Search results for " Computer-Assisted"

showing 10 items of 1033 documents

The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.

2011

The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…

Radiation DosageComposite image filtersymbols.namesakeDigital imageOptical transfer functionMedian filterImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingGeneral DentistryMathematicsPixelPhantoms ImagingResearchGeneral MedicineRadiography Dental DigitalGaussian filterRadiographic Image EnhancementOtorhinolaryngologyGaussian noisesymbolsLinear ModelsArtifactsAlgorithmDigital filterAlgorithmsFiltrationDento maxillo facial radiology
researchProduct

Monte Carlo dosimetric study of the medium dose rate CSM40 source

2013

Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…

RadiationPhotonPhantoms Imagingbusiness.industryChemistryRadiotherapy Planning Computer-Assistedmedicine.medical_treatmentMonte Carlo methodBrachytherapyWaterRadiotherapy DosageImaging phantomComputational physicsKermaCesium RadioisotopesAbsorbed dosemedicineAnisotropyHumansRadiometryNuclear medicinebusinessRadiation treatment planningMonte Carlo MethodUncertainty analysisApplied Radiation and Isotopes
researchProduct

Determination of the irradiation field at the research reactor TRIGA Mainz for BNCT.

2009

For the application of the BNCT for the excorporal treatment of organs at the TRIGA Mainz, the basic characteristics of the radiation field in the thermal column as beam geometry, neutron and gamma ray energies, angular distributions, neutron flux, as well as absorbed gamma and neutron doses must be determined in a reproducible way. To determine the mixed irradiation field thermoluminescence detectors (TLD) made of CaF(2):Tm with a newly developed energy-compensation filter system and LiF:Mg,Ti materials with different (6)Li concentrations and different thicknesses as well as thin gold foils were used.

Radiation-Sensitizing AgentsMaterials scienceAstrophysics::High Energy Astrophysical PhenomenaPhysics::Medical PhysicsBoron Neutron Capture TherapyIn Vitro TechniquesThermoluminescenceTransplantation AutologousTRIGAFast NeutronsFluoridesIsotopesNeutron fluxNuclear ReactorsGermanyHumansNeutronIrradiationBoronRadiationPhantoms ImagingRadiotherapy Planning Computer-AssistedRadiochemistryLiver NeoplasmsGamma rayLiver TransplantationTransplantationEnergy TransferGamma RaysLithium CompoundsThermoluminescent DosimetryThermoluminescent dosimeterApplied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
researchProduct

Joint image and motion reconstruction for PET using a B-spline motion model.

2012

We present a novel joint image and motion reconstruction method for PET. The method is based on gated data and reconstructs an image together with a motion function. The motion function can be used to transform the reconstructed image to any of the input gates. All available events (from all gates) are used in the reconstruction. The presented method uses a B-spline motion model, together with a novel motion regularization procedure that does not need a regularization parameter (which is usually extremely difficult to adjust). Several image and motion grid levels are used in order to reduce the reconstruction time. In a simulation study, the presented method is compared to a recently propos…

Radiological and Ultrasound TechnologyDiscretizationbusiness.industryPhantoms ImagingB-splineMovementComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONMotion (geometry)Regularization (mathematics)Models BiologicalQuarter-pixel motionMotion fieldMotion estimationPositron-Emission TomographyDisplacement fieldImage Processing Computer-AssistedHumansRadiology Nuclear Medicine and imagingComputer visionJointsArtificial intelligencebusinessComputingMethodologies_COMPUTERGRAPHICSMathematicsPhysics in medicine and biology
researchProduct

Monte Carlo dosimetric study of the BEBIG Co-60 HDR source

2005

Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…

Radiological and Ultrasound TechnologyPhantoms ImagingComputer scienceRadiotherapy Planning Computer-AssistedBrachytherapyMonte Carlo methodWaterRadiotherapy DosageHigh-Dose Rate BrachytherapyMonte carlo codeAnisotropyHumansRadiology Nuclear Medicine and imagingCobalt RadioisotopesRadiometryRadiation treatment planningDose rateMonte Carlo MethodAlgorithmSoftwareSimulationPhysics in Medicine and Biology
researchProduct

End-to-end tests using alanine dosimetry in scanned proton beams

2018

This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…

Radiology Nuclear Medicine and ImagingMaterials sciencePelviMonte Carlo methodanthropomorphic phantomauditRadiation DosageImaging phantom030218 nuclear medicine & medical imaginglaw.inventionPelvisSynchrotron03 medical and health sciences0302 clinical medicinelawIonizationend to end testDosimetryHumansPencil-beam scanningRadiometryAlaninedosimetryRadiological and Ultrasound TechnologyPhantoms ImagingRadiotherapy Planning Computer-Assistedequipment and suppliesSynchrotron030220 oncology & carcinogenesisIonization chamberProtonProtonsHeadMonte Carlo MethodBeam (structure)SynchrotronsBiomedical engineeringHuman
researchProduct

A fully automatic approach for multimodal PET and MR image segmentation in gamma knife treatment planning

2017

The aim of this study is to combine Biological Target Volume (BTV) segmentation and Gross Target Volume (GTV) segmentation in stereotactic neurosurgery.Our goal is to enhance Clinical Target Volume (CTV) definition, including metabolic and morphologic information, for treatment planning and patient follow-up.We propose a fully automatic approach for multimodal PET and MR image segmentation. This method is based on the Random Walker (RW) and Fuzzy C-Means clustering (FCM) algorithms. A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is presented, considering volume…

Radiotherapy PlanningBrain tumorHealth Informatics02 engineering and technologyFuzzy C-means clusteringRadiosurgeryBrain tumorsMultimodal ImagingING-INF/05 - SISTEMI DI ELABORAZIONE DELLE INFORMAZIONI030218 nuclear medicine & medical imaging03 medical and health sciencesComputer-Assisted0302 clinical medicineRandom walker algorithm0202 electrical engineering electronic engineering information engineeringHumansMedicineSegmentationComputer visionRadiation treatment planningCluster analysisImage resolutionPET/MR imagingModality (human–computer interaction)Brain Neoplasmsbusiness.industryRadiotherapy Planning Computer-AssistedINF/01 - INFORMATICAMultimodal therapymedicine.diseaseRandom Walker algorithmMagnetic Resonance ImagingComputer Science ApplicationsBrain tumorGamma knife treatmentPositron-Emission Tomography020201 artificial intelligence & image processingMultimodal image segmentationBrain tumors; Fuzzy C-means clustering; Gamma knife treatments; Multimodal image segmentation; PET/MR imaging; Random Walker algorithm; Brain Neoplasms; Humans; Radiosurgery; Magnetic Resonance Imaging; Multimodal Imaging; Positron-Emission Tomography; Radiotherapy Planning Computer-AssistedArtificial intelligencebusinessGamma knife treatmentsSoftware
researchProduct

Regularization operators for natural images based on nonlinear perception models.

2006

Image restoration requires some a priori knowledge of the solution. Some of the conventional regularization techniques are based on the estimation of the power spectrum density. Simple statistical models for spectral estimation just take into account second-order relations between the pixels of the image. However, natural images exhibit additional features, such as particular relationships between local Fourier or wavelet transform coefficients. Biological visual systems have evolved to capture these relations. We propose the use of this biological behavior to build regularization operators as an alternative to simple statistical models. The results suggest that if the penalty operator take…

Regularization perspectives on support vector machinesInformation Storage and RetrievalImage processingRegularization (mathematics)Pattern Recognition AutomatedOperator (computer programming)Artificial IntelligenceImage Interpretation Computer-AssistedCluster AnalysisComputer SimulationImage restorationMathematicsModels Statisticalbusiness.industryWavelet transformSpectral density estimationStatistical modelPattern recognitionNumerical Analysis Computer-AssistedSignal Processing Computer-AssistedImage EnhancementComputer Graphics and Computer-Aided DesignNonlinear DynamicsArtificial intelligencebusinessSoftwareAlgorithmsIEEE transactions on image processing : a publication of the IEEE Signal Processing Society
researchProduct

[Current developments and perspectives on the diagnosis and treatment of urinary incontinence and genital prolapse in women].

2012

As a key area of gynaecology, urogynaecology has undergone impressive changes in the past few years. Together with the high prevalence of functional pelvic floor disorders, modern anaesthesia procedures and the introduction of new, innovative minimally invasive operation techniques have led to a dramatic increase in the number of operations for incontinence and prolapses. The increasingly subtle diagnostic options, such as, e. g., 2D and 3D sonography of the pelvic floor provide unambiguous findings and facilitate decision making. Tension-free vaginal slings in retro-pubic, trans-obturator or single-incision techniques show a high success rate with few complications and have almost complete…

Reoperationmedicine.medical_specialtyStress incontinenceUrinary Incontinence StressUrinary incontinencePelvic floor surgeryPelvic Floor DisordersArticleUrogynecologyImaging Three-DimensionalPostoperative ComplicationsRecurrenceUterine ProlapseGermanyMaternity and MidwiferyImage Interpretation Computer-AssistedmedicineHumansMinimally Invasive Surgical ProceduresSex organUltrasonographySuburethral SlingsPelvic floorHigh prevalencebusiness.industryGeneral surgeryObstetrics and GynecologySurgical Meshmedicine.diseaseSurgeryClinical trialmedicine.anatomical_structureFemaleClinical CompetenceCurriculummedicine.symptombusinessAktuelle Urologie
researchProduct

Ki-67 assessment of pancreatic neuroendocrine neoplasms: Systematic review and meta-analysis of manual vs. digital pathology scoring

2022

Ki-67 assessment is a key step in the diagnosis of neuroendocrine neoplasms (NENs) from all anatomic locations. Several challenges exist related to quantifying the Ki-67 proliferation index due to lack of method standardization and inter-reader variability. The application of digital pathology coupled with machine learning has been shown to be highly accurate and reproducible for the evaluation of Ki-67 in NENs. We systematically reviewed all published studies on the subject of Ki-67 assessment in pancreatic NENs (PanNENs) employing digital image analysis (DIA). The most common advantages of DIA were improvement in the standardization and reliability of Ki-67 evaluation, as well as its spee…

Reproducibility of ResultsBreast NeoplasmsCarcinoid TumorPathology and Forensic MedicinePancreatic Neoplasmsneuroendocrine neoplasms pancreasNeuroendocrine TumorsKi-67 AntigenGastroenteropancreatic Neuroendocrine TumorBiomarkers TumorImage Processing Computer-AssistedHumansGastroenteropancreatic Neuroendocrine Tumor; Cancer; Carcinoid TumorFemaleCell ProliferationCancer
researchProduct