Search results for " Computer-Assisted"
showing 10 items of 1033 documents
Filter performance parameters for vectorial high-aperture wave fields.
2008
Performance parameters have been presented that can be used to compare the focusing performance of different optical systems, including the effect of pupil filters. These were originally given for the paraxial case and recently extended to the high-aperture scalar regime. We generalize these parameters to the full vectorial case for an aplanatic optical system illuminated by a plane-polarized wave. The behavior of different optical systems is compared.
Irradiation facility at the TRIGA Mainz for treatment of liver metastases
2009
Abstract The TRIGA Mark II reactor at the University of Mainz provides ideal conditions for duplicating BNCT treatment as performed in Pavia, Italy, in 2001 and 2003 [Pinelli, T., Zonta, A., Altieri, S., Barni, S., Braghieri, A., Pedroni, P., Bruschi, P., Chiari, P., Ferrari, C., Fossati, F., Nano, R., Ngnitejeu Tata, S., Prati, U., Ricevuti, G., Roveda, L., Zonta, C., 2002. TAOrMINA: from the first idea to the application to the human liver. In: Sauerwein et al. (Eds.), Research and Development in Neutron Capture Therapy. Proceedings of the 10th International Congress on Neutron Capture Therapy, Monduzzi editore, Bologna, pp. 1065–1072]. In order to determine the optimal parameters for the…
Brachytherapy structural shielding calculations using Monte Carlo generated, monoenergetic data
2014
Purpose: To provide a method for calculating the transmission of any broad photon beam with a known energy spectrum in the range of 20–1090 keV, through concrete and lead, based on the superposition of corresponding monoenergetic data obtained from Monte Carlo simulation. Methods: MCNP5 was used to calculate broad photon beam transmission data through varying thickness of lead and concrete, for monoenergetic point sources of energy in the range pertinent to brachytherapy (20–1090 keV, in 10 keV intervals). The three parameter empirical model introduced byArcher et al. [“Diagnostic x-ray shielding design based on an empirical model of photon attenuation,” Health Phys. 44, 507–517 (1983)] was…
Comparison between transmission and scattering spectrum reconstruction methods based on EPID images.
2013
Numerous improved physics-based methods for Linac photon spectra reconstruction have been published; some of them are based on transmission data analysis and others on scattering data. In this work, the two spectrum unfolding approaches are compared in order to experimentally validate its robustness and to determine which is the optimal methodology for application on a clinical quality assurance routine. Both studied methods are based on EPID images generated when the incident photon beam impinges onto plastic blocks. The distribution of transmitted/scatter radiation produced by this object centered at the beam field size was measured. Measurements were performed using a 6 MeV photon beam p…
Monte Carlo calculation of dose rate distributions around the Walstam CDC.K-type137Cs sources
2001
Basic dosimetric data for the Walstam CDC.K-type low dose rate 137Cs sources in water have been calculated using Monte Carlo techniques. These sources, CDC.K1 -K3 and CDC.K4, are widely used in a range of applicators and moulds for the treatment of intracavitary and superficial cancers. Our purpose is to improve existing data about these sources using the Monte Carlo simulation code GEANT3. Absolute dose rate distributions in water have been calculated around these sources and are presented as conventional 2D Cartesian look-up tables. Also the AAPM Task Group 43 formalism for dose calculation has been applied. The calculated dose rate constant for the CDC.K1-K3 source is A = 1.106 +/- 0.001…
Dosimetric characteristics of backscattered electrons in lead.
2000
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) was defined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence…
Simulation of skin reflectance images using 3D tissue modeling and multispectral Monte Carlo light propagation.
2008
In this work we propose a method to simulate the expected, i.e. seen by a camera, multispectral reflectance images of a large skin surface area by combining Monte Carlo light propagation model and realistic tissue modeling based on three dimensional data acquisition of human body areas. In particular, we aim to simulate more accurately light transport in biological tissue by taking into account the geometrical topography of the skin surface, the structure and optical properties of the skin layers, and the subcutaneous veins in presence. We describe our computation method in detail and present simulated reflectance images results.
A Monte Carlo investigation of the dosimetric characteristics of the CSM11 137Cs source from CIS
2000
The purpose of this study is to calculate basic dosimetry data for a CSM11 low dose rate 137Cs source in water. This source is widely used in afterloadable dome cylinders designed to homogeneously irradiate the vaginal cuff alone or additional areas of the vagina in hysterectomized patients. In this study, the Monte Carlo simulation code GEANT, incorporating in detail source geometry, is used to investigate the dosimetric characteristics of the source. The calculated data were analyzed using a fitting procedure that is described in detail. Absolute dose rate distributions in water were calculated around this source and are presented as conventional 2D Cartesian lookup tables (classically al…
Dosimetric characteristics of the CDC-type miniature cylindrical 137Cs brachytherapy sources
2002
The low dose rate CDC-type miniature cylindrical 137 Cs sources are available, with one or three active beads, for use in source trains in automatic and manual afterloading systems for gynecological brachytherapy. Absolute dose rate distributions in water have been calculated around these sources using the Monte CarloGEANT3 code and they are presented as conventional two-dimensional Cartesian lookup tables. The AAPM Task Group 43 formalism for dose calculation has been also applied. The dose rate constant obtained for the one bead source is Λ=1.113±0.003 cGyh −1 U −1 , and the value for the three bead source is Λ=1.103±0.003 cGyh −1 U −1 . Finally, for the treatment planning systems based o…
Monte Carlo dosimetric characterization of the Cs-137 selectron/LDR source: evaluation of applicator attenuation and superposition approximation effe…
2004
The purpose of this study is to calculate the dose rate distribution for the Amersham Cs-137 pellet source used in brachytherapy with the Selectron low-dose-rate remote afterloading system in gynaecological applications using the Monte Carlo code GEANT4. The absolute dose rate distribution for the pellet source was obtained and presented as a one-dimensional absolute dose rate table as well as in the Task Group 43 dose-calculation formalism. In this study, excellent agreement was found between the point source theoretical model using fitted polynomial values and Monte Carlo calculations of the dose rate distribution for the pellet source. A comparison study was also made between the dose ra…