Search results for " Detector"
showing 10 items of 2719 documents
Search for anomalous production of events with two photons and additional energetic objects at CDF
2010
27 páginas, 17 figuras, 5 tablas.-- CDF Collaboration: et al.
Measurement of the lifetime of tau-lepton
1996
The tau lepton lifetime is measured with the L3 detector at LEP using the complete data taken at centre-of-mass energies around the Z pole resulting in tau_tau = 293.2 +/- 2.0 (stat) +/- 1.5 (syst) fs. The comparison of this result with the muon lifetime supports lepton universality of the weak charged current at the level of six per mille. Assuming lepton universality, the value of the strong coupling constant, alpha_s is found to be alpha_s(m_tau^2) = 0.319 +/- 0.015(exp.) +/- 0.014 (theory). The tau lepton lifetime is measured with the L3 detector at LEP using the complete data taken at centre-of-mass energies around the Z pole resulting in τ τ =293.2 ± 2.0 (stat) ± 1.5 (syst) fs . The c…
Measurement of the muon neutrino inclusive charged-current cross section in the energy range of 1–3 GeV with the T2K INGRID detector
2016
International audience; We report a measurement of the $\nu_{\mu}$-nucleus inclusive charged current cross section (=$\sigma^{cc}$) on iron using data from exposed to the J-PARC neutrino beam. The detector consists of 14 modules in total, which are spread over a range of off-axis angles from 0$^\circ$ to 1.1$^\circ$. The variation in the neutrino energy spectrum as a function of the off-axis angle, combined with event topology information, is used to calculate this cross section as a function of neutrino energy. The cross section is measured to be $\sigma^{cc}(1.1\text{ GeV}) = 1.10 \pm 0.15$ $(10^{-38}\text{cm}^2/\text{nucleon})$, $\sigma^{cc}(2.0\text{ GeV}) = 2.07 \pm 0.27$ $(10^{-38}\te…
Search for CP violation using T-odd correlations in D-0 -> K+K-pi(+)pi(-) decays
2014
A search for $CP$ violation using $T$-odd correlations is performed using the four-body $D^0 \to K^+K^-\pi^+\pi^-$ decay, selected from semileptonic $B$ decays. The data sample corresponds to integrated luminosities of $1.0\,\text{fb}^{-1}$ and $2.0\,\text{fb}^{-1}$ recorded at the centre-of-mass energies of 7 TeV and 8 TeV, respectively. The $CP$-violating asymmetry $a_{CP}^{T\text{-odd}}$ is measured to be $(0.18\pm 0.29\text{(stat)}\pm 0.04\text{(syst)})\%$. Searches for $CP$ violation in different regions of phase space of the four-body decay, and as a function of the $D^0$ decay time, are also presented. No significant deviation from the $CP$ conservation hypothesis is found.
Stability of charge-pump phase-locked loops : the hold-in and pull-in ranges
2020
The problem of design and analysis of synchronization control circuits is a challenging task for many applications: satellite navigation, digital communication, wireless networks, and others. In this article the Charge-Pump Phase-Locked Loop (CP-PLL) electronic circuit, which is used for frequency synthesis and clock generation in computer architectures, is studied. Analysis of CP-PLL is not trivial: full mathematical model, rigorous definitions, and analysis still remain open issues in many respects. This article is devoted to development of a mathematical model, taking into account engineering aspects of the circuit, interpretation of core engineering problems, definition in relation to m…
HARD X-RAY CZT DETECTOR DEVELOPMENT AND TESTING ON STRATOSPHERIC BALLOON PAYLOADS
2009
We report on the R&D activities on the development of room temperature semiconductor detectors (CZT detectors) for high energy space instrumentation. Our groups have been involved in the development of new hard X and soft gamma ray telescopes (e.g. Laue lens telescopes) and focal plane detectors. We present the characteristics and the performance of various CZT detector prototypes coupled with custom read-out electronics. The main target of this R&D activity is an end to end system for domestic growth CZT crystals, new sensor configurations and related read out architecture to provide an effective 3D focal plane able to perform contemporaneously imaging (spatial resolution mm or better), ti…
Advances in High-Energy-Resolution CdZnTe Linear Array Pixel Detectors with Fast and Low Noise Readout Electronics
2023
Radiation detectors based on Cadmium Zinc Telluride (CZT) compounds are becoming popular solutions thanks to their high detection efficiency, room temperature operation, and to their reliability in compact detection systems for medical, astrophysical, or industrial applications. However, despite a huge effort to improve the technological process, CZT detectors’ full potential has not been completely exploited when both high spatial and energy resolution are required by the application, especially at low energies (<10 keV), limiting their application in energy-resolved photon counting (ERPC) systems. This gap can also be attributed to the lack of dedicated front-end electronics whic…
A chamber to test the response of radon detectors to changing environmental conditions.
2011
Radon risk assessment is carried out with accurate measurements with active or passive instrumentation. All radon detectors must be calibrated and tested using a radon chamber containing a known concentration of radon produced by specific sources of 226Ra. Some of the chambers can also be used to test the response of detectors as a function of environmental conditions. In this case, it can be inferred a calibration curve with respect to changing of the parameter considered. For this aim, a new chamber radon was designed and realized to perform both calibration of instruments and to study the detector response in a large range of variation of the environmental parameters (pressure, 700 - 110…
ATLAS beam test results
1996
Many different configurations of electronics and-semiconductor strip detectors were studied in 1995 using the ATLAS tracking detector test area at the H8 beam-line of the CERN SPS. A significant fraction of these investigations are presented elsewhere in this volume and this paper will concentrate on the results with silicon strip detectors read out with electronics preserving the pulse height information. Data has been collected with the ADAM, APV5 and FElix read-out chips on a number of different detectors. The first results are presented for read out with LHC electronics of detectors to the ATLAS-A specification of 112.5 mu m pitch, employing n-strips in n-type silicon, capacitive coupli…
Experimental results from Al/p-CdTe/Pt X-ray detectors
2013
Recently, Al/CdTe/Pt detectors have been proposed for the development of high resolution X-ray spectrometers. Due to the low leakage currents, these detectors allow high electric fields and the pixellization of anodes with the possibility to realize single charge carrier sensing detectors. In this work, we report on the results of electrical and spectroscopic investigations on CdTe diode detectors with Al/CdTe/Pt electrode configuration (4.1×4.1×0.75 and 4.1×4.1×2 mm3). The detectors are characterized by very low leakage currents in the reverse bias operation: 0.3 nA at 25 °C and 2.4 pA at -25 °C under a bias voltage of -1000 V. The spectroscopic performance of the detectors at both low and…