6533b859fe1ef96bd12b77b4

RESEARCH PRODUCT

Computed Tomography-Aortography Versus Color-Duplex Ultrasound for Surveillance of Endovascular Abdominal Aortic Aneurysm Repair: A Prospective Multicenter Diagnostic-Accuracy Study (the ESSEA Trial).

Elixène Jean-baptistePatrick FeugierCoralie CruzelGabrielle Sarlon-bartoliThierry ReixEric SteinmetzXavier ChaufourBertrand ChaventLucie Salomon Du MontMeghann EjargueBlandine MaurelRafaelle SpearDominique MidyFabien ThaveauPascal DesgrangesEugenio RossetRéda Hassen-khodjaPascale BureauMireille RavouxCatherine BozzettoMarie-antoinette Sevestre-pietriBéatrice TerriatClaire FavierMaryse DegeilhClaire Le HelloJean-pierre FavreSimon RinckenbachAnca LoppinetYann GouefficJérôme ConnaultYves AlimiPierre BarthélémyJean-luc MagneChristophe SeinturierMarie-luce ChoukrounOlivier RouyerLiliane BittonJean-pierre Becquemin

subject

Malemedicine.medical_specialtyAortographyTime FactorsComputed Tomography Angiographymedicine.medical_treatmentComputed tomographyDiagnostic accuracy030204 cardiovascular system & hematology030230 surgeryLikelihood ratios in diagnostic testingEndovascular aneurysm repairAortography03 medical and health sciencesBlood Vessel Prosthesis Implantation0302 clinical medicinePostoperative ComplicationsPredictive Value of TestsColor duplex ultrasoundMultidetector Computed TomographymedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesUltrasonography Doppler ColorProspective cohort studyAgedAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresReproducibility of Resultsmedicine.diseaseAbdominal aortic aneurysmTreatment OutcomeRetreatmentFemaleRadiologyFranceCardiology and Cardiovascular MedicinebusinessAortic Aneurysm Abdominal

description

Background Color-duplex ultrasonography (DUS) could be an alternative to computed tomography-aortography (CTA) in the lifelong surveillance of patients after endovascular aneurysm repair (EVAR), but there is currently no level 1 evidence. The aim of this study was to assess the diagnostic accuracy of DUS as an alternative to CTA for the follow-up of post-EVAR patients. Methods Between December 16, 2010, and June 12, 2015, we conducted a prospective, blinded, diagnostic-accuracy study, in 15 French university hospitals where EVAR was commonly performed. Participants were followed up using both DUS and CTA in a mutually blinded setup until the end of the study or until any major aneurysm-related morphological abnormality requiring reintervention or an amendment to the follow-up policy was revealed by CTA. Database was locked on October 2, 2017. Our main outcome measures were sensitivity, specificity, positive predictive value, negative predictive value, positive and negative likelihood ratios of DUS against reference standard CTA. CIs are binomial 95% CI. Results This study recruited prospectively 659 post-EVAR patients of whom 539 (82%) were eligible for further analysis. Following the baseline inclusion visit, 940 additional follow-up visits were performed in the 539 patients. Major aneurysm-related morphological abnormalities were revealed by CTA in 103 patients (17.2/100 person-years [95% CI, 13.9–20.5]). DUS accurately identified 40 patients where a major aneurysm-related morphological abnormality was present (sensitivity, 39% [95% CI, 29–48]) and 403 of 436 patients with negative CTA (specificity, 92% [95% CI, 90–95]). The negative predictive value and positive predictive value of DUS were 92% (95% CI, 90–95) and 39% (95% CI, 27–50), respectively. The positive likelihood ratio was 4.87 (95% CI, 2.9–9.6). DUS sensitivity reached 73% (95% CI, 51–96) in patients requiring an effective reintervention. Conclusions DUS had an overall low sensitivity in the follow-up of patients after EVAR, but its performance improved meaningfully when the subset of patients requiring effective reinterventions was considered. Registration URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01230203.

10.1161/circimaging.119.009886https://pubmed.ncbi.nlm.nih.gov/32507021