Search results for " Computed Tomography"
showing 10 items of 411 documents
ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA
2009
This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…
Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multi…
2020
Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-rel…
Intraosseous Fixation Compared to Plantar Plate Fixation for First Metatarsocuneiform Arthrodesis
2014
Background: Metatarsocuneiform (MTC) fusion is a treatment option for management of hallux valgus. We compared the biomechanical characteristics of an internal fixation device with plantar plate fixation. Methods: Seven matched pairs of feet from human cadavers were used to compare the intramedullary (IM) device plus compression screw to plantar plate combined with a compression screw. Specimen constructs were loaded in a cyclic 4-point bending test. We obtained initial/final stiffness, maximum load, and number of cycles to failure. Bone mineral density was measured with peripheral quantitative computed tomography. Performance was compared using time to event analysis with number of cycles …
Incidence of new foci of hepatocellular carcinoma after radiofrequency ablation: role of multidetector CT
2012
Purpose. The authors sought to assess the incidence of new foci of hepatocellular carcinoma (HCC) using multidetector computed tomography (MDCT) in patients treated with radiofrequency ablation (RFA). Materials and methods. Two readers retrospectively reviewed by consensus the follow-up MDCT studies of 125 patients (88 men and 37 women; mean age 68 years) with 141 HCCs (size 1–5.2 cm; mean 2.2 cm) treated with RFA. MDCT follow-up was performed at 1 and 3 months and every 6–12 months thereafter. Reviewers assessed: (1) the presence of new HCC foci in the same liver segment or in a different segment; (2) complete or incomplete tumor ablation; (3) tumour progression. Results. A total of 113 ne…
Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement
2013
Background— Aortic root rupture is a major concern with balloon-expandable transcatheter aortic valve replacement (TAVR). We sought to identify predictors of aortic root rupture during balloon-expandable TAVR by using multidetector computed tomography. Methods and Results— Thirty-one consecutive patients who experienced left ventricular outflow tract (LVOT)/annular/aortic contained/noncontained rupture during TAVR were collected from 16 centers. A caliper-matched sample of 31 consecutive patients without annular rupture, who underwent pre-TAVR multidetector computed tomography served as a control group. Multidetector computed tomography assessment included short- and long-axis diameters an…
Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (C…
2017
The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute an…
Evaluation of ultrasound transmission velocity and 3-dimensional radiology in different bone types for dental implantology: a comparative ex vivo stu…
2013
Objective To evaluate ultrasound transmission velocity (UTV) for assessment of mechanical bone quality, an ex vivo comparison of different bone types measured with UTV, 2-dimensional (2D) histomorphometry and with 3-dimensional (3D) radiology (cone-beam computerized tomography [CBCT], computerized microtomography [μCT]) was conducted. Study Design Clinical cortical, cancellous, and mixed bone (each n = 6) was measured via UTV (m/s), CBCT (white pixel/black pixel ratio [WP/BP]), μCT (bone volume/total volume [μBV/TV]), and histomorphometry (bone volume/total volume [hBV/TV]). UTV values were correlated with 2D-histomorphometry and 3D-radiologic results. Results For the cortical, cancellous, …
Carotid intima media thickness and coronary atherosclerosis linkage in symptomatic intermediate risk patients evaluated by coronary computed tomograp…
2014
Background: There is a growing evidence that carotid intima media thickness (CIMT) is associated with coronary artery disease (CAD) and it should be used as a predictor of atherosclerotic burden of coronary arteries. However, these studies have been performed by using invasive coronary angiography (ICA) and in high-risk patients for CAD. The purpose of this study was to evaluate the correlation between CIMT by ultrasound and coronary atherosclerosis in symptomatic intermediate risk patients by coronary computed tomography angiography (CCTA). Methods: We enrolled 204 consecutive symptomatic patients (mean age: 61 +/- 10; men: 118) and intermediate risk for CAD. All patients underwent CIMT ul…
Functional Evaluation of Emphysema Using Diffusion-Weighted 3Helium-Magnetic Resonance Imaging, High-Resolution Computed Tomography, and Lung Functio…
2004
Purpose: To assess the emphysematous enlargement of distal air-spaces and concomitant large and small airway disease using diffusion-weighted 3 Helium-magnetic resonance imaging (MRI), high-resolution computed tomography (HRCT), and lung function tests (LFT). Methods: Seven patients were examined after single lung transplantation (LTx) and 1 before double LTx for various forms of emphysema. Five patients after double LTx served as controls. Patients were assessed by 3 Helium-MRI (apparent diffusion coefficient [ADC]), HRCT (mean lung density [MLD], emphysema index [El]), and LFT. Results: Transplanted lungs: mean ADC = 0.17 cm 2 /s, MLD = -848 H, El = 22%. Emphysematous lungs: mean ADC = 0.…
Bone rigidity to neuromuscular performance ratio in young and elderly men.
2009
Given the adaptation of bone to prevalent loading, bone loss should follow, but lag behind, the decline in physical performance during aging. Furthermore, bone responsiveness to load-induced strains is believed to decrease with aging. However, the relationship between bone and lean body ( approximately muscle) mass appears to remain rather constant throughout adulthood. The purpose of this study was to examine the association between age and bone to neuromuscular performance ratio. Young (N=20, age 24 SD+/-2 years, body mass 77+/-11 kg, height 178+/-6 cm) and elderly (N=25, 72+/-4 years, 75+/-9 kg, 172+/-5 cm) men served as subjects. Bone structural traits were measured at the right distal …