Search results for " Computer-Assisted"
showing 10 items of 1033 documents
The modulation transfer function and signal-to-noise ratio of different digital filters: a technical approach.
2011
The aim of this study was to illustrate the influence of digital filters on the signal-to-noise ratio (SNR) and modulation transfer function (MTF) of digital images. The article will address image pre-processing that may be beneficial for the production of clinically useful digital radiographs with lower radiation dose.Three filters, an arithmetic mean filter, a median filter and a Gaussian filter (standard deviation (SD) = 0.4), with kernel sizes of 3 × 3 pixels and 5 × 5 pixels were tested. Synthetic images with exactly increasing amounts of Gaussian noise were created to gather linear regression of SNR before and after application of digital filters. Artificial stripe patterns with defin…
Monte Carlo dosimetric study of the medium dose rate CSM40 source
2013
Abstract The 137Cs medium dose rate (MDR) CSM40 source model (Eckert & Ziegler BEBIG, Germany) is in clinical use but no dosimetric dataset has been published. This study aims to obtain dosimetric data for the CSM40 source for its use in clinical practice as required by the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO). Penelope2008 and Geant4 Monte Carlo codes were used to characterize this source dosimetrically. It was located in an unbounded water phantom with composition and mass density as recommended by AAPM and ESTRO. Due to the low photon energies of 137Cs, absorbed dose was approximated by collisional kerma. Add…
Determination of the irradiation field at the research reactor TRIGA Mainz for BNCT.
2009
For the application of the BNCT for the excorporal treatment of organs at the TRIGA Mainz, the basic characteristics of the radiation field in the thermal column as beam geometry, neutron and gamma ray energies, angular distributions, neutron flux, as well as absorbed gamma and neutron doses must be determined in a reproducible way. To determine the mixed irradiation field thermoluminescence detectors (TLD) made of CaF(2):Tm with a newly developed energy-compensation filter system and LiF:Mg,Ti materials with different (6)Li concentrations and different thicknesses as well as thin gold foils were used.
Joint image and motion reconstruction for PET using a B-spline motion model.
2012
We present a novel joint image and motion reconstruction method for PET. The method is based on gated data and reconstructs an image together with a motion function. The motion function can be used to transform the reconstructed image to any of the input gates. All available events (from all gates) are used in the reconstruction. The presented method uses a B-spline motion model, together with a novel motion regularization procedure that does not need a regularization parameter (which is usually extremely difficult to adjust). Several image and motion grid levels are used in order to reduce the reconstruction time. In a simulation study, the presented method is compared to a recently propos…
Monte Carlo dosimetric study of the BEBIG Co-60 HDR source
2005
Although not as widespread as Ir-192, Co-60 is also available on afterloading equipment devoted to high dose rate brachytherapy, mainly addressed to the treatment of gynaecological lesions. The purpose of this study is to obtain the dosimetric parameters of the Co-60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there are no dosimetric data available in the literature. The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2D dose rate table in Cartesian coordinates of the BEBIG Co-60 HDR source. The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in a tabular form as w…
End-to-end tests using alanine dosimetry in scanned proton beams
2018
This paper describes end-to-end test procedures as the last fundamental step of medical commissioning before starting clinical operation of the MedAustron synchrotron-based pencil beam scanning (PBS) therapy facility with protons. One in-house homogeneous phantom and two anthropomorphic heterogeneous (head and pelvis) phantoms were used for end-to-end tests at MedAustron. The phantoms were equipped with alanine detectors, radiochromic films and ionization chambers. The correction for the 'quenching' effect of alanine pellets was implemented in the Monte Carlo platform of the evaluation version of RayStation TPS. During the end-to-end tests, the phantoms were transferred through the workflow…
A fully automatic approach for multimodal PET and MR image segmentation in gamma knife treatment planning
2017
The aim of this study is to combine Biological Target Volume (BTV) segmentation and Gross Target Volume (GTV) segmentation in stereotactic neurosurgery.Our goal is to enhance Clinical Target Volume (CTV) definition, including metabolic and morphologic information, for treatment planning and patient follow-up.We propose a fully automatic approach for multimodal PET and MR image segmentation. This method is based on the Random Walker (RW) and Fuzzy C-Means clustering (FCM) algorithms. A total of 19 brain metastatic tumors, undergone stereotactic neuro-radiosurgery, were retrospectively analyzed. A framework for the evaluation of multimodal PET/MRI segmentation is presented, considering volume…
Regularization operators for natural images based on nonlinear perception models.
2006
Image restoration requires some a priori knowledge of the solution. Some of the conventional regularization techniques are based on the estimation of the power spectrum density. Simple statistical models for spectral estimation just take into account second-order relations between the pixels of the image. However, natural images exhibit additional features, such as particular relationships between local Fourier or wavelet transform coefficients. Biological visual systems have evolved to capture these relations. We propose the use of this biological behavior to build regularization operators as an alternative to simple statistical models. The results suggest that if the penalty operator take…
[Current developments and perspectives on the diagnosis and treatment of urinary incontinence and genital prolapse in women].
2012
As a key area of gynaecology, urogynaecology has undergone impressive changes in the past few years. Together with the high prevalence of functional pelvic floor disorders, modern anaesthesia procedures and the introduction of new, innovative minimally invasive operation techniques have led to a dramatic increase in the number of operations for incontinence and prolapses. The increasingly subtle diagnostic options, such as, e. g., 2D and 3D sonography of the pelvic floor provide unambiguous findings and facilitate decision making. Tension-free vaginal slings in retro-pubic, trans-obturator or single-incision techniques show a high success rate with few complications and have almost complete…
Ki-67 assessment of pancreatic neuroendocrine neoplasms: Systematic review and meta-analysis of manual vs. digital pathology scoring
2022
Ki-67 assessment is a key step in the diagnosis of neuroendocrine neoplasms (NENs) from all anatomic locations. Several challenges exist related to quantifying the Ki-67 proliferation index due to lack of method standardization and inter-reader variability. The application of digital pathology coupled with machine learning has been shown to be highly accurate and reproducible for the evaluation of Ki-67 in NENs. We systematically reviewed all published studies on the subject of Ki-67 assessment in pancreatic NENs (PanNENs) employing digital image analysis (DIA). The most common advantages of DIA were improvement in the standardization and reliability of Ki-67 evaluation, as well as its spee…