Modelling glow curves of thermoluminescent radiometric devices

2017

Thermoluminescent (TLD) radiation dosimeters enjoy wide usage due to low cost and simplicity of use. They however require complex device modelling in order to extract the measured dose. A new glow peak model and fit method are presented, that offer a more robust fit to the glow-curves and allows operators to enter visually inspectable parameters (rather than physical quantities difficult to estimate from the visual inspection of the glow curves themselves). Fits performed on the GLOCANIN-challenge's RefGlow-002 and RefGlow-009 [2] are presented, highlighting the good performance of the GEMINI C++ code written.

Read-only memoryOpticsDosimeterbusiness.industryComputer sciencelawElectronic packagingThermoluminescent dosimeterIntegrated circuitbusinessThermoluminescencePhysical quantitylaw.invention2017 IEEE 23rd International Symposium for Design and Technology in Electronic Packaging (SIITME)
researchProduct

Characterisation of two new radiochromic gel dosimeters TruView™ and ClearView™ in combination with the vista™ optical CT scanner: A feasibility study

2018

This study aims at characterising the properties of TruView™ and ClearView™ two new gel dosimeters (Modus Medical Devices Inc.) and at studying the feasibility of relative dosimetry using these dosimeters and the Vista™ Optical CT scanner to accurately evaluate dose.In this work, we investigated key dosimetric aspects (dose response, energy and dose rate dependence) and stability of these radiochromic gels initiated in preliminary works (Huet et al., 2017; Colnot et al., 2017) using spectrophotometric measurements. Moreover, by mean of optical CT scanning (Vista™), their performances to measure relative depth dose (PDD) and cross profiles were analysed.TruView™ and ClearView™ present a line…

ScannerTomography Scanners X-Ray ComputedMaterials scienceBiophysicsGeneral Physics and AstronomyElectrons[SDV.CAN]Life Sciences [q-bio]/Cancer[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOptical ctRelative depthDosimetryRadiology Nuclear Medicine and imagingPhoton beamRadiometryComputingMilieux_MISCELLANEOUSPhotonsDosimeterPhantoms ImagingRadiation DosimetersStray lightOptical ImagingUncertaintyGeneral MedicineSpectrophotometry030220 oncology & carcinogenesisCalibrationFeasibility StudiesTomography X-Ray ComputedDose rateBiomedical engineering
researchProduct

Phenol compounds as new materials for Electron Paramagnetic Resonance dosimetry in clinical photon and electron beams,

2016

In the last decades several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Paramagnetic Resonance (EPR) dosimetry to radiotherapy with different types of radiation beams. EPR is a spectroscopic method for investigating the structure and dynamics of such paramagnetic species. Free radicals are known to be produced when a compound is irradiated with ionizing radiations. The concentration of radiation-induced free radicals is proportional to the energy released inside in the medium and this allows for dosimetric measurements through EPR technique. The use of alanine as a dosimetric material gave the possibility to apply EPR spectroscopy…

Settore FIS/01 - Fisica SperimentaleESR EPR Solid State Dosimeters Clinical Beams New MaterialsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Correction factors for ionization chamber measurements with the ‘Valencia’ and ‘large field Valencia’ brachytherapy applicators

2018

Treatment of small skin lesions using HDR brachytherapy applicators is a widely used technique. The shielded applicators currently available in clinical practice are based on a tungsten-alloy cup that collimates the source-emitted radiation into a small region, hence protecting nearby tissues. The goal of this manuscript is to evaluate the correction factors required for dose measurements with a plane-parallel ionization chamber typically used in clinical brachytherapy for the 'Valencia' and 'large field Valencia' shielded applicators. Monte Carlo simulations have been performed using the PENELOPE-2014 system to determine the absorbed dose deposited in a water phantom and in the chamber act…

Skin Neoplasmsmedicine.medical_treatmentBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyDose profileRadiationImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsmedicineRadiology Nuclear Medicine and imagingRadiometryValenciaPhysicsRadiological and Ultrasound TechnologybiologyPhantoms ImagingRadiation Dosimetersbusiness.industryRadiotherapy Dosagebiology.organism_classification030220 oncology & carcinogenesisAbsorbed doseIonization chamberbusinessMonte Carlo MethodPhysics in Medicine & Biology
researchProduct

Study of optical absorbance and MR relaxation of Fricke xylenol orange gel dosimeters

2017

Abstract Studies on the optical absorbance spectra of Fricke xylenol orange gel dosimeters were performed, in the wavelength range from 300 nm to 800 nm, in order to highlight some particular characteristics that can affect the achievable precision. The spectra are different mainly due to the different types of xylenol orange that was used and to a lower extent due to the different gelling agents (agarose or gelatine). The characteristic of variation of absorbance spectra versus dose, however, are similar in the various cases and can explain some peculiarities, as apparent effects of dose threshold. Changes of spectral shapes appear over the time after irradiation. Magnetic resonance measur…

Xylenol orangeSettore ING-IND/20 - Misure E Strumentazione NucleariAnalytical chemistry01 natural sciencesSpectral line030218 nuclear medicine & medical imagingIon03 medical and health scienceschemistry.chemical_compound0302 clinical medicineFricke gel dosimeter; MR measurement; Optical absorbance spectra; Radiation; Instrumentation0103 physical sciencesmedicineIrradiationFricke gel dosimeterInstrumentationSettore CHIM/02 - Chimica FisicaRadiationDosimeter010308 nuclear & particles physicsSettore FIS/01 - Fisica SperimentaleRelaxation (NMR)MR measurementSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryFerricAgarosesense organsOptical absorbance spectramedicine.drugRadiation Measurements
researchProduct

Characterization of alanine EPR detectors response in clinical carbon ion beams

2012

Heavy-ions beams offer several advantages compared to other radiation such as low lateral scattering and high biological effectiveness (RBE) in the Bragg peak region, making them particularly attractive for the treatment of radio-resistant tumors localized close to organs at risk [1]. Although ion beam radiotherapy ultimately requires dose prescription in terms of biological dose or cell survival, absorbed dose is still the quantity mostly used in clinical quality assurance and to dosimetrically characterize the beam. Moreover, the nuclear projectile fragmentation of heavy ions because of inelastic nuclear interactions with medium produces secondary particles with lower Z. The detailed know…

alanine EPR dosimeterscarbon ion beamsSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)
researchProduct

Implementation of dosimetry equipment and phantoms at the MedAustron light ion beam therapy facility

2017

Purpose: To describe the implementation of dosimetry equipment and phantoms into clinical practice of light ion beam therapy facilities. This work covers standard dosimetry equipment such as computerized water scanners, films, 2D-array, thimble and plane parallel ionization chambers, but also dosimetry equipment specifically devoted to the pencil beam scanning delivery technique such as water columns, scintillating screens or multi-layer ionization chambers. Method: Advanced acceptance testing procedures developed at MedAustron and complementary to the standard acceptance procedures proposed by the manufacturer are presented. Detailed commissioning plans have been implemented for each piece…

medicine.medical_specialtyIon beamComputer scienceNuclear engineeringmedicine.medical_treatmentImaging phantomPelvis030218 nuclear medicine & medical imagingMedical physicist03 medical and health sciences0302 clinical medicinemedicineHumansDosimetryMedical physicsRadiometryPencil-beam scanningIonsPhantoms ImagingRadiation DosimetersUncertaintyGeneral MedicinePencil (optics)Radiation therapy030220 oncology & carcinogenesisSoftwareMedical Physics
researchProduct

A Monte Carlo-aided design of a modular 241Am-Be neutron irradiator

2013

Monte Carlo studies aimed at designing a modular 241Am-Be neutron irradiator for testing neutron detectors and personal dosimeters and processing large volume samples are reported in this study. The evaluation of the shapes and thicknesses of the moderator and shielding materials was carried out by a MCNP5 Monte Carlo simulation code. The reliability of the simulation was experimentally verified by the activation of gold foils and TLD dosimeter measurements in an irradiation cell placed at the center of the test configuration.

medicine.medical_specialtySettore ING-IND/20 - Misure E Strumentazione NucleariPhysics::Instrumentation and DetectorsNuclear engineeringMonte Carlo methodPhysics::Medical PhysicsReliability (semiconductor)medicineNeutron detectionNeutronMedical physicslcsh:Nuclear and particle physics. Atomic energy. RadioactivitySafety Risk Reliability and Quality241Am-Be sourcePhysicsDosimeterbusiness.industryModular designMonte Carlo methodNuclear Energy and Engineeringneutron irradiator 241Am-Be source Monte Carlo methodElectromagnetic shieldingneutron irradiatorlcsh:QC770-798Thermoluminescent dosimeterbusinessNuclear Technology and Radiation Protection
researchProduct

Radioluminescence Response of Ce-, Cu-, and Gd-Doped Silica Glasses for Dosimetry of Pulsed Electron Beams

2021

Radiation-induced emission of doped sol-gel silica glass samples was investigated under a pulsed 20-MeV electron beam. The studied samples were drawn rods doped with cerium, copper, or gadolinium ions, which were connected to multimode pure-silica core fibers to transport the induced luminescence from the irradiation area to a signal readout system. The luminescence pulses in the samples induced by the electron bunches were studied as a function of deposited dose per electron bunch. All the investigated samples were found to have a linear response in terms of luminescence as a function of electron bunch sizes between 10−5 Gy/bunch and 1.5×10−2 Gy/bunch. The presented results show that these…

optical fiberLuminescenceMaterials scienceradiation-induced luminescenceAnalytical chemistryElectronsTP1-118502 engineering and technologyElectronhiukkaskiihdyttimetelektronit01 natural sciencesBiochemistryArticleAnalytical Chemistrylaw.inventionmittauslaitteetlaw0103 physical sciencesDosimetrydosimetritIrradiationElectrical and Electronic EngineeringRadiometryInstrumentation[PHYS]Physics [physics]optiset kuidutdosimetry010308 nuclear & particles physicsChemical technologypulsed electron beamluminesenssiDopingParticle acceleratorRadioluminescenceSilicon Dioxide021001 nanoscience & nanotechnologyelectron acceleratorAtomic and Molecular Physics and Opticspoint dosimeterCondensed Matter::Soft Condensed MattersäteilyfysiikkaCathode rayPhysics::Accelerator Physics0210 nano-technologyLuminescence
researchProduct

Properties of Gd-Doped Sol-Gel Silica Glass Radioluminescence under Electron Beams

2022

International audience; The radiation-induced emission (RIE) of Gd3+-doped sol–gel silica glass has been shown to have suitable properties for use in the dosimetry of beams of ionizing radiation in applications such as radiotherapy. Linear electron accelerators are commonly used as clinical radiotherapy beams, and in this paper, the RIE properties were investigated under electron irradiation. A monochromator setup was used to investigate the light properties in selected narrow wavelength regions, and a spectrometer setup was used to measure the optical emission spectra in various test configurations. The RIE output as a function of depth in acrylic was measured and compared with a reference…

optiset kuidut[PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]optical fiberLuminescencedosimetryradiation-induced luminescencepulsed electron beamluminesenssiElectronsvaimennuselectron acceleratorBiochemistryAtomic and Molecular Physics and Opticspoint dosimeterAnalytical Chemistrydosimetry; electron accelerator; optical fiber; point dosimeter; pulsed electron beam; radiation-induced attenuation; radiation-induced luminescenceradiation-induced attenuationdosimetritGlassElectrical and Electronic EngineeringParticle AcceleratorsRadiometryInstrumentation