Search results for " Detectors"
showing 10 items of 2027 documents
Magnetic field uniformity in neutron electric dipole moment experiments
2019
© 2019 American Physical Society. Magnetic-field uniformity is of the utmost importance in experiments to measure the electric dipole moment of the neutron. A general parametrization of the magnetic field in terms of harmonic polynomial modes is proposed, going beyond the linear-gradients approximation. We review the main undesirable effects of nonuniformities: depolarization of ultracold neutrons and Larmor frequency shifts of neutrons and mercury atoms. The theoretical predictions for these effects were verified by dedicated measurements with the single-chamber neutron electric-dipole-moment apparatus installed at the Paul Scherrer Institute. ispartof: Physical Review A vol:99 issue:4 sta…
Technical Design Report for the Paul Scherrer Institute Experiment R-12-01.1: Studying the Proton "Radius" Puzzle with $\mu p$ Elastic Scattering
2017
The difference in proton radii measured with $\mu p$ atoms and with $ep$ atoms and scattering remains an unexplained puzzle. The PSI MUSE proposal is to measure $\mu p$ and $e p$ scattering in the same experiment at the same time. The experiment will determine cross sections, two-photon effects, form factors, and radii independently for the two reactions, and will allow $\mu p$ and $ep$ results to be compared with reduced systematic uncertainties. These data should provide the best test of lepton universality in a scattering experiment to date, about an order of magnitude improvement over previous tests. Measuring scattering with both particle polarities will allow a test of two-photon exch…
Energy of the $^{229}$Th nuclear clock transition
2019
The first nuclear excited state of $^{229}$Th offers the unique opportunity for laser-based optical control of a nucleus. Its exceptional properties allow for the development of a nuclear optical clock which offers a complementary technology and is expected to outperform current electronic-shell based atomic clocks. The development of a nuclear clock was so far impeded by an imprecise knowledge of the energy of the $^{229}$Th nuclear excited state. In this letter we report a direct excitation energy measurement of this elusive state and constrain this to 8.28$\pm$0.17 eV. The energy is determined by spectroscopy of the internal conversion electrons emitted in-flight during the decay of the …
Detekcia vektora spinovej polarizácie vo viackanálovej spinovo rozlýšenej fotoemissie za použitia spinového filtra založeného na Ir(001)
2016
Physical review / B 95(10), 104423 (2017). doi:10.1103/PhysRevB.95.104423
Enhanced effects of variation of the fundamental constants in laser interferometers and application to dark matter detection
2015
We outline new laser interferometer measurements to search for variation of the electromagnetic fine-structure constant $\alpha$ and particle masses (including a non-zero photon mass). We propose a strontium optical lattice clock -- silicon single-crystal cavity interferometer as a novel small-scale platform for these new measurements. Multiple passages of a light beam inside an interferometer enhance the effects due to variation of the fundamental constants by the mean number of passages ($N_{\textrm{eff}} \sim 10^2$ for a large-scale gravitational-wave detector, such as LIGO, Virgo, GEO600 or TAMA300, while $N_{\textrm{eff}} \sim 10^5$ for a strontium clock -- silicon cavity interferomete…
Miniature Cavity-Enhanced Diamond Magnetometer
2017
We present a highly sensitive miniaturized cavity-enhanced room-temperature magnetic-field sensor based on nitrogen-vacancy (NV) centers in diamond. The magnetic resonance signal is detected by probing absorption on the 1042\,nm spin-singlet transition. To improve the absorptive signal the diamond is placed in an optical resonator. The device has a magnetic-field sensitivity of 28 pT/$\sqrt{\rm{Hz}}$, a projected photon shot-noise-limited sensitivity of 22 pT/$\sqrt{\rm{Hz}}$ and an estimated quantum projection-noise-limited sensitivity of 0.43 pT/$\sqrt{\rm{Hz}}$ with the sensing volume of $\sim$ 390 $\mu$m $\times$ 4500 $\mu$m$^{2}$. The presented miniaturized device is the basis for an e…
Photonuclear reactions with zinc: A case for clinical linacs
2015
WOS: 000365732300003
Potential for a precision measurement of solar pp neutrinos in the Serappis experiment
2022
The European physical journal / C 82(9), 779 (2022). doi:10.1140/epjc/s10052-022-10725-y
Quantum sensitivity limits of nuclear magnetic resonance experiments searching for new fundamental physics
2021
Nuclear magnetic resonance is a promising experimental approach to search for ultra-light axion-like dark matter. Searches such as the cosmic axion spin-precession experiments (CASPEr) are ultimately limited by quantum-mechanical noise sources, in particular, spin-projection noise. We discuss how such fundamental limits can potentially be reached. We consider a circuit model of a magnetic resonance experiment and quantify three noise sources: spin-projection noise, thermal noise, and amplifier noise. Calculation of the total noise spectrum takes into account the modification of the circuit impedance by the presence of nuclear spins, as well as the circuit back-action on the spin ensemble. S…
The ATLAS Inner Detector commissioning and calibration
2010
The ATLAS Inner Detector is a composite tracking system consisting of silicon pixels, silicon strips and straw tubes in a 2 T magnetic field. Its installation was completed in August 2008 and the detector took part in data-taking with single LHC beams and cosmic rays. The initial detector operation, hardware commissioning and insitu calibrations are described. Tracking performance has been measured with 7.6 million cosmic-ray events, collected using a tracking trigger and reconstructed with modular pattern-recognition and fitting software. The intrinsic hit efficiency and tracking trigger efficiencies are close to 100%. Lorentz angle measurements for both electrons and holes, specific energ…