Casteldaccia eye study: prevalence of cataract in the adult and elderly population of a Mediterranean town.

1994

Prevalence of cataract was studied in a population based survey performed in adults aged 40 years or more living in Casteldaccia, a small Sicilian town. Lens opacities of moderate or severe grade (type II or worse, according to the Lens Opacity Classification System II) were found at the following rates: nuclear opalescence in 18.5%, cortical cataract in 12.9%, posterior subcapsular cataract in 10.8%. All these types of cataract were much more frequent in the elderly population and were about 1.5 times more common in women than in men. Late cataract was found in about 1/3 of subjects aged 60 to 69 years, in 2/3 of subjects aged 70 or more, but rarely under 60 years of age. However, early ca…

AdultMalemedicine.medical_specialtyPediatricsVisual acuitygenetic structuresCortical cataractVisual AcuityCataractCataractsAge groupsElderly populationOphthalmologyEpidemiologyLens CrystallinemedicinePrevalenceHumansPopulation based surveySicilyAgedAged 80 and overbusiness.industryAge FactorsMiddle Agedmedicine.diseaseeye diseasesOphthalmologyFemalesense organsmedicine.symptomPosterior subcapsular cataractbusinessInternational ophthalmology
researchProduct

Endothelial cell loss after toric iris-fixated phakic intraocular lens implantation: three-year follow-up.

2007

ABSTRACT PURPOSE: To study quantitative changes in endothelial cell count after implantation of the toric iris-fixated phakic intraocular lens. METHODS: A prospective, non-randomized, self-controlled clinical trial was conducted of 40 eyes (28 myopic, 12 hyperopic) of 23 patients with high ametropia and astigmatism. Non-contact computer-assisted endothelial microscopy was performed before and I1 2, and 3 years after surgery. RESULTS: In the myopic group, mean preoperative endothelial cell count was 3179±531 cells/mm p 2 (range: 1800 to 3900 cells/mm2). The mean intraindividual endothelial cell loss was -1.83±2.25% (range: -9.09% to 0%) in the first year; -1.83+2.95% (range: -7.74% to 3.80%)…

AdultMalemedicine.medical_specialtyTime FactorsIrisCell CountAstigmatismPhakic intraocular lensEndothelial cell countCorneal DiseasesPostoperative ComplicationsLens Implantation IntraocularOphthalmologyLens CrystallineMedicineHumansProspective Studiesbusiness.industryEndothelium CornealSuture TechniquesMiddle Agedmedicine.diseaseCell lossRefractive Surgical ProceduresEndothelial stem cellOphthalmologySurgeryFemalebusinessFollow-Up StudiesJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Change in pupil size after implantation of an iris-fixated toric phakic intraocular lens

2005

Purpose To evaluate the changes in pupil size after implantation of an iris-supported toric phakic intraocular lens (TPIOL) for correction of myopia and hyperopia with astigmatism. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Twenty-two myopic eyes and 9 hyperopic eyes were included in the study. The mean age of the 2 groups was 34 years and 40 years, respectively. The scotopic pupil size was measured with a handheld infrared pupillometer (Colvard, Oasis Medical) before and 6 months after implantation of the TPIOL. All examinations were performed under scotopic conditions after 2 minutes of dark adaptation with the fellow eye covered. Intraindi…

AdultMalemedicine.medical_specialtygenetic structuresmedicine.medical_treatmentIrisMagnificationIntraocular lensAstigmatismProsthesis DesignPhakic intraocular lensPupilLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaMydriasismedicineHumansIris (anatomy)Lenses Intraocularbusiness.industrySuture TechniquesAstigmatismPupilMiddle Agedmedicine.diseaseeye diseasesSensory SystemsToric lensOphthalmologyHyperopiamedicine.anatomical_structureOptometryFemaleSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Effect of trypan blue on the elasticity of the human anterior lens capsule.

2007

Purpose To evaluate the effect of trypan blue (VisionBlue) staining on the elastic properties of the human anterior lens capsule. Setting Center for Vision Science, Ruhr University Eye Hospital, Bochum, Germany. Methods Nineteen anterior capsules were obtained from 19 human eyes at the time of cataract operation. Two same-size strips were prepared from each capsule; 1 was exposed to trypan blue staining for 10 seconds, and the other was a control. The elasticity measurements were performed on both specimens using a modified rheometer. Results The mean age of the patients was 75.3 years ± 13.3 (SD) (range 35 to 89 years). Sixty-three measurements of 19 suitable specimen pairs were performed.…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentLens Capsule Crystallinechemistry.chemical_compoundOphthalmologymedicineAnterior lens capsuleHumansProspective StudiesElasticity (economics)Coloring AgentsAgedAged 80 and overTreated groupbusiness.industryCapsuleVisionBlueTrypan BlueCataract surgeryMiddle AgedSensory SystemsElasticityStainingOphthalmologychemistrySurgeryTrypan blueFemaleStress MechanicalbusinessJournal of cataract and refractive surgery
researchProduct

Spectral transmission of the pig lens: Effect of ultraviolet A+B radiation

2014

Summary Objective To determine the spectral transmission curve of the crystalline lens of the pig. To analyse how this curve changes when the crystalline lens is irradiated with ultraviolet A + B radiation similar to that of the sun. To compare these results with literature data from the human crystalline lens. Procedures We used crystalline lenses of the common pig from a slaughterhouse, i.e. genetically similar pigs, fed with the same diet, and slaughtered at six months old. Spectral transmission was measured with a Perkin-Elmer Lambda 35 UV/VIS spectrometer. The lenses were irradiated using an Asahi Spectra Lax-C100 ultraviolet source, which made it possible to select the spectral emissi…

AdultMaterials scienceAnterior subcapsular cataractLightSwineUltraviolet RaysRadiationmedicine.disease_causeCataractSpectral linelaw.inventionOpticslawLens CrystallinemedicineAnimalsHumansScattering RadiationIrradiationSpectrometerbusiness.industrySpectrum Analysiseye diseasesLens (optics)OphthalmologyChild Preschoolsense organsbusinessUltravioletVisible spectrumJournal Français d'Ophtalmologie
researchProduct

Impact of the line of sight on toric phakic intraocular lenses for hyperopia

2003

We present a hyperopic patient with a decentered line of sight in whom the residual refractive error after toric phakic intraocular lens (TP IOL) implantation was improved by displacement and individualized treatment. A 35-year-old woman presented with asthenopic complaints 2 months after bilateral TP IOL implantation and IOL rotation 4 weeks later. Examination revealed the line of sight to be nasally and inferiorly decentered in relation to the center of the pupil. A more nasal reenclavation of the TP IOL decreased the coma, and the uncorrected visual acuity was 20/20. We conclude that line of sight should be measured before TP IOL implantation, especially in hyperopic eyes.

AdultReoperationRefractive errormedicine.medical_specialtygenetic structuresEye diseasemedicine.medical_treatmentVision DisordersVisual AcuityComa (optics)Intraocular lensUncorrected visual acuityPhakic intraocular lensPupilVision disorderForeign-Body MigrationLens Implantation IntraocularOphthalmologyLens CrystallinemedicineHumansbusiness.industryAstigmatismCorneal TopographyPupilmedicine.diseaseeye diseasesSensory SystemsOphthalmologyHyperopiaOptometryFemaleSurgeryAsthenopiasense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT

2021

Purpose To measure lens vault (LV) and to assess its correlation with various ocular parameters in healthy eyes, using for all measurements the same high-resolution swept-source optical coherence tomographer (SS-OCT). Methods We prospectively recruited 67 Caucasian healthy patients whose mean age was 41.9 ± 12.4 years; only their right eye was included in the study. Data were all recorded with the ANTERION SS-OCT and comprised, for each patient, 5 consecutive measurements of LV, anterior chamber depth (ACD), lens thickness (LT), axial length (AL), white-to-white (WTW) distance, central corneal thickness (CCT), anterior chamber volume (ACV) and spur-to-spur (STS) distance. Results Mean LV wa…

Adultmedicine.medical_specialtyBiometryAnterior ChamberSignificant negative correlationPositive correlationSwept-source Fourier domainCorrelationLens thicknessOphthalmologyLens CrystallineHumansMedicineOptical coherence tomographybusiness.industrySpur-to-spurReproducibility of ResultsMean ageAxial lengthWhite-to-whiteMiddle AgedClinical routineCrystalline lens riseAxial Length Eyemedicine.anatomical_structureLens (anatomy)Original ArticlebusinessTomography Optical CoherenceOptometryJournal of Optometry
researchProduct

Behaviour of the phakic iris-claw intraocular lens (Artisan /Verisyse) during accommodation: an optical coherence biometry study.

2007

Purpose To evaluate variations in the position of the phakic iris claw lens (Artisan®, Verisyse®) and the natural crystalline lens during the accommodation process. Methods We measured changes in position of the iris claw lens and the crystalline lens during the accommodation using optical coherence biometry (AC Master®/Carl Zeiss Meditec, Germany) in 17 patients (28 eyes) with a phakic iris claw lens implanted for high myopia and/or myopic astigmatism. Accommodative effort was obtained using an internal optical target within the measuring device. Results There was a forward shift of the phakic iris claw lens with a mean of 70 μm (8–178 μm) of the optical path length (OPL). At the same time…

Adultmedicine.medical_specialtyPhakic Intraocular LensesMaterials scienceBiometrymedicine.medical_treatmentIrisIntraocular lensRefraction OcularMyopic astigmatism03 medical and health sciences0302 clinical medicineOpticsLens Implantation IntraocularAnterior Eye SegmentOphthalmologyLens CrystallinemedicineMyopiaHumansIris clawOptical path lengthbusiness.industryHigh myopiaAccommodation OcularAstigmatismGeneral MedicineMiddle AgedOphthalmologymedicine.anatomical_structureLens (anatomy)030221 ophthalmology & optometrybusinessAccommodation030217 neurology & neurosurgeryTomography Optical CoherenceCoherence (physics)Follow-Up StudiesEuropean journal of ophthalmology
researchProduct

Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.

2005

To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage.Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany.In 92 eyes of 92 patients, a capsular measuring ring (CMR) was implanted after phacoemulsification to measure capsular bag size in vivo. Patients were randomized into 3 groups: The first received a CMR and CBR, the second received a CMR and CTR, and the third received a CMR alone. Measurements were performed preoperatively, intraoperatively, during the first 3 postoperative days, and after 1 and 3 months. Preoperative biometri…

Adultmedicine.medical_specialtyVisual acuityBiometrymedicine.medical_treatmentLens Capsule CrystallineCapsular tension ringIntraocular lensCataract ExtractionGroup differencesLens Implantation IntraocularOphthalmologymedicineHumansCapsulorhexisShrinkageAgedAged 80 and overPhacoemulsificationbusiness.industryPhacoemulsificationEquipment DesignProstheses and ImplantsMiddle AgedSensory SystemsSurgeryOphthalmologyCapsular bagMicroscopy Electron ScanningSurgerymedicine.symptombusinessJournal of cataract and refractive surgery
researchProduct

Contrast sensitivity after implantation of toric iris-claw lenses in phakic eyes.

2004

Abstract Purpose: To evaluate the change in contrast sensitivity after implantation of the Verisyse toric phakic intraocular lens (IOL) (AMO) for the correction of myopia with astigmatism. Setting: Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods: Eighteen eyes had implantation of an iris-supported toric phakic IOL to correct myopia with astigmatism. The mean preoperative spherical equivalent was −12.65 diopters ± 3.6 (SD). The contrast sensitivity with best spectacle correction was determined before surgery and 3 months after surgery using the CSV-1000 HGT instrument (Vector Vision Inc.). Results: Three months after IOL implantation, the mean contrast sen…

Adultmedicine.medical_specialtygenetic structuresmedia_common.quotation_subjectAstigmatismPhakic intraocular lensProsthesis DesignCycles per degreelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyLens CrystallinemedicineMyopiaContrast (vision)HumansPhakic iolIris clawDioptremedia_commonLenses Intraocularbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsLens (optics)OphthalmologySurgerysense organsbusinessJournal of cataract and refractive surgery
researchProduct