsbericht nach 3 Jahren
1993
CORT has been developed to treat recurrent gynaecological malignancies infiltrating the pelvic wall unilaterally. The surgical part consists of: (i) staging laparotomy/lymphadenectomy, (ii) maximum tumour resection at the pelvic wall and exenteration of infiltrated central pelvic organs, (iii) implantation of guiding tubes on the residual tumour/tumour bed on the pelvic wall, (iv) pelvic wall plasty with muscle, musculocutaneous and omentum flaps, (v) operative reconstruction of bowel, bladder and perineo-vulvo-vaginal functions. Radiation is performed as interstitial high dose rate brachytherapy through the implanted tubes. Patients without prior pelvic irradiation receive in addition, who…
Failure mode and effects analysis of skin electronic brachytherapy using Esteya® unit
2016
Purpose: Esteya® (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden) is an electronic brachytherapy device used for skin cancer lesion treatment. In order to establish an adequate level of quality of treatment, a risk analysis of the Esteya treatment process has been done, following the methodology proposed by the TG-100 guidelines of the American Association of Physicists in Medicine (AAPM). Material and methods: A multidisciplinary team familiar with the treatment process was formed. This team developed a process map (PM) outlining the stages, through which a patient passed when subjected to the Esteya treatment. They identified potential failure modes (FM) and each individual FM…
GEC-ESTRO ACROP recommendations on calibration and traceability of LE-LDR photon-emitting brachytherapy sources at the hospital level
2019
Prostate brachytherapy treatment using permanent implantation of low-energy (LE) low-dose rate (LDR) sources is successfully and widely applied in Europe. In addition, seeds are used in other tumour sites, such as ophthalmic tumours, implanted temporarily. The calibration issues for LE-LDR photon emitting sources are specific and different from other sources used in brachytherapy. In this report, the BRAPHYQS (BRAchytherapy PHYsics Quality assurance System) working group of GEC-ESTRO, has developed the present recommendations to assure harmonized and high-quality seed calibration in European clinics. There are practical aspects for which a clarification/procedure is needed, including aspect…