Search results for " Echocardiography"
showing 10 items of 147 documents
Role of cardiac computed tomography in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic…
2016
OBJECTIVE The aim of our study was to evaluate the diagnostic performance of cardiac computed tomography (CCT) in the evaluation of coronary artery stenosis in patients with ascending aorta aneurysm detected at transthoracic echocardiography. METHODS We conducted a retrospective analysis of patients with an aneurysm 45 mm or greater at transthoracic echocardiography who underwent CCT from 2012 to 2014 in our hospital. We calculated the sensitivity, specificity, and positive and negative predictive values of CCT for the assessment of coronary artery stenosis (<50% or ≥50% stenosis) in patients who underwent conventional coronary angiography. RESULTS We included 104 patients (73 men, aged 64 …
Right ventricular diameter predicts all-cause mortality in heart failure with preserved ejection fraction.
2019
Left ventricular ejection fraction (EF) is helpful to differentiate heart failure (HF) phenotype in clinical practice. The aim of the study was to identify simple echocardiographic predictors of post-discharge all-cause mortality in hospitalized HF patients. Patients with acute HF (75 ± 9.8 years), classified in preserved (≥ 50%) and reduced (< 50%) EF (HFpEF and HFrEF, respectively), were enrolled. The mean follow-up period was of 25.4 months. Patients definitively analyzed were 135. At multivariate Cox model, right ventricular diameter (RVd), inferior vena cava diameter (IVCd) and blood urea nitrogen (BUN) resulted to be significantly associated with all-cause mortality in HFpEF (HR 2.…
Perforated giant mycotic aneurysm of mitral valve in a drug-addicted young man: Rare complication of infective endocarditis
2017
Infective endocarditis (IE) affects patients at high clinical risk and may present as an acute and rapidly progressive, subacute or chronic infection. Transthoracic and transesophageal echocardiography represent the key diagnostic method in IE diagnosis. In particular, three-dimensional transesophageal echocardiography represents the imaging technique that allows to establish with adequate accuracy dimensions, shape, and localization of endocarditis vegetations. In our case, we show a huge vermiform mycotic aneurysm in an immunodeficient young drug-addicted man with severe mitral valve regurgitation and the additive value of three-dimensional transesophageal echocardiography in this specifi…
Cardiac involvement in rheumatoid arthritis: Evidence of silent heart disease
1995
Background : Rlieumatoid arthritis (RA) is a systemic disease involving many organ systems and is frequently accompanied by cardiac alterations. However, there is considerable disagreement concerning the cardiac abnormalities found in patients with RA. The purpose of our investigation was to determine, by a non-invasive method such as echocardiography, the nature and extent of cardiac involvement in RA patients with no symptoms of cardiac disease, in comparison with a control sample. Methods : We selected 35 patients affected by rheumatoid arthritis (five men, 30 women), aged 51 ± 11 years. No patient had either symptoms of cardiac disease or extra cardiac complaint. As a control group we s…
Echocardiographic reference ranges for normal non-invasive myocardial work indices: results from the EACVI NORRE study
2019
International audience; Aims - To obtain the normal ranges for 2D echocardiographic (2DE) indices of myocardial work (MW) from a large group of healthy volunteers over a wide range of ages and gender. Methods and results - A total of 226 (85 men, mean age: 45 ± 13 years) healthy subjects were enrolled at 22 collaborating institutions of the Normal Reference Ranges for Echocardiography (NORRE) study. Global work index (GWI), global constructive work (GCW), global work waste (GWW), and global work efficiency (GWE) were estimated from left ventricle (LV) pressure-strain loops. Peak LV systolic pressure was non-invasively derived from brachial artery cuff pressure. The lowest values of MW indic…
Analysis of left ventricular volumes and function: a multicenter comparison of cardiac magnetic resonance imaging, cine ventriculography, and unenhan…
2013
Background: Contrast echocardiography improves accuracy and reduces interreader variability on left ventricular (LV)functional analyses inthe settingof two-dimensional (2D) echocardiography. Theneedfor contrast imaging using three-dimensional (3D) echocardiography is less defined. The aim of this multicenter study was to define the accuracy and interreader agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography for the assessment of LV volumes and ejection fraction (EF). Methods: A multicenter, open-label study was conducted including 63 patients, using intrasubject comparisons to assess the agreement of unenhanced and contrast-enhanced 2D and 3D echocardiography as well as…
Echocardiographic and lung ultrasound characteristics in ambulatory patients with dyspnea or prior heart failure.
2013
Purpose Lung ultrasound (LUS) represents a novel, noninvasive method in the assessment of extravascular lung water. We investigated the utility of LUS in ambulatory subjects with dyspnea or prior heart failure (HF). Methods We studied 81 ambulatory subjects with HF history or dyspnea who underwent transthoracic echocardiography (TTE) with LUS of 8 zones. Subjects with heart transplantation or pulmonary conditions known to interfere with LUS were excluded. A reviewer blinded to the clinical data performed echocardiographic measurements and quantified B-lines (reverberation artifacts arising from the pleural line). Results Of 81 subjects, 74 (91%) (median age 66 years, 39% men, median left ve…
Exercise echocardiography for the evaluation of patients after nonsurgical coronary artery revascularization.
1993
Objectives. The purpose of this study was to demonstrate the accuracy of stress echocardiography for detecting the progression of coronary artery disease after nonsurgical revascularization. Background. The expanding role of nonsurgical coronary revascularization procedures mandates the development of sensitive noninvasive techniques for tbe detection of recurrent ischemia. Methods. Bicycle stress echocardiography was performed in a series of 86 patients 6.5 ±1.3 months after a revascularization procedure. Seven patients were excluded from analysis because of poor echocardiographic image quality. Results. Digital analysis achieved a sensitivity of 83% for the entire group and a specificity …
Cardiac Injury in COVID-19–Echoing Prognostication∗
2020
Background Myocardial injury is frequent among patients hospitalized with coronavirus disease-2019 (COVID-19) and is associated with a poor prognosis. However, the mechanisms of myocardial injury remain unclear and prior studies have not reported cardiovascular imaging data. Objectives This study sought to characterize the echocardiographic abnormalities associated with myocardial injury and their prognostic impact in patients with COVID-19. Methods We conducted an international, multicenter cohort study including 7 hospitals in New York City and Milan of hospitalized patients with laboratory-confirmed COVID-19 who had undergone transthoracic echocardiographic (TTE) and electrocardiographic…
Direct measurement of left ventricular outflow tract by transthoracic real-time 3D-echocardiography increases accuracy in assessment of aortic valve …
2007
Evaluation of aortic valve stenosis is a major clinical application of echocardiography. The widely employed continuity equation requires determination of the left ventricular outflow tract (LVOT) area. We aimed at testing whether direct area measurement in a volume data set is superior to conventional calculation from the LVOT diameter.We performed LVOT measurement in 20 normal subjects and 83 patients with moderate to severe aortic stenosis with a transthoracic real-time three-dimensional echocardiography (3D-TTE) technique in two systolic frames. The off-line 3D-evaluation allows full choice of section planes within the acquired volume data set. The aortic valve area was calculated from …