Search results for " CT"
showing 10 items of 306 documents
Probabilistic inference of approximations
2006
We consider probabilistic inductive inference of Godel numbers of total recursive functions when the set of possible errors is allowed to be infinite, but with bounded density. We have obtained hierarchies of classes of functions identifiable with different probabilities up to sets with fixed density. The obtained hierarchies turn out to be different from those which we have in the case of exact identification.
Reflexions about imaging technique and examination protocol
2004
Computed tomography as imaging technique is established since decades, especially in examinations of the orbit. New technical development of multi-slice helical CT requires new attention, concerning radiation burden. Always asked is the use of contrast material in orbital examination. Indications and contraindications are discussed.
Imaging the COVID-19: a practical guide
2021
The Coronavirus Disease 2019 (COVID-19) represents the first medical catastrophe of the new millennium. Although imaging is not a screening test for COVID-19, it plays a crucial role in evaluation and follow-up of COVID-19 patients. In this paper, we will review typical and atypical imaging findings of COVID-19.
Three-dimensional helical CT of the tracheobronchial tree: evaluation of imaging protocols and assessment of suspected stenoses with bronchoscopic co…
1996
To assess the accuracy of three-dimensional (3D) helical CT of normal airways, we evaluated different imaging protocols in test objects and patients. The clinical value of 3D helical CT was composed with bronchoscopy in patients with suspected stenoses, especially before and after endobronchial procedures.Solid test objects--one of central airways and one of peripheral airways--were scanned and assessed for volume defects and stairstep artifacts. Fifty helical studies were performed in 36 patients. We evaluated these images for visualization of segmental bronchi; frequency of artifacts; and presence, localization, and degree of stenoses. Bronchoscopic correlation was available for 40 CT exa…
A rare case of pedunculated bronchial hemangioma
2009
We describe a rare case of pedunculated endobronchial hemangioma observed in a 60 years old patient complaining of chronic productive cough and accessional dyspnea which had been progressively worsening over 20 years. The lesion was first noticed at fiberoptic bronchoscopy; then computed tomography scan was performed and integrated with tridimensional reconstruction techniques. Pathology showed the picture of a vascular neoplasm, compatible with capillary hemangioma. The lesion was submitted to laser-assisted endoscopic removal in order to relieve the obstruction, leading to remission of symptoms.
Efficacy of raw implementation and reduction dose protocols in CT colonoscopy: a single centre 4 years retrospective review
2015
Aims and objectives Methods and materials Results Conclusion Personal information References
Ruolo dell’imaging TC nella valutazione post-mortem dei soggetti deceduti per caduta da altezze elevate: nostra esperienza
2016
The CT-v can therefore be considered an effective method as an aid in the autopsy evaluation of individuals who died for various causes; in particular, in the case of deaths due to accidental falls from high altitudes, is able to identify the primary cause of death and all the epiphenomena due to precipitation.
Digital CZT detector system for high flux energy-resolved X-ray imaging
2017
Photon counting arrays with energy resolving capabilities are recently desired for the next-generation X-ray imaging systems. In this work, we present the performance of a 2 mm thick CZT pixel detector, with pixel pitches of 500 mu m and 250 mu m, coupled to a fast and low noise ASIC (PIXIE ASIC), characterized by only the preamplifier stage. A 16-channel digital readout electronics was used to continuously digitize and process each output channel from the PIXIE ASIC, performing multi-parameter analysis (event arrival time, pulse shape, pulse height) at low and high input counting rates (ICRs). The spectroscopic response of the system to monochromatic X-ray and gamma ray sources, at both lo…
Patients perception of ionising radiation risks in CT ionising exposure. Does dose bill works?
2015
Communicating to patients the magnitude of risk related to ionizing radiation exposure is problematic because of the uncertainty in estimates derived principally from epidemiological studies of large populations [1-6]. Euratom directive 59/2013 requires that dose bill will be part of the radiological report in European Countries [7]. However, how a risk is framed has a profound effect on risk perception. To date, no previous studies evaluated which could be the best way to make patient friendly dose bill. Our aim was to evaluate patients' perception of radiation exposure related to routine CT and their understanding after dose bill.