X-ray response of CdZnTe detectors grown by the vertical Bridgman technique: Energy, temperature and high flux effects
2016
Abstract Nowadays, CdZnTe (CZT) is one of the key materials for the development of room temperature X-ray and gamma ray detectors and great efforts have been made on both the device and the crystal growth technologies. In this work, we present the results of spectroscopic investigations on new boron oxide encapsulated vertical Bridgman (B-VB) grown CZT detectors, recently developed at IMEM-CNR Parma, Italy. Several detectors, with the same electrode layout (gold electroless contacts) and different thicknesses (1 and 2.5 mm), were realized: the cathode is a planar electrode covering the detector surface (4.1×4.1 mm2), while the anode is a central electrode (2×2 mm2) surrounded by a guard-rin…
Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
2017
Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …
Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors
2018
Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…
Simultaneous Determination of Caffeine and Chlorogenic Acids in Green Coffee by UV/Vis Spectroscopy
2017
A simple method for the simultaneous determination of caffeine and chlorogenic acids content in green coffee was reported. The method was based on the use of UV/Vis absorption. It is relevant that the quantification of both caffeine and chlorogenic acids was performed without their preliminary chemical separation despite their spectral overlap in the range 250–350 nm. Green coffee was extracted with 70% ethanol aqueous solution; then the solution was analyzed by spectroscopy. Quantitative determination was obtained analytically through deconvolution of the absorption spectrum and by applying the Lambert-Beer law. The bands used for the deconvolution were the absorption bands of both caffein…
Palmitoylation is a post-translational modification of Alix regulating the membrane organization of exosome-like small extracellular vesicles.
2018
Abstract Background Virtually all cell types have the capacity to secrete nanometer-sized extracellular vesicles, which have emerged in recent years as potent signal transducers and cell-cell communicators. The multifunctional protein Alix is a bona fide exosomal regulator and skeletal muscle cells can release Alix-positive nano-sized extracellular vesicles, offering a new paradigm for understanding how myofibers communicate within skeletal muscle and with other organs. S-palmitoylation is a reversible lipid post-translational modification, involved in different biological processes, such as the trafficking of membrane proteins, achievement of stable protein conformations, and stabilization…
Identification of circumferential regional heterogeneity of ascending thoracic aneurysmal aorta by biaxial mechanical testing
2019
Abstract Ascending thoracic aortic aneurysm (ATAA) in patients with bicuspid aortic valve (BAV) can present an asymmetrical aortic dilatation compared with patients with tricuspid aortic valve (TAV). This pattern of aneurysm dilatation led us to hypothesize that biomechanical differences likely induced by regional heterogeneity of material properties can underlie the observed asymmetric enlargement discrepancies between BAV ATAA and TAV ATAA. This study aimed to characterize the mechanical properties and associated aortic tissue stiffness changes along the circumferential direction of aortic rings collected from surgically-repaired patients with ATAA. Biaxial material testing was performed …
Un barrio marginado no es un barrio marginal. A propósito de Nazaret (Valencia)
2016
This article takes us to Nazaret, an outlying district on Valencia’s waterfront which we consider from three complementary perspectives: the synchronic vision of its current socio-spatial structure, the diachronic and processual contextualization of the changes it has undergone in the last century, and the perceptions and images which characterize the neighbourhood, together with the features, activity and incidence of its associative fabric. The analysis focuses on the behaviour of a set of interconnected factors, including the impact of the port and urban development policy, its socioeconomic make-up, the consistency of its associative fabric and its relations with government. Whereas the…
Photocage-initiated time-resolved solution X-ray scattering investigation of protein dimerization
2018
Photocaging in combination with X-ray solution scattering allows for the time-resolved study of protein dynamics in solution. This method is versatile and allows for accurate triggering of protein function.
Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors
2020
AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…
Intermittent targeted therapies and stochastic evolution in patients affected by chronic myeloid leukemia
2016
Front line therapy for the treatment of patients affected by chronic myeloid leukemia (CML) is based on the administration of tyrosine kinase inhibitors, namely imatinib or, more recently, axitinib. Although imatinib is highly effective and represents an example of a successful molecular targeted therapy, the appearance of resistance is observed in a proportion of patients, especially those in advanced stages. In this work, we investigate the appearance of resistance in patients affected by CML, by modeling the evolutionary dynamics of cancerous cell populations in a simulated patient treated by an intermittent targeted therapy. We simulate, with the Monte Carlo method, the stochastic evolu…