Physiological responses and parasympathetic reactivation in rescue interventions: The effect of the breathing apparatus.
2018
This study aimed to assess the effect of wearing a breathing apparatus during a simulated rescue intervention on psychophysiological responses and parasympathetic reactivation of firefighters. Thirty-four firefighters participated in this study which consisted of four experimental sessions conducted randomly: a maximal fitness test and three rescue interventions performed (a) with personal protective clothing (PPC); (b) with PPC and the full self-contained breathing apparatus (SCBA), including cylinder, full-face piece, and breathing regulator; and (c) with PPC and only the cylinder of the self-contained breathing apparatus (SCBAc). Physiological (heart rate [HR], breathing frequency [BF]) …
Atraumatic maxillary sinus elevation using threaded bone dilators for immediate implants. A three-year clinical study.
2008
Objective: The aim of this study was to evaluate the efficacy of sinus floor elevation using sequential bone dilators. Materials and Methods: Thirty patients took part in the study (18 women and 12 men) with ages ranging between thirty-six and sixty-three years, selected according to inclusion and exclusion criteria, who showed a bone deficit in the upper posterior alveolar margin of 5-8 mm in height. Sixty expanded platform internal connection implants were placed with diameters of 4/5/4 mm and lengths varying between 10 (n=10) and 11.5 mm (n= 50). Results: Data obtained were analyzed using SPSS 15.0 software. The average intra-sinus bone gain with MP3 biomaterial of porcine origin was 4.1…
Plaque removal efficacy of power and manual toothbrushes: a comparative study
2009
The aim of this study was to compare the plaque removal efficacy of a new oscillating/rotating/pulsating toothbrush [Oral-B® Professional Care® 8500 (PC 8500)] with two manual toothbrushes [Oral-B® CrossAction™ Vitalizer (CAV) and Oral-B® Indicator™ (IND), respectively]. The safety of the PC 8500 was also assessed. The study was a single-use, observer-masked, randomised 3×3 Latin square crossover design balanced for carryover effects. The enrolled subjects (n=66) refrained from brushing for 23–25 h before each clinical examination. Plaque scores were recorded before and after brushing with the allocated toothbrush using the Turesky et al. modification of the Quigley and Hein plaque index. T…
Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist
2019
Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…
Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad
2015
[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…
Operative Treatment of Scoliosis With Cotrel-Dubousset-Hopf Instrumentation
1997
Study design This study analyzes the effects of a new anterior spinal instrumentation system and the results of use in 50 patients with scoliosis. Objectives Anterior spine systems are reviewed. The principles of a new anterior spinal instrumentation system allowing for postoperative care without external support are discussed. Summary of background data Numerous different implants have been presented in the literature for anterior spinal surgery. Nevertheless a primary stable anterior instrumentation was not available for multisegmental procedures until now, and the restoration of lordosis in the lumbar spine was very difficult with the common devices. The development of more stable device…
Increased gait variability during robot-assisted walking is accompanied by increased sensorimotor brain activity in healthy people
2019
Abstract Background Gait disorders are major symptoms of neurological diseases affecting the quality of life. Interventions that restore walking and allow patients to maintain safe and independent mobility are essential. Robot-assisted gait training (RAGT) proved to be a promising treatment for restoring and improving the ability to walk. Due to heterogenuous study designs and fragmentary knowlegde about the neural correlates associated with RAGT and the relation to motor recovery, guidelines for an individually optimized therapy can hardly be derived. To optimize robotic rehabilitation, it is crucial to understand how robotic assistance affect locomotor control and its underlying brain act…
The effects of a roundtrip trans-American jet travel on physiological stress, neuromuscular performance, and recovery.
2016
The purpose was to examine the effects of a round trip trans-American jet travel on performance, hormonal alterations, and recovery. Ten matched pairs of recreationally trained men were randomized to either a compression group (COMP) ( n = 10; age: 23.1 ± 2.4 yr; height: 174.8 ± 5.3 cm; body mass: 84.9 ± 10.16 kg; body fat: 15.3 ± 6.0%) or control group (CONT) ( n = 9; age: 23.2 ± 2.3 yr; height: 177.5 ± 6.3 cm; weight: 84.3 ± 8.99 kg; body fat: 15.1 ± 6.4%). Subjects flew directly from Hartford, CT to Los Angeles, CA 1 day before a simulated sport competition (SSC) designed to create muscle damage and returned the next morning on an overnight flight back home. Both groups demonstrated jet…
Effect of probe contact pressure on the photoplethysmographic assessment of conduit artery stiffness
2013
Currently, photoplethysmography (PPG) is a frequently studied optical blood pulsation detection tech- nique among biophotonic and biomedical researchers due to the fact that it shows high potential for estimating the arterial stiffness (AS). The extraction of diagnostically useful information requires standardized measurement pro- cedure with good repeatability. However, the effects of a crucially important factor—the optimal contact pressure (CP) of the probe—are often ignored. Also, CP values are not reported to evaluate those effects. It is hypothesized that AS estimated from PPG pulse wave 2nd derivative parameter b∕a is strongly inconsistent when recorded at nonoptimal probe CP. Our pi…
Resource utilization and productivity loss in persons with spina bifida—an observational study of patients in a tertiary urology clinic in Germany.
2014
Background and purpose To investigate resource use and burden associated with spina bifida (SB) in Germany. Methods A questionnaire was used to obtain information on SB-related healthcare resource use and assistive technologies used for the last 1 and 10 years. Individuals with SB were recruited at a tertiary specialist clinic. To participate, persons with SB required the cognitive ability to respond or a caregiver to answer questions on their behalf. They could use personal medical charts or other records to answer. The analyses included assessment of frequency and extent of resource use for both time frames. Results Data on 88 persons with a diagnosis of SB were collected (44% female). Du…