Search results for " Carl"

showing 10 items of 1737 documents

New Capabilities of the FLUKA Multi-Purpose Code

2022

We would like to deeply thank the CERN Knowledge Transfer and Legal Service teams for their essential and extended support. Our appreciation also goes to the FLUKA.CERN Collaboration Board members for their strong commitment.

mallintaminendeuteronComputerSystemsOrganization_COMPUTERSYSTEMIMPLEMENTATIONSingle event effects (SEE)acceleratorQC1-999Materials Science (miscellaneous)beam-matter interactionBiophysicsGeneral Physics and Astronomysingle event effects (see)hiukkasfysiikkamedical physicshigh energy physicsFLUKAbenchmarkcrystal channelingbismuthsimulointiddc:530High energy physicsPhysical and Theoretical ChemistryHardware_REGISTER-TRANSFER-LEVELIMPLEMENTATIONMathematical Physicshiukkassäteilymonte carlo transportflukafacilityPhysicstietokoneohjelmatMonte Carlo transportComputing and Computersddc:Monte Carlo -menetelmätBeam-matter interactionsäteilyfysiikkaCrystal channelingaluminumbeamactivationMedical physicssimulationsParticle Physics - Experimentproton
researchProduct

Insights into the derivative-based method for nonlinear mediation models

2022

Associational mediation analysis has generally relied on the linearity of models to estimate the indirect effect as a product of regression coefficients. Very few examples of generalisations to nonlinear settings have been proposed, including a derivative-based method that, however, is far from being widely spread among scholars. In this paper, we clarify some aspects of such an approach to nonlinear mediation models, which have not been addressed by the previous literature. In addition, we run a simulation study to compare confidence intervals for the indirect effect obtained through different approaches.

mediation analysis derivative method generalised linear models bootstrap Monte Carlo method Bayesian statisticsSettore SECS-S/01 - Statistica
researchProduct

Study of CT/MRI mutual information based registration applied in brachytherapy

2016

The present work aims to include magnetic resonance imaging (MRI) in a Medical Image-based Graphical platfOrm - Brachytherapy module (AMIGOBrachy) which coupled to the Monte Carlo N-Particle (MCNP6) code allows absorbed dose calculations. Computed tomography (CT) and MRI images were registered using mutual information algorithms to improve tissue segmentation potentially leading to a more accurate treatment planning system.

medicine.diagnostic_testbusiness.industrymedicine.medical_treatmentPhysics::Medical PhysicsMonte Carlo methodBrachytherapyImage registrationMagnetic resonance imagingMutual information030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed dosemedicineMedical imagingComputer visionArtificial intelligencebusinessNuclear medicineRadiation treatment planning2016 Global Medical Engineering Physics Exchanges/Pan American Health Care Exchanges (GMEPE/PAHCE)
researchProduct

Translating cross-lagged effects into incidence rates and risk ratios: The case of psychosocial safety climate and depression

2017

Longitudinal studies are the gold standard of empirical work and stress research whenever experiments are not plausible. Frequently, scales are used to assess risk factors and their consequences, and cross-lagged effects are estimated to determine possible risks. Methods to translate cross-lagged effects into risk ratios to facilitate risk assessment do not yet exist, which creates a divide between psychological and epidemiological work stress research. The aim of the present paper is to demonstrate how cross-lagged effects can be used to assess the risk ratio of different levels of psychosocial safety climate (PSC) in organisations, an important psychosocial risk for the development of dep…

medicine.medical_specialtyActuarial science05 social sciencesGold standard050401 social sciences methodscontinuous time modellingSafety climate0504 sociologycross-lagged effectsRelative riskCross laggedEnvironmental healthdepression0502 economics and businessEpidemiologymedicineincidence ratespsychosocial safety climatePsychologyRisk assessmentPsychosocialMonte Carlo simulation050203 business & managementApplied PsychologyDepression (differential diagnoses)Work & Stress
researchProduct

Technical note: Dosimetric study of a new Co-60 source used in brachytherapy

2007

The purpose of this study is to obtain the dosimetric parameters of a new Co-60 source used in high dose rate brachytherapy and manufactured by BEBIG (Eckert & Ziegler BEBIG GmbH, Germany). The Monte Carlo method has been used to obtain the dose rate distribution in the updated TG-43U1 formalism of the American Association of Physicists in Medicine. In addition, to aid the quality control process on treatment planning systems (TPS), a two-dimensional rectangular dose rate table, coherent with the TG-43U1 dose calculation formalism, is given. These dosimetric data sets can be used as input data of the TPS calculations and to validate them.

medicine.medical_specialtyComputer scienceNuclear engineeringmedicine.medical_treatmentMonte Carlo methodBrachytherapyImage registrationGeneral MedicineHigh-Dose Rate BrachytherapyMedical imagingmedicineDosimetryMedical physicsDose rateRadiation treatment planningMedical Physics
researchProduct

SU-FF-T-41: Monte Carlo Dosimetric Study of the New BEBIG Co-60 HDR Source

2005

Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Plannin…

medicine.medical_specialtyComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineDose distributionHigh-Dose Rate BrachytherapyMonte carlo codemedicineDosimetryMedical physicsDose rateAlgorithmMedical Physics
researchProduct

Monte Carlo study of the dose rate distributions for the Ir2.A85-2 and Ir2.A85-1 Ir-192 afterloading sources

2008

The two most commonly used modalities of cancer treatment in clinical brachytherapy practice today are high dose rate (HDR) and pulsed dose rate (PDR) brachytherapy. In a clinical treatment, quality dose rate distribution data sets of the brachytherapy sources are required for each source model. The purpose of this study is to obtain detailed dose rate distributions around the new BEBIG HDR and PDR Ir-192 brachytherapy sources. These distributions will then be used as input data in the treatment planning systems dedicated to brachytherapy and its calculations can be verified. The Monte Carlo method was used to obtain the dose rate distributions around the sources studied, taking into accoun…

medicine.medical_specialtyComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapyPulsed dose rateCancerGeneral Medicinemedicine.diseaseCancer treatmentmedicineDosimetryMedical physicsDose rateRadiation treatment planningMedical Physics
researchProduct

SU-FF-T-13: Monte Carlo Calculation of the TG-43 Dosimetric Parameters of a New BEBIG Ir-192 HDR Source

2005

Purpose: High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of available dosimetric data for all HDR Ir-192 sources is given, pointing out the lack of data for one of the sources, the used by the BEBIG MultiSource afterloading system (BEBIG GmbH, Germany). The purpose of this study is to obtain detailed dose rate distributions in liquid water media around this source. Material and …

medicine.medical_specialtyDose calculationComputer sciencemedicine.medical_treatmentBrachytherapyMonte Carlo methodmedicineDosimetryMedical physicsGeneral MedicineDose rateClinical treatmentAlgorithmMedical Physics
researchProduct

SU-FF-T-329: Monte Carlo Dosimetric Study of the Flexisource Ir-192 HDR Source

2006

Purpose:Brachytherapy with high dose rate (HDR) sources of 192 Ir is a usual practice in clinical brachytherapy today. The TG43 U1 update report recommends that accurate dose distribution data of the brachytherapysource in use should be obtained experimentally or by Monte Carlo (MC), to be used as input in the HDR Treatment Planning System (TPS). The purpose of this study is to obtain the dose rate distribution in liquid water media for the Flexisource HDR 192 Ir source (Isodose Control GmbH, Germany) using the Monte Carlo method to obtain the TG43 U1 parameters and the 2‐D rectangular dose rate table. Material and methods: The MC code GEANT4 (7.1 version) was used to estimate dose rate in …

medicine.medical_specialtyDose calculationComputer sciencemedicine.medical_treatmentMonte Carlo methodBrachytherapymedicineDosimetryMedical physicsGeneral MedicineDose rateRadiation treatment planningAlgorithmMedical Physics
researchProduct

Radiation transmission data for radionuclides and materials relevant to brachytherapy facility shielding

2008

To address the limited availability of radiation shielding data for brachytherapy as well as some disparity in existing data, Monte Carlo simulation was used to generate radiation transmission data for 60Co, 137CS, 198Au, 192Ir 169Yb, 170Tm, 131Cs, 125I, and 103pd photons through concrete, stainless steel, lead, as well as lead glass and baryte concrete. Results accounting for the oblique incidence of radiation to the barrier, spectral variation with barrier thickness, and broad beam conditions in a realistic geometry are compared to corresponding data in the literature in terms of the half value layer (HVL) and tenth value layer (TVL) indices. It is also shown that radiation shielding calc…

medicine.medical_specialtyMaterials sciencePhotonbusiness.industrymedicine.medical_treatmentMonte Carlo methodBrachytherapyGeneral MedicineRadiationComputational physicsElectromagnetic shieldingmedicineMedical physicsRadiation protectionbusinessHalf-value layerBeam (structure)Medical Physics
researchProduct