Search results for " Computer-Assisted"
showing 10 items of 1033 documents
Scanning from heating: 3D shape estimation of transparent objects from local surface heating.
2009
Today, with quality becoming increasingly important, each product requires three-dimensional in-line quality control. On the other hand, the 3D reconstruction of transparent objects is a very difficult problem in computer vision due to transparency and specularity of the surface. This paper proposes a new method, called Scanning From Heating (SFH), to determine the surface shape of transparent objects using laser surface heating and thermal imaging. Furthermore, the application to transparent glass is discussed and results on different surface shapes are presented.
Boolean operations with implicit and parametric representation of primitives using R-functions
2005
We present a new and efficient algorithm to accurately polygonize an implicit surface generated by multiple Boolean operations with globally deformed primitives. Our algorithm is special in the sense that it can be applied to objects with both an implicit and a parametric representation, such as superquadrics, supershapes, and Dupin cyclides. The input is a constructive solid geometry tree (CSG tree) that contains the Boolean operations, the parameters of the primitives, and the global deformations. At each node of the CSG tree, the implicit formulations of the subtrees are used to quickly determine the parts to be transmitted to the parent node, while the primitives' parametric definition …
Quantification of Lung Volume at Different Tidal Volumes and Positive End-Expiratory Pressures in a Porcine Model by Using Retrospective Respiratory …
2008
PURPOSE: This feasibility study in healthy animals should prove the concept that it is possible to quantitatively assess the effects of different ventilatory settings on the lung parenchyma during ongoing ventilation in respiratory gated 4-dimensional (D)-computed tomography (CT). For this purpose, the influence of different tidal volumes and positive end-expiratory pressure (PEEP) on quantitative assessment of lung volumes (LVs) and lung compartments was analyzed. METHODS: Five anesthetized and ventilated (20 breaths/min, inspiratory/expiratory ratio of 1:2) healthy pigs underwent 16-row multidetector CT with retrospective respiratory gating using a noncontact charge-coupled device camera …
About Objective 3-D Analysis of Airway Geometry in Computerized Tomography
2008
The technology of multislice X-ray computed tomography (MSCT) provides volume data sets with approximately isotropic resolution, which permits a noninvasive 3-D measurement and quantification of airway geometry. In different diseases, like emphysema, chronic obstructive pulmonary disease (COPD), or cystic fribrosis, changes in lung parenchyma are associated with an increase in airway wall thickness. In this paper, we describe an objective measuring method of the airway geometry in the 3-D space. The limited spatial resolution of clinical CT scanners in comparison to thin structures like airway walls causes difficulties in the measurement of the density and the thickness of these structures.…
Analysis of discrete and continuous distributions of ventilatory time constants from dynamic computed tomography.
2005
In this study, an algorithm was developed to measure the distribution of pulmonary time constants (TCs) from dynamic computed tomography (CT) data sets during a sudden airway pressure step up. Simulations with synthetic data were performed to test the methodology as well as the influence of experimental noise. Furthermore the algorithm was applied to in vivo data. In five pigs sudden changes in airway pressure were imposed during dynamic CT acquisition in healthy lungs and in a saline lavage ARDS model. The fractional gas content in the imaged slice (FGC) was calculated by density measurements for each CT image. Temporal variations of the FGC were analysed assuming a model with a continuous…
Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging.
2010
Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The pr…
Surpassing digital holography limits by lensless object scanning holography.
2012
We present lensless object scanning holography (LOSH) as a fully lensless method, capable of improving image quality in reflective digital Fourier holography, by means of an extremely simplified experimental setup. LOSH is based on the recording and digital post-processing of a set of digital lensless holograms and results in a synthetic image with improved resolution, field of view (FOV), signal-to-noise ratio (SNR), and depth of field (DOF). The superresolution (SR) effect arises from the generation of a synthetic aperture (SA) based on the linear movement of the inspected object. The same scanning principle enlarges the object FOV. SNR enhancement is achieved by speckle suppression and c…
Robust three-dimensional best-path phase-unwrapping algorithm that avoids singularity loops.
2009
In this paper we propose a novel hybrid three-dimensional phase-unwrapping algorithm, which we refer to here as the three-dimensional best-path avoiding singularity loops (3DBPASL) algorithm. This algorithm combines the advantages and avoids the drawbacks of two well-known 3D phase-unwrapping algorithms, namely, the 3D phase-unwrapping noise-immune technique and the 3D phase-unwrapping best-path technique. The hybrid technique presented here is more robust than its predecessors since it not only follows a discrete unwrapping path depending on a 3D quality map, but it also avoids any singularity loops that may occur in the unwrapping path. Simulation and experimental results have shown that …
An identifiable model to assess frequency-domain Granger causality in the presence of significant instantaneous interactions
2010
We present a new approach for the investigation of Granger causality in the frequency domain by means of the partial directed coherence (PDC). The approach is based on the utilization of an extended multivariate autoregressive (MVAR) model, including instantaneous effects in addition to the lagged effects traditionally studied, to fit the observed multiple time series prior to PDC computation. Model identification is performed combining standard MVAR coefficient estimation with a recent technique for instantaneous causal modeling based on independent component analysis. The approach is first validated on simulated MVAR processes showing that, in the presence of instantaneous effects, only t…
Non-invasive localization of atrial ectopic beats by using simulated body surface P-wave integral maps
2017
Non-invasive localization of continuous atrial ectopic beats remains a cornerstone for the treatment of atrial arrhythmias. The lack of accurate tools to guide electrophysiologists leads to an increase in the recurrence rate of ablation procedures. Existing approaches are based on the analysis of the P-waves main characteristics and the forward body surface potential maps (BSPMs) or on the inverse estimation of the electric activity of the heart from those BSPMs. These methods have not provided an efficient and systematic tool to localize ectopic triggers. In this work, we propose the use of machine learning techniques to spatially cluster and classify ectopic atrial foci into clearly diffe…