Search results for " DOSIMETRY"

showing 10 items of 120 documents

Study of the response of phenol compounds exposed to gamma photons and neutrons for Electron Spin Resonance dosimetry

2014

gamma photons neutrons organic compoundsSettore FIS/01 - Fisica SperimentaleERS dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

HOW MUCH DANGEROUS IS CT ACCORDING TO PATIENTS AND HOW DOES DOSE BILL AFFECT THEIR PERCEPTION OF IONIZING RADIATION?

2015

Aims and objectives Methods and materials Results Conclusion Personal information References

genetic structuresDosimetryEducation and trainingRadioprotection / Radiation doseRadioprotection / Radiation dose CT Education Dosimetry Education and trainingCTEducation
researchProduct

PATIENTS' KNOWLEDGE AND AWARENESS OF RADIATION DOSE AND RISKS FROM CT: DO PATIENTS NEED A PERSONALIZED COMMUNICATION OF DOSE BILL?

2015

Aims and objectives Methods and materials Results Conclusion Personal information References

genetic structuresEducation and training Education Dosimetry CT Radioprotection / Radiation doseDosimetryEducation and trainingRadioprotection / Radiation doseEducationCT
researchProduct

Combined TL and 10B-alanine ESR dosimetry for BNCT

2004

The dosimetric technique described in this paper is based on electron spin resonance (ESR) detectors using an alanine-boric compound acid enriched with 1 0 B, and beryllium oxide thermoluminescent (TL) detectors; with this combined dosimetry, it is possible to discriminate the doses due to thermal neutrons and gamma radiation in a mixed field. Irradiations were carried out inside the thermal column of a TRIGA MARK II water-pool-type research nuclear reactor, also used for Boron Neutron Capture therapy (BNCT) applications, with thermal neutron fluence from 10 9 to 10 1 4 n t h cm - 2 . The ESR dosemeters using the alanine-boron compound indicated ESR signals about 30-fold stronger than those…

inorganic chemicalsMaterials scienceBeryllium oxidechemistry.chemical_elementBoron Neutron Capture TherapyRadiationRisk AssessmentSensitivity and SpecificityThermoluminescencelaw.inventiondosimeters electron paramagnetic resonancespin resonancechemistry.chemical_compoundRadiation ProtectionIsotopeslawHumansDosimetryRadiology Nuclear Medicine and imagingBoronElectron paramagnetic resonanceBoronNeutronsRadiationRadiological and Ultrasound Technologybusiness.industryRadiotherapy Planning Computer-AssistedRadiochemistryElectron Spin Resonance SpectroscopyPublic Health Environmental and Occupational HealthReproducibility of ResultsRadiotherapy DosageGeneral MedicineSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureSystems IntegrationNeutron capturechemistryGamma RaysBody BurdenThermoluminescent DosimetryNuclear medicinebusinessRelative Biological EffectivenessRadiation Protection Dosimetry
researchProduct

EPR/ALANINE PELLETS WITH LOW Gd CONTENT FOR NEUTRON DOSIMETRY

2013

This paper reports on results obtained by electron paramagnetic resonance (EPR) measurements and Monte Carlo (MC) simulation on a blend of alanine added with low content of gadolinium oxide (5 % by weight) to improve the sensitivity to thermal neutron without excessively affecting tissue equivalence. The sensitivity is enhanced by this doping procedure of more an order of magnitude. The results are compared with those obtained with the addition of boric acid (50 % by weight) where boron is in its natural isotopic composition in order to produce low-cost EPR dosemeters. The gadolinium addition influences neutron sensitivity more than the boron addition. The presence of additives does not sub…

inorganic chemicalsMaterials scienceGadoliniumAnalytical chemistrychemistry.chemical_elementGadoliniumRadiation Dosagelaw.inventionBoric acidchemistry.chemical_compoundBoric AcidsIsotopeslawRadiology Nuclear Medicine and imagingNeutronIrradiationBoronElectron paramagnetic resonanceRadiometryNeutronsRadiationAlanineRadiological and Ultrasound Technologybusiness.industryElectron paramagnetic resonance (EPR) alanine pellet gadolinium Monte Carlo (MC) simulation dosimetryDopingtechnology industry and agriculturePublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyGeneral MedicineNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryNuclear medicinebusinessMonte Carlo Method
researchProduct

Alanine blends for ESR measurements of thermal neutron fluence in a mixed radiation field

2007

In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known…

inorganic chemicalsMaterials sciencePhotonGadoliniumAnalytical chemistrychemistry.chemical_elementRadiation DosageSensitivity and SpecificityFluencelaw.inventionRadiation ProtectionRadiation MonitoringlawMaterials TestingThermalDosimetryRadiology Nuclear Medicine and imagingNeutronESR Dosimetry BNCTElectron paramagnetic resonanceNeutronsAlanineRadiationRadiological and Ultrasound Technologybusiness.industryElectron Spin Resonance Spectroscopytechnology industry and agriculturePublic Health Environmental and Occupational HealthReproducibility of ResultsEquipment DesignGeneral MedicineNeutron temperatureEquipment Failure AnalysischemistryCalibrationbiological scienceslipids (amino acids peptides and proteins)Nuclear medicinebusinessRadiation Protection Dosimetry
researchProduct

Neutron flux and gamma dose measurement in the BNCT irradiation facility at the TRIGA reactor of the University of Pavia

2018

Abstract University of Pavia is equipped with a TRIGA Mark II research nuclear reactor, operating at a maximum steady state power of 250 kW. It has been used for many years to support Boron Neutron Capture Therapy (BNCT) research. An irradiation facility was constructed inside the thermal column of the reactor to produce a sufficient thermal neutron flux with low epithermal and fast neutron components, and low gamma dose. In this irradiation position, the liver of two patients affected by hepatic metastases from colon carcinoma were irradiated after borated drug administration. The facility is currently used for cell cultures and small animal irradiation. Measurements campaigns have been ca…

inorganic chemicalsNuclear and High Energy PhysicsMaterials science030218 nuclear medicine & medical imagingTRIGAlaw.invention03 medical and health sciencesNeutron flux measurements Neutron activation Photon dosimetry Alanine dosimetry BNCT0302 clinical medicineAlanine dosimetry; BNCT; Neutron activation; Neutron flux measurements; Photon dosimetry; Nuclear and High Energy Physics; InstrumentationlawNeutron fluxNeutronInstrumentationPhoton dosimetryDosimeterRadiochemistrySettore FIS/01 - Fisica Sperimentaletechnology industry and agricultureNuclear reactorAlanine dosimetryNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron captureNeutron flux measurements030220 oncology & carcinogenesisNeutron activationBNCTSettore MED/36 - Diagnostica Per Immagini E RadioterapiaNeutron activation
researchProduct

Study of the response of phenol compounds exposed to thermal neutrons beams for Electron Paramagnetic Resonance dosimetry

2015

Abstract This paper reports the results regarding a new organic compound (IRGANOX ® 1076 phenols) with and without low content (5% by weight) of gadolinium oxide (Gd 2 O 3 ) for Electron Paramagnetic Resonance (EPR) dosimetry of neutron beams. The dependence of EPR signal as function of neutron dose was investigated in the fluence range studied between 10 11  cm −2 to 10 14  cm −2 . We evaluated also the effect of gadolinium on 60 Co gamma photon sensitivity of this organic compound. Our analysis showed that a low concentration of gadolinium oxide (of the order of 5% of the total mass of the dosimeter) can enhance the thermal neutron sensitivity more than 10 times with a small reduction of …

inorganic chemicalsRadiationDosimeterChemistrySettore ING-IND/18 - Fisica Dei Reattori NucleariSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumRadiochemistrySettore FIS/01 - Fisica Sperimentalechemistry.chemical_elementGadoliniumFluenceNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)law.inventionElectron Paramagnetic ResonanceNCT dosimetryPhenolslawDosimetryNeutronIrradiationElectron paramagnetic resonanceInstrumentationNeutron beam
researchProduct

EPR DOSIMETRY IN A MIXED NEUTRON AND GAMMA RADIATION FIELD

2004

Suitability of Electron Paramagnetic Resonance (EPR) spectroscopy for criticality dosimetry was evaluated for tooth enamel, mannose and alanine pellets during the 'international intercomparison of criticality dosimetry techniques' at the SILENE reactor held in Valduc in June 2002, France. These three materials were irradiated in neutron and gamma-ray fields of various relative intensities and spectral distributions in order to evaluate their neutron sensitivity. The neutron response was found to be around 10% for tooth enamel, 45% for mannose and between 40 and 90% for alanine pellets according their type. According to the IAEA recommendations on the early estimate of criticality accident a…

inorganic chemicalsSafety ManagementMaterials scienceQuality Assurance Health CareRadiation DosageRisk AssessmentSensitivity and Specificitylaw.inventionRadiation Protectionstomatognathic systemlawNuclear ReactorsRisk FactorsmedicineDosimetryHumansRadiology Nuclear Medicine and imagingNeutronIrradiationElectron paramagnetic resonanceSpectroscopyRadiometryNeutronsObserver VariationRadiationRadiological and Ultrasound Technologybusiness.industryRadiochemistryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyReproducibility of ResultsGeneral MedicineReference StandardsTooth enamelEPR DOSIMETRY MIXED NEUTRON AND GAMMA RADIATION FIELDstomatognathic diseasesmedicine.anatomical_structureCriticalityGamma RaysAbsorbed doseBody BurdenFranceNuclear medicinebusinessRadioactive Hazard ReleaseRelative Biological Effectiveness
researchProduct

12C ion beam dose distribution in presence of medium inhomogeneities: comparison between different measurements and simulations with the treatment pl…

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumours localized close to organs at risk [1]. The extension of ion therapy to new clinical cases requires the exploitation of a dedicated treatment planning system (TPS) based on the existing version of TRiP98 [2,3], established TPS for carbon ions. The theoretical models and experimental databases included in TRiP98 are presently mainly based on measurements in water. This approximation can be applied successfully to reproduce many biological tissues wi…

ion therapyESR and TL dosimetry for treatment planning systemSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct