Search results for " Computer-Assisted"

showing 10 items of 1033 documents

Effectiveness of a transdiagnostic internet-based protocol for the treatment of emotional disorders versus treatment as usual in specialized care: st…

2015

Emotional disorders (depression and anxiety disorders) are highly prevalent mental health problems. Although evidence showing the effectiveness of disorder-specific treatments exists, high comorbidity rates among emotional disorders limit the utility of these protocols. This has led some researchers to focus their interest on transdiagnostic interventions, a treatment perspective that might be more widely effective across these disorders. Also, the current way of delivering treatments makes it difficult provide assistance to all of the population in need. The use of the Internet in the delivery of evidence-based treatments may help to disseminate treatments among the population. In this stu…

Malemedicine.medical_specialtyGeneralized anxiety disorderTime FactorsEmotionsPsychological interventionMedicine (miscellaneous)AnxietyStudy ProtocolClinical ProtocolsSurveys and QuestionnairesmedicineHumansPharmacology (medical)PsychiatryComputer-delivered psychotherapyPsychiatric Status Rating ScalesTransdiagnosticExtraversion/behavioral activationDepressive DisorderInternetbusiness.industryDepressionPanic disorderSocial anxietyEmotional disordersmedicine.diseaseNeuroticism/behavioral inhibitionNeuroticismAnxiety DisordersIntention to Treat AnalysisPsychotherapyTreatment OutcomePatient SatisfactionResearch DesignSpainRandomized controlled trialTherapy Computer-AssistedQuality of LifeAnxietyFemalemedicine.symptombusinessDelivery of Health CareAnxiety disorderAgoraphobiaClinical psychologyTrials
researchProduct

Imaging processing for CT angiography of the cervicocranial arteries: evaluation of reformatting technique.

2007

Purpose. The aim of this study was to compare computed tomography angiography (CTA) sliding-thin-slab (STS) multiplanar reformatting (MPR), STS maximum intensity projection (MIP) and three-dimensional (3D) volume rendering (VR) reformatting techniques in the evaluation of cervicocranial arteries. Materials and methods. Twenty patients examined with multislice CT were included in this study. CTA images were reformatted as STS-MIP, STS-MPR and 3DVR in orthogonal planes and in the oblique-coronal plane. Images were evaluated in consensus by two radiologists, with a third radiologist to resolve discordances in grading image quality parameters. The Spearman correlation analysis was performed to …

Malemedicine.medical_specialtyImage qualityCT CT angiography Cervicocranial arterieImaging Three-DimensionalmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingVertebral ArteryComputed tomography angiographyNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundAngiographyBrainVolume renderingGeneral MedicineCerebral ArteriesMiddle AgedCerebral AngiographyCerebrovascular DisordersCarotid ArteriesMaximum intensity projectionAngiographyCervical VertebraeFemaleRadiologyImaging processingNuclear medicinebusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct

Reproducible coronary plaque quantification by multislice computed tomography

2007

BACKGROUND: The aim of this study was to investigate reproducibility and accuracy of computer-assisted coronary plaque measurements by multislice computed tomography coronary angiography (QMSCT-CA). METHODS AND RESULTS: Forty-eight patients undergoing MSCT-CA and coronary arteriography for symptomatic coronary artery disease and quantitative intravascular ultrasound (IVUS, QCU) were examined. Two investigators performed the QMSCT-CA twice and a third investigator performed the QCU, all blinded for each other's results. There was no difference found for the matched region of interest (ROI) lengths (QCU 29.4 +/- 13 mm vs. QMSCT-CA 29.6 +/- 13 mm, P = 0.6; total length = 1,400 mm). The compari…

Malemedicine.medical_specialtyLumen (anatomy)Coronary Angiographymultislice computed tomographyintravascular ultrasoundCoronary artery diseasePredictive Value of TestsRegion of interestCoronary plaqueImage Interpretation Computer-AssistedIntravascular ultrasoundmedicineHumansRadiology Nuclear Medicine and imagingUltrasonography InterventionalAgedObserver VariationReproducibilitymedicine.diagnostic_testbusiness.industryReproducibility of ResultsGeneral MedicineMultislice computed tomographyMiddle Agedmedicine.diseaseimage processingResearch DesignPredictive value of testsFemaleRadiologyTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E RadioterapiaCardiology and Cardiovascular Medicinebusinesscoronary artery diseaseCatheterization and Cardiovascular Interventions
researchProduct

Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary…

2007

Attenuation variability ( measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/infinity) and a 1/50 solution of contrast material ( 400 mgI/ml iomeprol). Scan parameters were: slices/ collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques …

Malemedicine.medical_specialtyMultislice computed tomographyConvolutions KernelsCoronary angiographyIomeprolMyocardial IschemiaContrast MediaCoronary Artery DiseaseIn Vitro TechniquesCoronary AngiographySensitivity and SpecificityIopamidolCoronary artery diseasechemistry.chemical_compoundHounsfield scaleMedicine and Health SciencesmedicineImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingAgedConvolutions kernelsCoronary Plaquebusiness.industryAttenuationUltrasoundMultislice computed tomography Coronary angiography Coronary plaque Convolutions kernelsModels CardiovascularGeneral MedicineMiddle Agedmedicine.diseaseImage EnhancementIopamidolCoronary arteriesmedicine.anatomical_structurechemistryRadiology Nuclear Medicine and imagingFemaleRadiologybusinessNuclear medicineTomography Spiral ComputedCardiacCoronary plaqueEx vivoMultislice Computed Tomographymedicine.drug
researchProduct

Focal cortical damage parallels cognitive impairment in minimal hepatic encephalopathy

2012

Little attention has been paid to cortical integrity in patients with minimal hepatic encephalopathy (MHE), although cognitive functions affected in early stages of liver disease are mainly allocated in different neocortical structures. Here we used cortical surface-based analysis techniques to investigate if patterns of cortical thinning accompany the mildest form of HE. To aim this goal, cortical thickness obtained from high-resolution 31 magnetic resonance imaging (MRI) was measured in patients with no MHE (NMHE), MHE, and healthy controls. Further correlation analyses were performed to examine whether scores in the critical flicker frequency (CFF) test, and blood ammonia levels accounte…

Malemedicine.medical_specialtyPathologyCognitive NeuroscienceMinimal hepatic encephalopathyPrecuneusFlicker fusion thresholdNeuropsychological TestsCortical thicknessLiver diseaseInternal medicineImage Interpretation Computer-AssistedmedicineHumansHepatic encephalopathyTemporal cortexCerebral Cortexmedicine.diagnostic_testMagnetic resonance imagingCognitionMiddle Agedmedicine.diseaseEarly diagnosisMagnetic Resonance ImagingCalcarine sulcusmedicine.anatomical_structureEarly DiagnosisCognitive impairmentNeurologyHepatic cirrhosisHepatic EncephalopathyCardiologyFemalePsychologyCognition Disordershuman activities
researchProduct

Reducing Patient Radiation Dose With Image Noise Reduction Technology in Transcatheter Aortic Valve Procedures

2015

X-ray radiation exposure is of great concern for patients undergoing structural heart interventions. In addition, a larger group of medical staff is required and exposed to radiation compared with percutaneous coronary interventions. This study aimed at quantifying radiation dose reduction with implementation of specific image noise reduction technology (NRT) in transcatheter aortic valve implantation (TAVI) procedures. We retrospectively analyzed 104 consecutive patients with TAVI procedures, 52 patients before and 52 after optimization of x-ray radiation chain, and implementation of NRT. Patients with 1-step TAVI and complex coronary intervention, or complex TAVI procedures, were excluded…

Malemedicine.medical_specialtyPercutaneousImage quality030204 cardiovascular system & hematology030218 nuclear medicine & medical imagingTranscatheter Aortic Valve ReplacementIntraoperative Period03 medical and health sciencesKerma0302 clinical medicineGermanyInternal medicineMultidetector Computed TomographyImage noise reductionmedicineHumansFluoroscopyCardiac skeletonRadiation InjuriesRetrospective StudiesAged 80 and overmedicine.diagnostic_testbusiness.industryIncidenceDose-Response Relationship RadiationRetrospective cohort studyAortic Valve StenosisPrognosismedicine.diseaseSurgery Computer-AssistedFluoroscopyAortic valve stenosisCardiologyFemaleRadiologyCardiology and Cardiovascular MedicinebusinessFollow-Up StudiesThe American Journal of Cardiology
researchProduct

Value of magnetic-resonance cholangio-pancreatography (MRCP) after unsuccessful endoscopic-retrograde cholangio-pancreatography (ERCP).

1997

Background and Study Aims: The present study tries to evaluate the success rate of MRCP when two attempts by experts to perform ERCP in a center failed. Patients and Methods: From March 1996 to December 1996 thirteen patients fulfilled the inclusion criteria. The MR cholangiopancreatograms were acquired using commercially available software in a clinical MR scanner (Magnetom Expert 1T-Scanner, Siemens, Erlangen, Germany). MRCP utilized heavily T2-weighted turbo-spin echo sequences with fat supression (HASTE). Maximum intensity projection (MIP) of the pancreatic duct and biliary tree was then carried out. Additionally, T1-weighted sequences were obtained using the breath-hold technique. Resu…

Malemedicine.medical_specialtyPercutaneousPancreatic pseudocystBiliary Tract DiseasesmedicineImage Processing Computer-AssistedHumansMedical diagnosisAgedPancreatic ductAged 80 and overCholangiopancreatography Endoscopic Retrogrademedicine.diagnostic_testbusiness.industryBile ductGastroenterologyPancreatic DiseasesMagnetic resonance imagingMiddle Agedmedicine.diseaseMagnetic Resonance Imagingmedicine.anatomical_structureMaximum intensity projectionFemaleRadiologybusinessEndoscopic retrograde cholangio-pancreatographyEndoscopy
researchProduct

Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: preoperative classification accuracy and histopathologic corre…

2012

Abstract Background To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as cont…

Malemedicine.medical_specialtyPerfusion ImagingHemodynamicsSensitivity and Specificity030218 nuclear medicine & medical imagingCorrelation03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCortex (anatomy)Preoperative CaremedicineHumansRadiology Nuclear Medicine and imagingNeovascularization Pathologicbusiness.industryBrain NeoplasmsReproducibility of ResultsGeneral MedicineMiddle AgedPrognosisTumor BurdenCerebral blood volumemedicine.anatomical_structureMaximum intensity projectionBrain sizeCerebral hemisphereRadiographic Image Interpretation Computer-AssistedFemaleRadiologyNuclear medicinebusinessTomography X-Ray ComputedPerfusion030217 neurology & neurosurgeryAlgorithmsEuropean journal of radiology
researchProduct

Acoustics of snoring and automatic snore sound detection in children

2017

Objective Acoustic analyses of snoring sounds have been used to objectively assess snoring and applied in various clinical problems for adult patients. Such studies require highly automatized tools to analyze the sound recordings of the whole night's sleep, in order to extract clinically relevant snore- related statistics. The existing techniques and software used for adults are not efficiently applicable to snoring sounds in children, basically because of different acoustic signal properties. In this paper, we present a broad range of acoustic characteristics of snoring sounds in children (N = 38) in comparison to adult (N = 30) patients. Approach Acoustic characteristics of the signals we…

Malemedicine.medical_specialtyPhysiologySpeech recognitionAcousticsBiomedical EngineeringBiophysicsPolysomnographyAudiologyLoudnessAutomation03 medical and health sciences0302 clinical medicine030225 pediatricsPhysiology (medical)medicineHumansRespiratory soundsChildmedicine.diagnostic_testbusiness.industrymusculoskeletal neural and ocular physiologySnoringSound detectionSignal Processing Computer-AssistedAcousticsMiddle Agednervous system diseasesrespiratory tract diseasesSoundFormantSpectral envelopeFrequency domainpopulation characteristicsSpectrogramFemalebusinessAlgorithmspsychological phenomena and processes030217 neurology & neurosurgeryPhysiological Measurement
researchProduct

Role of the basolateral amygdala in retrieval of conditioned flavors in the awake rat.

2014

International audience; Learned association between odor, taste and further post-ingestive consequence is known as flavor nutrient conditioned preference. Amygdala is supposed to be one of the areas involved in these associations. In the present study, one flavor was associated with a 16% glucose (CS+) whereas another flavor was paired with less reinforcing 4% glucose (CS-). We showed that CS+ presentation after conditioning increased Fos expression in the basolateral nucleus of amygdala (BLA). Furthermore, we performed electrophysiological recordings in the BLA in free moving rats. After preference acquisition, rats were exposed to either the CS+ or the CS-. The proportion of neurons showi…

Malemedicine.medical_specialtyTasteAction PotentialsAmygdalaPreference03 medical and health sciencesBehavioral NeuroscienceEatingFood Preferences0302 clinical medicineInternal medicine[SDV.IDA]Life Sciences [q-bio]/Food engineeringConditioning PsychologicalmedicineAnimals[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process EngineeringRats WistarFlavor030304 developmental biologyNeurons0303 health sciencesBasolateral Nuclear Complexfood and beveragesTaste PerceptionSignal Processing Computer-AssistedAmygdalaFlavorImmunohistochemistryElectrodes ImplantedElectrophysiologyElectrophysiologymedicine.anatomical_structureEndocrinologyGlucoseOncogene Proteins v-fosOdorAwake ratConditioningPsychologyFood DeprivationNeuroscienceNucleus030217 neurology & neurosurgeryBasolateral amygdalaConditioningBehavioural brain research
researchProduct