Search results for " Design"

showing 10 items of 5050 documents

Does Apico-Coronal Implant Position Influence Peri-Implant Marginal Bone Loss? A 36-Month Follow-Up Randomized Clinical Trial

2019

Purpose Preserving peri-implant bone and reducing exposure of the rough implant surface might influence long-term outcomes of implant therapy. The aim of this study was to compare peri-implant clinical and radiologic parameters after crestal and subcrestal dental implant placement at 36 months' follow-up. Materials and Methods We carried out a randomized clinical trial involving partially edentulous patients in need of an implant-supported, partial fixed dental prosthesis or a single crown. Patients were randomized according to the implant insertion depth: implants placed approximately 2 mm below the bone crest (test group) or implants placed at bone crest level (control group). They were e…

AdultMalemedicine.medical_treatmentPeriAlveolar Bone LossDentistrylaw.invention03 medical and health sciences0302 clinical medicineRandomized controlled triallawDental Prosthesis DesignHumansMedicineDental implantAgedDental Implantsbusiness.industryDental Implantation EndosseousDental prosthesis030206 dentistryMiddle AgedTreatment OutcomeDental Prosthesis DesignOtorhinolaryngology030220 oncology & carcinogenesisCoronal planeFemaleSurgeryDental Prosthesis Implant-SupportedImplantMouth EdentulousOral SurgerybusinessFollow-Up StudiesMonth follow upJournal of Oral and Maxillofacial Surgery
researchProduct

Force in the Achilles Tendon During Walking With Ankle Foot Orthosis

2009

Background Ankle foot orthoses are used for postoperative treatment of Achilles tendon ruptures and decrease calf muscle electromyography activity during walking. Hypothesis Achilles tendon load decreases with increased restriction of dorsiflexion and is associated with decreased triceps surae activity. Study Design Controlled laboratory study. Methods In 8 subjects, the maximum force and rate of force development in the Achilles tendon were measured with an optic fiber technique, and the activity of the gastrocnemius, soleus, and tibialis anterior muscles was recorded using electromyography. Trial conditions were walking barefoot and wearing an ankle-foot orthoses set in 3 different positi…

AdultMalemusculoskeletal diseasesOrthotic Devicesmedicine.medical_specialtyHeelPhysical Therapy Sports Therapy and RehabilitationWalkingElectromyographyAchilles TendonBarefootWeight-BearingYoung AdultPhysical medicine and rehabilitationAnkle/foot orthosismedicineHumansOrthopedics and Sports MedicinePostoperative PeriodFoot OrthosesRuptureAchilles tendonmedicine.diagnostic_testElectromyographyFootbusiness.industryEquipment Designmusculoskeletal systemOrthotic deviceBiomechanical Phenomenabody regionsmedicine.anatomical_structureFemaleAnkleAnklebusinesshuman activitiesThe American Journal of Sports Medicine
researchProduct

Mid- to Long-Term Outcome of Cementless Total Hip Arthroplasty in Younger Patients

2010

Purpose. To assess mid- to long-term outcomes of cementless primary total hip arthroplasty (THA) in younger patients. Methods. Records of 28 women and 34 men (75 hips) aged 18 to 55 (mean, 38) years who underwent primary THA using a hydroxyapatite-coated stem and a threaded cup and had been followed up for a mean of 10 (6–15) years were reviewed. 13 of the patients had bilateral THAs. Clinical and radiographic outcomes were evaluated. Results. After a minimum follow-up of 7 (range, 7–14) years, 12 (16%) of the hips were revised, of which 8 (11%) were for the cup. The causes for revision were late deep infections (n=2), aseptic loosening of the cup (n=4), and polyethylene wear (n=6). No stem…

AdultMalemusculoskeletal diseasesmedicine.medical_specialtyTime FactorsOsteolysisAdolescentArthroplasty Replacement Hipmedicine.medical_treatmentOsteoarthritisProsthesis DesignOsteoarthritis HipYoung Adultlcsh:Orthopedic surgerymedicineHumansRange of Motion ArticularRetrospective StudiesHip surgerybusiness.industryRetrospective cohort studyMiddle Agedmedicine.diseaseArthroplastySurgerylcsh:RD701-811Treatment OutcomeHarris Hip ScoreFemaleSurgeryHip ProsthesisbusinessRange of motionFollow-Up StudiesTotal hip arthroplastyJournal of Orthopaedic Surgery
researchProduct

Effect of bike-fit in the perception of comfort, fatigue and pain

2016

The aim of this study was to assess the influence of different bike positions on the perception of fatigue, pain and comfort. Twenty cyclists underwent three tests that involved cycling for 45 min at their individual 50% peak aerobic power output while adopting different positions on the bike. Participants performed the cycling tests adopting three positions defined by two parameters (knee flexion angle [20°, 30°, 40°] and trunk flexion angle [35°, 45°, 55°]) in random order. Angles were measured using a 2D motion analysis system during cycling and applying Fonda's correction factor. Perceptions of comfort, fatigue and pain were reported before the end of each test. The combination of 40° k…

AdultMalemusculoskeletal diseasesmedicine.medical_specialtyTrunk flexionmedia_common.quotation_subjectPosturePainPhysical Therapy Sports Therapy and RehabilitationThighSports Equipment03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationPerceptionmedicineHumansPain perceptionKnee0501 psychology and cognitive sciencesOrthopedics and Sports MedicinePower output050107 human factorsmedia_commonbusiness.industry05 social sciencesBiomechanicsTorsoEquipment Design030229 sport sciencesmusculoskeletal systemTrunkBicyclingBiomechanical Phenomenamedicine.anatomical_structureThighTime and Motion StudiesMuscle FatiguePhysical therapyPerceptionCyclingbusinesshuman activitiesJournal of Sports Sciences
researchProduct

Is a female physical empowerment campaign effective in improving positive body image, motivation for physical activity, and physical activity behavio…

2022

This Girl Can is a campaign designed to empower women to increase physical activity. The campaign uses images/videos of women of diverse body weights/shapes, ages and ethnicities being physically active, emphasizing body functionality. First, we examined the effects of multi-session (N = 3) exposures to This Girl Can on body functionality, body appreciation and self-compassion (Study 1). Second, we explored if autonomous motivation for physical activity mediated effects of This Girl Can on physical activity (Study 2). Women (Study 1: N = 186, M (SD) age = 27.55 (14.01); Study 2: N = 153, M (SD) age = 28.31 (11.70)) were randomized to This Girl Can, or control videos/images depicting idealiz…

AdultMotivationSocial PsychologyPhysical activityPositive body imageThis Girl CanTillämpad psykologiAutonomous motivationTrue experimental designVDP::Samfunnsvitenskap: 200::Psykologi: 260Body ImageHumansFemaleVDP::Medisinske Fag: 700Self-compassionExerciseGeneral PsychologyApplied Psychology
researchProduct

Inability of Laplace's law to estimate sub-bandage pressures after applying a compressive bandage: a clinical study

2021

Objective: The aim of the current study was to compare pressures exerted on the lower limb by a high compression bandage as recorded by sub-bandage sensors and those estimated by Laplace's law. The correlation between pressures obtained in each anatomical zone and the corresponding limb perimeters were explored. Method: For the measurement of sub-bandage pressures, four anatomical zones in the lower right limb were determined. Pressures were recorded by nine pneumatic sensors and a PicoPress transducer. A two-layer compression bandage system (UrgoK2, Urgo Group, France) was used for the dressing. Pressures were registered in supine position. Sensor pressures were compared with those estimat…

AdultNursing (miscellaneous)Compression BandageCompression system0206 medical engineering02 engineering and technologyLower limbClinical studyYoung Adult030207 dermatology & venereal diseases03 medical and health sciences0302 clinical medicineCompression BandagesPressureHumansMedicineLaplace transformbusiness.industryEquipment DesignModels Theoretical020601 biomedical engineeringLawCalibrationFemaleFundamentals and skillsFrancebusinessBandageJournal of Wound Care
researchProduct

Imaging photoplethysmography for clinical assessment of cutaneous microcirculation at two different depths

2016

The feasibility of bispectral imaging photoplethysmography (iPPG) system for clinical assessment of cutaneous microcirculation at two different depths is proposed. The iPPG system has been developed and evaluated for in vivo conditions during various tests: (1) topical application of vasodilatory liniment on the skin, (2) skin local heating, (3) arterial occlusion, and (4) regional anesthesia. The device has been validated by the measurements of a laser Doppler imager (LDI) as a reference. The hardware comprises four bispectral light sources (530 and 810 nm) for uniform illumination of skin, video camera, and the control unit for triggering of the system. The PPG signals were calculated and…

AdultPathologymedicine.medical_specialtyAdolescentBiomedical EngineeringLinimentHyperemiaCutaneous microcirculation02 engineering and technologyAdministration Cutaneous01 natural sciencesMicrocirculation010309 opticsBiomaterialsYoung AdultPhotoplethysmogram0103 physical sciencesImage Processing Computer-AssistedHumansMedicinePhotoplethysmographySkinbusiness.industryMicrocirculationEquipment DesignLaser Doppler velocimetryHand021001 nanoscience & nanotechnologyArterial occlusionAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials0210 nano-technologybusinessPerfusionPreclinical imagingAnesthesia LocalBiomedical engineeringJournal of Biomedical Optics
researchProduct

Influence of optic quality on contrast sensitivity and visual acuity in eyes with a rigid or flexible phakic intraocular lens

2009

Purpose To determine whether the difference in optic quality between 2 types of phakic intraocular lenses (pIOLs) affects visual quality. Setting Fundacion Oftalmologica del Mediterraneo, Valencia, Spain. Methods Before implantation of a pIOL for myopia, all eyes had an examination including corrected (CDVA) and uncorrected (UDVA) distance visual acuity testing, corneal endothelial cell count (ECC), and intraocular pressure (IOP) measurement. The postoperative outcomes, determined at least 1 year after surgery, were CDVA; UDVA; contrast sensitivity function under photopic, mesopic, and mesopic with glare conditions; ECC; IOP; keratometry (Scheimpflug photography); and total ocular aberratio…

AdultPhakic Intraocular LensesIntraocular pressuremedicine.medical_specialtyVisual acuityOptical Phenomenagenetic structuresAnterior ChamberMesopic visionmedicine.medical_treatmentmedia_common.quotation_subjectVisual AcuityCell CountIntraocular lensProsthesis DesignPhakic intraocular lensGlarelaw.inventionContrast SensitivityLens Implantation IntraocularlawOphthalmologyMyopiamedicineHumansContrast (vision)Intraocular Pressuremedia_commonKeratometerbusiness.industryEndothelium Cornealeye diseasesSensory SystemsOphthalmologyOptometrySurgerysense organsmedicine.symptombusinessPhotopic visionJournal of Cataract and Refractive Surgery
researchProduct

Peri‐implant marginal bone loss reduction with platform‐switching components: 5‐Year post‐loading results of an equivalence randomized clinical trial

2019

Abstract Aim To compare the clinical performance and marginal bone levels of implants restored with platform‐switching (PS) or platform‐matching (PM) abutments. Materials and Methods Adult patients missing two or more adjacent teeth in the posterior mandible received 2–4 CAMLOG SCREW‐LINE implants and were randomly allocated to the PM or PS group, receiving the corresponding prosthetic components from surgery onwards. Implants were conventionally loaded with single cemented crowns. Patients were followed annually for 5 years. Outcome measures were marginal bone level changes, implant survival, performance of the prosthetic components and clinical parameters plaque index, sulcus bleeding ind…

AdultPlaque indeximplantPlatform switchingPeriAlveolar Bone LossDentistryMandiblelaw.inventioncrestal bone preservation03 medical and health sciences0302 clinical medicineRandomized controlled triallawMedicineHumans030212 general & internal medicinestandardized radiographBone levelSurvival rateImplant DentistryCrownsbusiness.industryplatform switchingDental Implantation EndosseousDental Plaque IndexClinical performancebone levelDental Implant-Abutment Design030206 dentistryrandomized clinical trialTreatment Outcomeimplant successplatform matchPeriodonticsImplantDental Prosthesis Implant-SupportedbusinessImplant TherapyFollow-Up StudiesJournal of Clinical Periodontology
researchProduct

Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…

2010

Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…

AdultPulse repetition frequencyLinguistics and Languagemedicine.medical_specialtySpeech perceptionAdolescentHearing Loss SensorineuralLoudness Perceptionmedicine.medical_treatmentmedia_common.quotation_subjectAudiologyProsthesis DesignAffect (psychology)Severity of Illness IndexLanguage and LinguisticsCochlear nucleusLoudnessYoung AdultSpeech and HearingProsthesis FittingCochlear implantPerceptionmedicineHumansCorrection of Hearing ImpairmentHabituationAgedmedia_commonAged 80 and overAuditory ThresholdSignal Processing Computer-AssistedMiddle AgedElectric StimulationEuropeCochlear ImplantsPersons With Hearing ImpairmentsAcoustic StimulationAuditory PerceptionSpeech PerceptionAudiometry SpeechPsychologyInternational Journal of Audiology
researchProduct