Search results for " Computer"
showing 10 items of 6910 documents
Appropriateness guidelines and predictive rules to select patients for upper endoscopy: a nationwide multicenter study.
2010
OBJECTIVES: Selecting patients appropriately for upper endoscopy (EGD) is crucial for efficient use of endoscopy. The objective of this study was to compare different clinical strategies and statistical methods to select patients for EGD, namely appropriateness guidelines, age and/or alarm features, and multivariate and artificial neural network (ANN) models. METHODS: A nationwide, multicenter, prospective study was undertaken in which consecutive patients referred for EGD during a 1-month period were enrolled. Before EGD, the endoscopist assessed referral appropriateness according to the American Society for Gastrointestinal Endoscopy (ASGE) guidelines, also collecting clinical and demogra…
Recognition of Root Canal Orifices in Video Sequences as a Future Support System During Endodontic Treatment
2009
Abstract Introduction The objective of this study was to show the practical application of computer-aided techniques for detecting root canal orifices through the access cavity using a video camera mounted on a microscope. Methods A minimum distance classification image recognition algorithm was tested in an in vitro study to assess the possibilities of computer-aided recognition of root canal orifices. A Motic DM143 digital stereo microscope (Motic Germany GmbH, Wetzlar, Germany) was used because it includes a video camera that can be connected via USB1.1 to any computer. Results The newly developed software is capable of communicating with a video camera and can automatically detect the r…
Surrogate data approaches to assess the significance of directed coherence: Application to EEG activity propagation
2009
This paper addresses the topic of evaluating the significance of frequency domain measures of causal coupling in multivariate time series through generation of surrogate data. The considered approaches are the traditional Fourier Transform (FT) algorithm and a new causal FT (CFT) algorithm for surrogate data generation. Both algorithms preserve the FT modulus of the original series; differences are in the phase relationships, that are completely destroyed for FT surrogates and imposed after switching off the link over the considered causal direction for CFT surrogates. The ability of the algorithms to assess causality in the frequency domain was tested using the directed coherence as discri…
Testing Frequency-Domain Causality in Multivariate Time Series
2010
We introduce a new hypothesis-testing framework, based on surrogate data generation, to assess in the frequency domain, the concept of causality among multivariate (MV) time series. The approach extends the traditional Fourier transform (FT) method for generating surrogate data in a MV process and adapts it to the specific issue of causality. It generates causal FT (CFT) surrogates with FT modulus taken from the original series, and FT phase taken from a set of series with causal interactions set to zero over the direction of interest and preserved over all other directions. Two different zero-setting procedures, acting on the parameters of a MV autoregressive (MVAR) model fitted on the ori…
Validation of tumour-free distance as novel prognostic marker in early-stage cervical cancer: a retrospective, single-centre, cohort study
2021
Background: The aim of the present study was to assess the prognostic value of tumour-free distance (TFD), defined as the minimum distance of uninvolved stroma between the tumour and peri-cervical stromal ring, in early-stage cervical cancer. Methods: Patients with pathologic FIGO 2009 stage IA1–IIA2 cervical cancer, treated by primary radical surgical treatment between 01/2000 and 11/2019, were retrospectively included. Adjuvant treatment was administered according to the presence of previously established pathologic risk factors. TFD was measured histologically on the hysterectomy specimen. Pre-operative TFD measured at MRI-scan from a cohort of patients was reviewed and compared with pat…
Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths
2016
The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…
Reference Ranges and Distribution of Placental Volume by 3-Dimensional Virtual Organ Computer-Aided Analysis Between 11 Weeks and 13 Weeks 6 Days
2013
OBJECTIVES The purpose of this study was to determine the feasibility, reproducibility, and distribution of placental volume measurements according to the crown-rump length between 11 weeks and 13 weeks 6 days. METHODS Images were acquired in 128 pregnancies followed in Burgundy during first-trimester screening sonography using an abdominal 3-dimensional transducer. The placental volume was then calculated by the virtual organ computer-aided analysis method with a rotation angle of 30° by a single operator. RESULTS Placental volumes ranged from 33.3 to 107.6 cm(3) with a mean ± SD of 62.3 ± 14.8 cm(3); the 5th and 10th percentiles were 38.0 and 44.20 cm(3), respectively, whereas the 90th an…
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
Automatic Detection of Left Ventricular Contours from Cardiac Cine Magnetic Resonance Imaging Using Fuzzy Logic
1999
Gated cardiac cine magnetic resonance imaging provides accurate dynamic data of the left ventricular function. However, the manual extraction of important physiologic parameters such as myocardium wall thickness and left ventricular volumes is invariably time consuming and subjective. To reduce the variability and time constraints inherent in observer contour tracing, the authors developed an automatic left ventricle contour-detection method.The purpose was to apply fuzzy logic-based automatic contour detection to identification of endocardial and epicardial borders in short-axis magnetic resonance images. The automatic contouring was compared with manual tracing using the calculated ejecti…
Automatic determination of aortic compliance with cine-magnetic resonance imaging - An application of fuzzy logic theory
2002
International audience; Abstract: RATIONALE AND OBJECTIVES. Aortic compliance is defined as the relative change in aortic cross-sectional area divided by the change in arterial pressure. Magnetic resonance imaging (MRI) is a useful imaging modality for the noninvasive evaluation of aortic compliance. However, manual tracing of the aortic contour is subject to important interobserver variations. To estimate the aortic compliance from cine-MRI, a method based on fuzzy logic theory was elaborated. MATERIALS AND METHODS. Seven healthy volunteers and eight patients with Marfan syndrome were examined using an ECG gated cine-MRI sequence. The aorta was imaged in the transverse plane at the level o…