Search results for " Computer"
showing 10 items of 6910 documents
A fully automatic 2D segmentation method for uterine fibroid in MRgFUS treatment evaluation
2015
PurposeMagnetic Resonance guided Focused UltraSound (MRgFUS) represents a non-invasive surgical approach that uses thermal ablation to treat uterine fibroids. After the MRgFUS treatment, an operator must manually segment the treated fibroid areas to evaluate the NonPerfused Volume (NPV). This manual approach is operator-dependent, introducing issues of result reproducibility, which could lead to errors in the subsequent follow-up phase. Moreover, manual segmentation is time-consuming, and can have a negative impact on the optimization of both machine-time and operator-time. MethodTo address these issues, in this paper a novel fully automatic method based on the unsupervised Fuzzy C-Means cl…
Online Professionalism-2018 Update of European Association of Urology (@Uroweb) Recommendations on the Appropriate Use of Social Media.
2018
Abstract Context Social media (SoMe) has transformed communication among health care professionals by enabling rapid and global information exchange. Yet, the novelty of SoMe and concerns about potential risks continue to be barriers to adoption. Objective To encourage appropriate professional use of SoMe by physicians in concordance with best practices and to update practical guidelines for effective and professional use of these communication technologies. Evidence aquisition The European Association of Urology (EAU; @Uroweb) brought together a committee of SoMe stakeholders in the urology field. PubMed and the grey literature were searched to identify SoMe position papers by other medica…
Histometric investigations of placental villi in cases of unexpected fetal acidosis.
1994
It is not unusual that, after an apparently uneventful pregnancy and birth, postpartal analysis of fetal blood unexpectedly reveals the presence of peripartal acidosis, a finding that is inexplicable on the basis of routine observation of the placenta. Using computer-assisted histometric procedures, it is possible to make a quantitative assessment with respect to the maturity and differentiation of villi, thus casting light on the functional anatomy of these structures. 89 single-birth pregnancies were grouped in accordance to the pH of blood in the umbilical artery (pre-acidosis, acidosis, non acidotic). In acidotic newborns, there is an absolute reduction in the surface area of the placen…
Discrimination of early/intermediate and advanced/complicated coronary plaque types by radiofrequency intravascular ultrasound analysis
2002
Radiofrequency intravascular ultrasound (IVUS-RF) analysis, as an extension of conventional IVUS imaging, may provide more accurate plaque discrimination. Thirty-two autopsy atherosclerotic coronary arteries were investigated. Corresponding sectors in different plaques were matched by histologic and RF analysis. Histologic analysis utilized the American Heart Association plaque classification. The backscattered ultrasound RF signal was analyzed by fast-Fourier transform, providing the underlying frequency components of its power spectrum. The normalized backscattered signal power (in decibels [dB]) for frequencies between 15.3 and 40.3 MHz was then measured for plaque discrimination. Advanc…
Studying hypertension in ocular fundus images using Hausdorff dispersion ordering.
2010
Retinal arterial and vein diameters are altered in individuals at risk of cardiovascular events mainly due to high blood pressure. The measurement of retinal vessel diameters has been proved to reflect individuals' vascular health. Dispersion of such measures which are obtained by means of ocular fundus images is a major factor not usually considered in clinical research. In this paper, a method to evaluate if different levels of clinically relevant covariables induce greater dispersion in retinal arterial and vein diameters is proposed. A multivariate dispersion ordering, the Hausdorff dispersion order, is used to compare the level of dispersion in such diameters for different groups of pa…
Exclusive MRI-based tandem and colpostats reconstruction in gynaecological brachytherapy treatment planning
2008
Purpose: According to the GYN GEC-ESTRO Recommendations, MRI is needed with the modality of T2 weighted. CT-MR compatible tandem Plus colpostats (T/C) (Nucletron) is widely used in cervical brachytherapy. The major challenge of MRI is the lack of dummy catheters. Therefore, an additional imaging modality is usually required. One disadvantage of sliced-based reconstruction is that resolution in longitudinal directions can be affected by the slice thickness. The aim of this study is to present a modified T/C applicator in which the catheter visibility is significantly improved. Methods and materials: A modification to the existing T/C applicator has been made available, increasing the cathete…
Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.
2013
HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.
Automatic detection of lung nodules in CT datasets based on stable 3D mass–spring models
2012
We propose a computer-aided detection (CAD) system which can detect small-sized (from 3 mm) pulmonary nodules in spiral CT scans. A pulmonary nodule is a small lesion in the lungs, round-shaped (parenchymal nodule) or worm-shaped (juxtapleural nodule). Both kinds of lesions have a radio-density greater than lung parenchyma, thus appearing white on the images. Lung nodules might indicate a lung cancer and their early stage detection arguably improves the patient survival rate. CT is considered to be the most accurate imaging modality for nodule detection. However, the large amount of data per examination makes the full analysis difficult, leading to omission of nodules by the radiologist. We…
A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model
2007
A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce…
MUSCLE BIOENERGETICS IN OBESE ZUCKER RATS
1994
International audience; Abstract: The purpose of this study was to investigate the energetic metabolism in obese Zucker rats, using phosphorus nuclear magnetic resonance spectroscopy at rest and during a 2-Hz muscle stimulation and subsequent recovery. Animals were anesthetized with ketamine (150 mg/kg ip). Fed obese rats and 2-day-fasted obese rats were compared with their normally fed and 2-day-fasted lean litter mates. No differences were found between the two groups for ATP, total creatine, phosphocreatine (PCr), and intracellular pH. Starvation in lean rats resulted in a significant fall in inorganic phosphate (Pi), increased resting ADP level, and decreased PCr and ADP recovery after …