Search results for " Computer-Assisted"

showing 10 items of 1033 documents

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Reference Ranges and Distribution of Placental Volume by 3-Dimensional Virtual Organ Computer-Aided Analysis Between 11 Weeks and 13 Weeks 6 Days

2013

OBJECTIVES The purpose of this study was to determine the feasibility, reproducibility, and distribution of placental volume measurements according to the crown-rump length between 11 weeks and 13 weeks 6 days. METHODS Images were acquired in 128 pregnancies followed in Burgundy during first-trimester screening sonography using an abdominal 3-dimensional transducer. The placental volume was then calculated by the virtual organ computer-aided analysis method with a rotation angle of 30° by a single operator. RESULTS Placental volumes ranged from 33.3 to 107.6 cm(3) with a mean ± SD of 62.3 ± 14.8 cm(3); the 5th and 10th percentiles were 38.0 and 44.20 cm(3), respectively, whereas the 90th an…

AdultPercentileAdolescentSensitivity and SpecificityCrown-Rump LengthUltrasonography PrenatalMean differenceYoung AdultImaging Three-DimensionalPregnancyReference ValuesImage Interpretation Computer-AssistedPlacental volumeHumansMass ScreeningMedicineRadiology Nuclear Medicine and imagingMass screeningCrown-rump lengthReproducibilityRadiological and Ultrasound Technologybusiness.industryReproducibility of ResultsOrgan SizeOrgan SizePregnancy Trimester FirstFemaleFrancebusinessNuclear medicineIntraobserver reproducibilityJournal of Ultrasound in Medicine
researchProduct

Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…

2010

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…

AdultPulse repetition frequencyLinguistics and Languagemedicine.medical_specialtySpeech perceptionAdolescentHearing Loss SensorineuralLoudness Perceptionmedicine.medical_treatmentmedia_common.quotation_subjectAudiologyProsthesis DesignAffect (psychology)Severity of Illness IndexLanguage and LinguisticsCochlear nucleusLoudnessYoung AdultSpeech and HearingProsthesis FittingCochlear implantPerceptionmedicineHumansCorrection of Hearing ImpairmentHabituationAgedmedia_commonAged 80 and overAuditory ThresholdSignal Processing Computer-AssistedMiddle AgedElectric StimulationEuropeCochlear ImplantsPersons With Hearing ImpairmentsAcoustic StimulationAuditory PerceptionSpeech PerceptionAudiometry SpeechPsychologyInternational Journal of Audiology
researchProduct

Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic

1999

Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…

Adultmedicine.diagnostic_testVentricular functionComputer scienceDynamic dataMyocardial InfarctionMagnetic Resonance Imaging CineStroke VolumeMagnetic resonance imagingGeneral MedicineMiddle AgedFuzzy logicManual extractionFuzzy LogicImage Processing Computer-Assistedcardiovascular systemmedicineHumansVentricular FunctionRadiology Nuclear Medicine and imagingcardiovascular diseasesWall thicknessAgedBiomedical engineeringInvestigative Radiology
researchProduct

Automatic determination of aortic compliance with cine-magnetic resonance imaging - An application of fuzzy logic theory

2002

International audience; Abstract: RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level o…

Adultmedicine.medical_specialtyAdolescentComputer scienceMagnetic Resonance Imaging CineImage processingFuzzy logicMarfan Syndromecine-MRImedicineImage Processing Computer-Assisted[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansautomatic contour detectionRadiology Nuclear Medicine and imagingChildAortamedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical Imagingbusiness.industryResonanceMagnetic resonance imagingGeneral MedicineMiddle AgedCine mriSurgeryCompliance (physiology)Case-Control Studiescardiovascular systemfuzzy logicNuclear medicinebusinessaortic compliance
researchProduct

The internal calcar septum and its contact with the virtual stem in THR: a computer tomographic evaluation.

2003

The internal calcar septum is a ridge of cortical bone protruding from the inner cortical wall of the proximal femur into the medullary canal. It extends from the lesser trochanter into the femoral neck and narrows the femoral cavity in its dorsal third. This region is essential for THR stability, but the degree of contact between the septum and standard THR implants has never been studied. We obtained CT scans of 50 arthrotic hip joints from patients requiring THR. Virtual stems (50 straight/wedge-shaped and 50 anatomic stems) were placed in CT images of the femora using a PC-based preoperative planning unit. The dimensions of the septum, degree and location of contact between the septum a…

Adultmedicine.medical_specialtyCalcarMedullary cavitybusiness.industryArthroplasty Replacement HipAnatomyRoboticsMiddle Agedmedicine.anatomical_structureLesser TrochanterOrthopedic surgerymedicineImage Processing Computer-AssistedHumansOrthopedics and Sports MedicineSurgeryCortical boneFemurImplantFemurHip ProsthesisbusinessTomography X-Ray ComputedFemoral neckActa orthopaedica Scandinavica
researchProduct

Hepatic Hilar and Sectorial Vascular and Biliary Anatomy in Right Graft Adult Live Liver Donor Transplantation

2008

Abstract Introduction The aim of this study was to analyze vascular and biliary variants at the hilar and sectorial level in right graft adult living donor liver transplantation. Methods From January 2003 to June 2007, 139 consecutive live liver donors underwent three-dimensional computed tomography (3-D CT) reconstructions and virtual 3-D liver partitioning. We evaluated the portal (PV), arterial (HA), and biliary (BD) anatomy. Results The hilar and sectorial biliary/vascular anatomy was predominantly normal (70%–85% and 67%–78%, respectively). BD and HA showed an equal incidence (30%) of hilar anomalies. BD and PV had a nearly identical incidence of sectorial abnormalities (64.7% and 66.2…

Adultmedicine.medical_specialtyCholecystographymedicine.medical_treatmentHilum (biology)Hepatic VeinsLiver transplantationliverHepatic ArteryImage Processing Computer-AssistedLiving DonorsmedicineHumansPorta hepatisTransplantationmedicine.diagnostic_testbusiness.industryGallbladderCholecystographyLiver TransplantationSurgeryTransplantationmedicine.anatomical_structureBiliary tractCirculatory systemSurgeryHepatectomyTomography X-Ray ComputedNuclear medicinebusinessTransplantation Proceedings
researchProduct

Macular edema computer-aided evaluation in ocular vein occlusions.

1998

This paper is concerned with the use of digital fundus imaging to detect, quantify, and follow up macular angiographic leakage due to retinal vein occlusions. Images were matched automatically. We detected those pixels with a high increment in gray level within the closest area to the foveal center. Binary images displaying leakage were obtained. The procedure was checked against two observers' agreement. Twenty-one angiographic studies were collected. Two images of each sequence were selected for digitalization. Numerical descriptors of the leakage were proposed and quantification plots were designed for each pair of images. Interobserver concordance ranged between 82 and 98% when manually…

Adultmedicine.medical_specialtyComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONMedicine (miscellaneous)Capillary PermeabilityFovealOcclusionRetinal Vein OcclusionmedicineEdemaHumansMacula LuteaDiagnosis Computer-AssistedFluorescein AngiographyMacular edemaObserver VariationPixelmedicine.diagnostic_testbusiness.industryBinary imagemedicine.diseaseFluorescein angiographyPrognosisEvaluation Studies as TopicMaculopathyFemaleRadiologybusinessRetinopathyComputers and biomedical research, an international journal
researchProduct

OCT for Assessing Artificial Tears Effectiveness in Contact Lens Wearers

2011

PURPOSE: To apply a commercially available high-resolution spectral domain optical coherence tomographer (SOCT) to assess the change in tear volume after application of a new artificial tears formulation specifically developed for contact lens (CL) users. METHODS: Twenty OD from young healthy CL wearers (mean age, 24.7 ± 3.5 years) with refractive errors ranging from -0.75 to -2.50 D (mean, -1.56 ± 0.69 D) were examined. All subjects were fitted with Focus Dailies CL (Ciba Vision), and two drops of Blink Contacts (AMO), lubricating formulation specifically developed for CL wearers, were instilled after baseline measures. Tear meniscus volume (TMV) was measured immediately after and 1 min, 1…

Adultmedicine.medical_specialtyContact Lensesmedicine.medical_treatmentMeniscus (anatomy)Tear volumeYoung AdultRegular distributionOphthalmologyImage Processing Computer-AssistedHumansMedicinebusiness.industryRepeated measures designContact Lenses HydrophilicRefractive ErrorsContact lensOphthalmologyArtificial tearsmedicine.anatomical_structureTear meniscusOftalmologíaDry Eye SyndromesEyelidOphthalmic SolutionsbusinessTomography Optical CoherenceFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

The accuracy and reproducibility of the endometrial receptivity array is superior to histology as a diagnostic method for endometrial receptivity

2013

Objective To compare the accuracy and reproducibility of the endometrial receptivity array (ERA) versus standard histologic methods. Design A comparative prospective study (May 2008–May 2012). Setting University-affiliated infertility clinic. Patient(s) Eighty-six healthy oocyte donors, regularly cycling, aged 20–34 years with a body mass index (BMI) of 19–25 kg/m 2 . Intervention(s) Endometrial biopsies were collected throughout the menstrual cycle. For the accuracy study, 79 samples were grouped into two cohorts: the training set (n = 79) for ERA machine-learning training and dating, and a dating subset (n = 49) for comparison between histologic and ERA dating. For the reproducibility stu…

Adultmedicine.medical_specialtyDiagnostic methodsBiopsyConcordancemedia_common.quotation_subjectSensitivity and SpecificityEndometriumYoung AdultArtificial IntelligencemedicineHumansDiagnosis Computer-AssistedProspective cohort studyMenstrual cyclemedia_commonGynecologyOvulation DetectionReproducibilitybusiness.industryReproducibility of ResultsObstetrics and GynecologyHistologyReproductive MedicineFemaleEndometrial receptivitybusinessBody mass indexBiomarkersFertility and Sterility
researchProduct