Search results for " Bone"

showing 10 items of 933 documents

Murine model of interstitial cytomegalovirus pneumonia in syngeneic bone marrow transplantation: persistence of protective pulmonary CD8-T-cell infil…

2000

ABSTRACTInterstitial pneumonia (IP) is a severe organ manifestation of cytomegalovirus (CMV) disease in the immunocompromised host, in particular in recipients of bone marrow transplantation (BMT). Diagnostic criteria for the definition of CMV-IP include clinical evidence of pneumonia together with CMV detected in bronchoalveolar lavage or lung biopsy. We have used the model of syngeneic BMT and simultaneous infection of BALB/c mice with murine CMV for studying the pathogenesis of CMV-IP by controlled longitudinal analysis. A disseminated cytopathic infection of the lungs with fatal outcome was observed only when reconstituting CD8 T cells were depleted. Neither CD8 nor CD4 T cells mediated…

ImmunologyPneumonia ViralBiologyCD8-Positive T-LymphocytesLymphocyte ActivationMicrobiologyPathogenesisMiceVirologyImmunopathologymedicineCytotoxic T cellAnimalsHumansLungBone Marrow TransplantationMice Inbred BALB CLungmedicine.diagnostic_testSyngeneic Bone Marrow TransplantationDisease Models AnimalTransplantation Isogeneicmedicine.anatomical_structureBronchoalveolar lavagePhenotypeViral replicationInsect ScienceImmunologyCytomegalovirus InfectionsPathogenesis and ImmunityFemaleLung Diseases InterstitialCD8Journal of virology
researchProduct

Vertical Osteoconductive Characteristics of Titanium Implants with Calcium-Phosphate-Coated Surfaces - A Pilot Study in Rabbits

2014

Introduction: Osteoconductive characteristics of different implant surface coatings are in the focus of current interest. The aim of the present study was to compare the vertical osteoconductivity at the implant shoulder of supracrestal inserted calcium-phosphate coated implants (SLA-CaP) with conventional sand-blasted/acid-etched (SLA) implants in a rabbit model. Materials and Methods: SLA-CaP and SLA implants were inserted bilaterally in the mandible of four rabbits in a split-mouth design. The implants were placed 2 mm supracrestal. After 3 weeks, at the left and right implant shoulder, the percentage of linear bone fill (PLF) as well as bone-implant contact (BIC-D) were determined. Resu…

Implant surfacebusiness.industryfungiMandibleDentistrychemistry.chemical_elementOsseointegrationchemistryRabbit modelMedicineWoven BoneImplantOral SurgeryBone heightbusinessGeneral DentistryTitaniumClinical Implant Dentistry and Related Research
researchProduct

Effect of platform switching on the peri-implant bone: A finite element study

2015

Background: There exists a relation between the presence and location of the micro-gap and the loss of peri-implant bone. Several authors have shown that the treatments based on the use of platform switching result in less peri-implant bone loss and an increased tissue stability. The purpose of this study was to analyse the effect of the platform switching on the distribution of stresses on the peri-implant bone using the finite element method. Material and Methods: A realistic 3D full-mandible finite element model representing cortical bone and trabecular bone was used to study the distribution of the stress on the bone induced by an implant of diameter 4.1 mm. Two abutments were modelled.…

Implantes dentalesMaterials scienceResearchOsteólisisPlatform switchingOdontologíaPeri implant bone:CIENCIAS MÉDICAS [UNESCO]BioinformaticsCiencias de la saludFinite element methodFinite element studyMasticatory forceStress (mechanics)medicine.anatomical_structureUNESCO::CIENCIAS MÉDICASmedicineCortical boneImplantImplantologyGeneral DentistryBiomedical engineeringJournal of Clinical and Experimental Dentistry
researchProduct

Effect of bone loss on the fracture resistance of narrow dental implants after implantoplasty. An in vitro study

2021

Background Implantoplasty (IP) involves polishing of the exposed surface of implants affected by peri-implantitis (PI). A study was made to determine whether the degree of bone loss influences the fracture resistance of implants with or without IP. Material and Methods An in vitro study was carried out on 32 narrow (3.5 mm) dental implants with a rough surface and external hexagonal connection. Implantoplasty was performed in half of the implants of the sample. Both the IP and control implants were divided into two subgroups according to the amount of bone loss (3 mm or 7.5 mm). Standardized radiographic assessment of implant width was performed using specific software. The main outcome var…

ImplantoplastyMaterials scienceRadiographyAlveolar Bone LossCirurgia dentalDentistryCompressive strengthOutcome variableHumansIn vitro studycancerPeri-implantitisGeneral DentistryUNESCO:CIENCIAS MÉDICASTraumatismes dentalsTitaniumjaw boneDental traumaImplants dentalsHexagonal crystal systembusiness.industryResearchDental implantsTitaniOtorhinolaryngologyoral metastasesRough surfaceDental surgeryFracture (geology)incidenceSurgeryStress MechanicalImplantbusinesssoft tissueImplantology
researchProduct

BONE AND JOINT MANIFESTATIONS IN PATIENTS AFFECTED BY INFLAMMATORY BOWEL DISEASE.

2011

Onset of the symptoms in patients with ulcerative colitis and Crohn's disease is sometimes characterized by osteoarticular manifestations. The usual presentation of peripheral arthritis is asymmetric, polyarticular and migrant, often involving large joints of the upper and lower limbs, unlike rheumatoid arthritis. This study analyses the statistical incidence of arthritic manifestations in elderly patients with inflammatory bowel disease.

Inflammatory Bowel Disease IBD Bone and Joint manifestations.
researchProduct

Design characteristics, primary stability and risk of fracture of orthodontic mini-implants: Pilot scan electron microscope and mechanical studies

2013

Objectives: Orthodontic mini-implants (OMIs) are increasingly used in orthodontics but can fail for various reasons. This study investigates the effects of OMI design characteristics on the mechanical properties in artificial bone. Material and Methods: Twelve self-drilling OMIs (2 small, 6 medium, 4 large) from 8 manufacturers were tested for their primary stability in simulated medium-high cancellous bone and the risk to fracture in high-density methacrylate blocks. For the assessments of the maximum insertion torque (IT) and torsional fracture (TF) 5 of each OMI were used and for the pull-out strength (POS) 10. The OMIs were inserted with a torque screwdriver (12 sec/360°) until the bott…

Insertion torqueDental Stress Analysisprimary stabilityArtificial boneMaterials scienceorthodontic mini-implantsTorsion MechanicalOdontologíatorsional fractureProsthesis Designpullout strengthDesign characteristicslaw.inventionMecànica de fracturalawRisk FactorsMaterials TestingBiomaterials and Bioengineering in DentistrymedicineOrthodontic Anchorage ProceduresFracture mechanicsGeneral Dentistry:Enginyeria dels materials::Desgast de materials [Àrees temàtiques de la UPC]Implants artificialsTorsion (mechanics)Implants ArtificialPullout strength:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludProsthesis Failuremedicine.anatomical_structureOtorhinolaryngologyMini implantsUNESCO::CIENCIAS MÉDICASMicroscopy Electron ScanningSurgeryResearch-ArticleElectron microscopeCancellous boneinsertion torqueBiomedical engineering
researchProduct

Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency an…

2020

Background This study aimed to evaluate the effect of the implant design and the presence of cortical bone in the primary stability, as well as analyze the differences between the stability measurements obtained by two different resonance frequency analysis (RFA) devices. Material and methods A total of 80 Klockner implants of two different models [40 Essential Cone implants (group A) and 40 Vega implants (group B)] were used. The implants were placed in two polyurethane blocks that simulated the mechanical properties of the maxillary bone. One block featured a layer of cortical bone that was absent from the other block. The primary stability of all implants was measured by insertion torque…

Insertion torqueMaterials scienceResearch0206 medical engineeringImplant design030206 dentistry02 engineering and technology:CIENCIAS MÉDICAS [UNESCO]020601 biomedical engineering03 medical and health sciencesResonance frequency analysis0302 clinical medicinemedicine.anatomical_structureCoronal planeUNESCO::CIENCIAS MÉDICASmedicineIn vitro studyCortical boneImplantOral SurgeryGeneral DentistryBiomedical engineering
researchProduct

Two new species of the genusBatropetes(Tetrapoda, Lepospondyli) from the Central European Rotliegend (basal Permian) in Germany

2015

ABSTRACTTwo new species of Batropetes are described from the Lower Rotliegend of the Saar-Nahe Basin in western Germany. Batropetes palatinus, sp. nov., is characterized by a narrow, anteriorly elongated prefrontal, a slender postfrontal without an anterolateral process, a trapezoid postorbital, and a large quadrate in exterior view. Batropetes appelensis, sp. nov., is characterized by a high angular, ‘Z’-shaped angular-dentary suture, no indentation between stem and plate of interclavicle, and scapulocoracoid without ossified coracoid. The genus Batropetes is characterized by an average length of almost 8 cm, a short trunk with 17 or 19 presacrals depending on the species, large orbit with…

InterclaviclePaleontologybiologyPermianQuadrate boneForamenPaleontologyScapulocoracoidLepospondyliAnatomybiology.organism_classificationBatropetesCoracoidJournal of Vertebrate Paleontology
researchProduct

A new implant-abutment connection for bacterial microleakage prevention: An in vitro study

2017

Purpose The aim of our study is to evaluate the ability of a new type of implant (Konus Implant System®, Industrie biomediche e farmaceutiche, Italy) to isolate the internal of an implant-abutment connection from the external environment. Materials and methods To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Results Bacteria were detected inside all studied implants, with a median…

Internal spaceBacterial leakageDentistryBone resorptionImplant dentistry03 medical and health sciences0302 clinical medicineMedicineTannerella forsythiaIn vitro studyGeneral Dentistrybiologybusiness.industryImplant dentistryBacterial leakage030206 dentistrybiology.organism_classificationBacterial leakage; Bone resorption; Implant dentistry; Implant-abutmentconnection; Perimplantitis; Dentistry (all)Dentistry (all)ImplantbusinessAbutment (dentistry)PerimplantitisImplant abutment030215 immunologyImplant-abutmentconnection
researchProduct

Radiofrequency ablation of osteoid osteoma

2018

Osteoid osteoma is a benign bone neoplasm with a reported incidence of 2-3% among all bone primary tumors. Although it is a small and benign lesion, it is often cause of patient complaint and discomfort. It is generally characterized by a long lasting, unremitting pain that typically exacerbates at night, often leading to sleep deprivation and functional limitation of the skeletal segment involved, with a significant reduction of patient daily life activities and consequent worsening of the overall quality of life. Over decades, complete surgical resection has represented the only curative treatment for symptomatic patients. In the last years, new percutaneous ablation techniques, especiall…

Interventional radiology Osteoid Osteoma Bone tumors Radiofrequency ablationbone tumorsRadiofrequency AblationImaging Three-Dimensionalinterventional radiologyOsteoma OsteoidHumansBone NeoplasmsReviewMagnetic Resonance Imaging InterventionalRadiography Interventionalosteoid osteomaActa bio-medica : Atenei Parmensis
researchProduct