Search results for " Computer"
showing 10 items of 6910 documents
Video-assisted two-stage basilic vein transposition for creation of brachio-basilic arteriovenous fistulae
2012
We report our experience in a mixed minimally-in- vasive technique for the two-stage transposition of basilic vein on a small series of eight patients. The operative tech- nique consisted of a modified endoscopic (1) approach for the two-stage transposition (2). The intervention was performed under Brachial Plexus Block (3).
Transcatheter embolization of a large aberrant systemic artery to an intralobar pulmonary sequestration using an Amplatzer vascular plug in an adoles…
2017
International audience
What is the accuracy of the surgical guide in the planning of orthognathic surgeries? A systematic review.
2021
BACKGROUND To investigate the true accuracy of the surgical guide in the planning of orthognathic surgeries, which are performed worldwide. MATERIAL AND METHODS A systematic search was conducted in the PubMed database, Web of science, Scopus and Embase, covering August 2020 to January 2021. Studies that included patients with dentofacial deformity including anteroposterior, vertical and asymmetry problems who were undergoing an orthognathic surgery procedure were included; QUADAS-2 was used to determine the risk of bias by analyzing the quality of the studies. A PRISMA (flowchart) was created to show the study selection, keywords, nomination processes, and inclusion and exclusion criteria. …
Implant-specific follow-up imaging of treated intracranial aneurysms: TOF-MRA vs. metal artifact reduced intravenous flat panel computed tomography a…
2017
Aim To compare the diagnostic quality of time-of-flight magnetic resonance angiography (TOF-MRA) and metal-artefact-reduction (MAR) flat-panel-detector computed tomography angiography (FPCTA) and to determine the imaging technique best suited for evaluation endovascular and surgically treated aneurysms. Methods The image quality of TOF-MRA and MAR-FPCTA of 44 intracranial implants (coiling: n= 20; clipping: n= 15; coiling + stenting: n= 9) in a patient cohort of 25 was evaluated by two independent readers. Images obtained using MAR-FPCTA (20 second scan time, 496 projections, intravenous contrast medium administration; Artis Zee, Siemens Healthcare, Forchheim) were compared with TOF-MRA-ima…
Recurrence quantification analysis as a tool for complex fractionated atrial electrogram discrimination
2012
International audience; Atrial fibrillation is the most encountered pathology of the heart rate. The reasons of its occurrence and its particular characteristics remain unknown, resulting from complex phenomena interaction. From these interactions emerges Complex Fractionated Atrial Electrograms (CFAE) which are useful for the ablation procedure. This study presents a method based on nonlinear data analysis, the Recurrence Quantification Analysis (RQA) applied on intracardiac atrial electrograms to detect CFAE particularities. The results obtained on areas previously tagged by a cardilogist show a good sensitivity to CFAE. Combination of RQA features offers a larger discrimination potential…
Reaching and Grasping a Glass of Water by Locked-In ALS Patients through a BCI-Controlled Humanoid Robot
2017
Locked-in Amyotrophic Lateral Sclerosis (ALS) patients are fully dependent on caregivers for any daily need. At this stage, basic communication and environmental control may not be possible even with commonly used augmentative and alternative communication devices. Brain Computer Interface (BCI) technology allows users to modulate brain activity for communication and control of machines and devices, without requiring a motor control. In the last several years, numerous articles have described how persons with ALS could effectively use BCIs for different goals, usually spelling. In the present study, locked-in ALS patients used a BCI system to directly control the humanoid robot NAO (Aldebar…
Spectral decomposition of RR-variability obtained by an open loop parametric model for the diagnosis of neuromediate syncope
2002
The role of the cardiovascular regulatory mechanism in patients with neuromediate syncope (NS) is poorly understood. The aim of this study was to accomplish continuous non-invasive analysis of the baroreflex mechanism in patients during a head-tip tilt-table test (HTT) using an open-loop autoregressive model with exogenous input. The model describes the causal dependence of the RR interval on the systolic arterial pressure (SAP) variability. Thus, RR variability results as the linear composition of SAP-dependent (Pdep) and SAP-independent parts of the RR power (P). Further, the model allows the estimation of the baroreflex gain using the modulus of the transfer function (G) from SAP to RR i…
Synchronization index for quantifying nonlinear causal coupling between RR interval and systolic arterial pressure after myocardial infarction
2002
The analysis of nonlinear couplings among cardiovascular variability series can improve the knowledge of the cardioregulatory mechanism and help to understand how it can be affected by pathologies. In this study, the influences of acute myocardial infarction (AMI) on the causal relationships between the heart period and the arterial pressure were investigated by a nonlinear dynamic approach based on the corrected cross-conditional entropy. Whereas the global synchronization index did not differentiate the post-AMI patients from the young and old control groups, the causal indexes evidenced the impairment of the baroreflex control and showed an increase of the mechanical driving of the RR in…
Recognition of rapid-eye-movement sleep from single-channel EEG data by artificial neural networks: a study in depressive patients with and without a…
1996
An automatic procedure for the online recognition of REM sleep appears to be a necessary tool for selective REM sleep deprivation in depressive patients. To develop such a procedure we applied an artificial neural network to preprocessed single-channel EEG activity. EOG and EMG information was purposely not provided as input to the network. A generalized back-propagation algorithm was used for computer simulation. The sleep profile scored manually according to Rechtschaffen and Kales served as the desired output during the training period and as standard for the judgement of the network output during working mode. Polysomnographic recordings from 5 healthy subjects were pooled to train the …
Use of neural networks for dosage individualisation of erythropoietin in patients with secondary anemia to chronic renal failure.
2003
The external administration of recombinant human erythropoietin is the chosen treatment for those patients with secondary anemia due to chronic renal failure undergoing periodic hemodialysis. The goal is to carry out an individualised prediction of the erythropoietin dosage to be administered. It is justified because of the high cost of this medication, its secondary effects and the phenomenon of potential resistance which some individuals suffer. One hundred and ten patients were included in this study and several factors were collected in order to develop the neural models. Since the results obtained were excellent, an easy-to-use decision-aid computer application was implemented.