Search results for "Aortography"
showing 10 items of 44 documents
Aortic dissection detected by transoesophageal echocardiography
1986
The diagnostic value of transoesophageal echocardiography was evaluated in 24 patients with aortic dissection and compared to transthoracic two-dimensional echocardiography, computer tomography, aortography, surgery and autopsy. Using transoesophageal echocardiography we found in 5 patients a type I dissection, in 5 patients a type II and in 14 patients a type III dissection. Transthoracic two-dimensional echocardiography was positive in 3/5 type I, 2/5 in type II and 2/14 in type III dissections. Computer tomography was unable to demonstrate an intimal flap in 1/2 patients with type I, 2/3 type II and 1/11 type III dissections. Aortography was negative in 1/4 type I, 3/5 type II and 3/12 p…
Multiple periscope and chimney grafts to treat ruptured thoracoabdominal and pararenal aortic aneurysms
2011
Purpose: To report midterm outcomes after urgent endovascular repair of ruptured pararenal or thoracoabdominal aortic aneurysms using multiple periscope and chimney grafts to preserve renovisceral branch perfusion and facilitate aneurysm exclusion. Methods: Nine consecutive men (mean age 72614 years, range 40–88) presenting with ruptured thoracoabdominal (n56), pararenal (n52), or infrarenal (n51) aortic aneurysm underwent urgent endovascular repair with at least 1 periscope graft delivered via a transfemoral access; chimney grafts were installed from an axillary access. In all, 17 periscope and 7 chimney grafts were used to reperfuse 11 renal and 13 visceral arteries in the 9 patients. The…
Echocardiography in diagnosis of aortic dissection.
1989
In a multicentre study the accuracy of echocardiography was measured in 164 consecutive patients with suspected aortic dissection. The diagnosis was subsequently proven (82 patients) on the basis of transthoracic and transoesophageal echocardiography and additional diagnostic procedures, including computed tomography (CT), aortic angiography, and surgery and/or necropsy. The sensitivity and specificity of echocardiography were 99% and 98%, respectively, with positive and negative predictive values of 98% and 99%. For CT sensitivity was 83%, specificity 100%, and positive and negative predictive values 100% and 86%, respectively. For aortography sensitivity and specificity were 88% and 94%, …
Chimney and periscope grafts to facilitate endovascular treatment of aortic transection in a patient with aberrant right subclavian artery
2014
Purpose: To report the use of parallel grafts to extend the proximal landing zone for stentgraft repair of aortic transection involving an aberrant right subclavian artery (ARSA). Case Report: A 28-year-old patient was referred for treatment of traumatic aortic transection with contained rupture at the level of an ARSA. Immediate thoracic endovascular aortic repair (TEVAR) was planned because of hemodynamic instability. To achieve rapid sealing and maintain perfusion to both subclavian arteries, a chimney stent to the left subclavian artery (LSA) and a periscope stent-graft to the ARSA were deployed successfully. After surgical repair of all fractures, the patient was discharged 1 month aft…
Computer Modeling for the Prediction of Thoracic Aortic Stent Graft Collapse
2011
OBJECTIVE: To assess the biomechanical implications of excessive stent protrusion into the aortic arch in relation to thoracic aortic stent graft (TASG) collapse by simulating the structural load and quantifying the fluid dynamics on the TASG wall protrusion extended into a model arch. METHODS: One-way coupled fluid-solid interaction analyses were performed to investigate the flow-induced hemodynamic and structural loads exerted on the proximal protrusion of the TASG and aortic wall reconstructed from a patient who underwent traumatic thoracic aortic injury repair. Mechanical properties of a Gore TAG thoracic endoprosthesis (W. L. Gore and Assoc, Flagstaff, Ariz) were assessed via experimen…
An In Vitro Phantom Study on the Role of the Bird-Beak Configuration in Endograft Infolding in the Aortic Arch.
2015
Purpose: To assess endograft infolding for excessive bird-beak configurations in the aortic arch in relation to hemodynamic variables by quantifying device displacement and rotation of oversized stent-grafts deployed in a phantom model. Methods: A patient-specific, compliant, phantom pulsatile flow model was reconstructed from a patient who presented with collapse of a Gore TAG thoracic endoprosthesis. Device infolding was measured under different flow and pressure conditions for 3 protrusion extensions (13, 19, and 24 mm) of the bird-beak configuration resulting from 2 TAG endografts with oversizing of 11% and 45%, respectively. Results: The bird-beak configuration with the greatest protr…
Acute aortic dissection debut as STEMI: A case report
2014
Abstract We submit a case report of a 66-year-old male, with hypertension and family history of cerebrovascular disease, who was referred to our department for right-inferior STEMI. According to the current ESC (European Society of Cardiology) guidelines for the management of STEMI, the patient was conducted to the cath lab to perform primary PCI. Despite the identification of the culprit lesion we had many difficulties during the procedure of angioplasty, so we decided to perform aortography that showed a Stanford type A acute aortic dissection involving the ostium of right coronary artery causing the right-inferior STEMI. In the early phase of a STEMI, exclusion of the presence of aortic …
In Silico Shear and Intramural Stresses are Linked to Aortic Valve Morphology in Dilated Ascending Aorta
2017
Objective/Background: The development of ascending aortic dilatation in patients with bicuspid aortic valve (BAV) is highly variable, and this makes surgical decision strategies particularly challenging. The purpose of this study was to identify new predictors, other than the well established aortic size, that may help to stratify the risk of aortic dilatation in BAV patients.Methods: Using fluid-structure interaction analysis, both haemodynamic and structural parameters exerted on the ascending aortic wall of patients with either BAV ( n = 21) or tricuspid aortic valve (TAV; n = 13) with comparable age and aortic diameter (42.7 +/- 5.3 mm for BAV and 45.4 +/- 10.0 mm for TAV) were compared…
Mortality of ruptured abdominal aortic aneurysm with selective use of endovascular repair
2009
The aim of this review was to examine the results over a seven-year period of treatment for ruptured abdominal aortic aneurysm (RAAA). From 2002 on, our tertiary referral centre offered both open and endovascular (EVAR) treatment modalities for RAAA. All patients with a proven RAAA who were admitted into our hospital were included. Primary outcome measure was surgical mortality. In total 261 patients were admitted with suspicion of acute AAA. Of these, 175 (67%) had a RAAA, confirmed by computed tomography-scanning or at laparotomy. One hundred and fifty-nine patients (90.9%) were treated, 114 by open repair and 45 by EVAR. Overall mortality of patients treated was 25.2%, with an open repai…
A New Off-Pump Hybrid Open and Endovascular Repair to Treat Ductus Botalli and Ascendens Aneurysms
2012
To report a combined ascending aorta and aortic arch hybrid repair, we performed off-pump with no aortic graft replacement. A 65-year-old man, developing progressive recurrent laryngeal nerve paralysis, underwent a computed tomography (CT) angiography detecting nonpatent residual ductus Botalli aneurysm and ascending aorta aneurysm. Due to severe multimorbidities, a less-invasive alternative was elaborated. In a first step, appropriate proximal landing zone for aortic stent grafting was achieved by ascending aorta diameter reduction, with epiaortic wrapping, and debranching the supra-aortic trunks. In the second step, endovascular stent grafts were deployed from proximal ascending aorta to…