Search results for " Electrokinetic"

showing 10 items of 70 documents

Capillary electrochromatography analysis of hormonal cyclic and linear peptides.

2001

The retention behavior of linear and cyclic peptides has been studied by capillary electrochromatography (CEC) with a variety of different n-alkyl silica reversed-phase sorbents and also with mixed-mode phases containing both strong cation-exchange (sulfonic acid) and n-alkyl groups bonded onto the silica surface, using eluents ranging from pH 2.0 to pH 5.0. Depending upon the amino acid sequence, electrochromatographic retention of the peptides was strongly affected by the composition of the eluent, its pH value, and the choice of sorbent packed into the capillaries. The dominant separation processes operating with these charged analytes could be modulated inter alia by the content of orga…

chemistry.chemical_classificationCapillary electrochromatographyChromatographySilicon dioxideSulfonic acidSilicon DioxidePeptides CyclicCyclic peptideHormonesAnalytical Chemistrychemistry.chemical_compoundColumn chromatographyCapillary electrophoresischemistryElectrochromatographyAcetonitrileOligopeptidesChromatography Micellar Electrokinetic CapillaryAnalytical chemistry
researchProduct

Chromatographic quantitation of the hydrophobicity of ionic compounds by the use of micellar mobile phases

1998

Abstract Many biologically active compounds of interest in structure–activity relationships are ionic at physiological pH. However, ionic organic compounds are only weakly or not retained in conventional RPLC which impedes the chromatographic estimation of their hydrophobicity and the development of quantitative retention–activity relationship studies. The use of micellar mobile phases allows the retention of ionic compounds. Hydrophobic and electrostatic forces govern the retention of ionic compounds in micellar liquid chromatography. In this paper three different retention models log k–log P for ionic compounds are tested (P=partition coefficient). The retention model (log k=a log P+bα+c)…

chemistry.chemical_classificationChromatographyChemistryOrganic ChemistryIonic bondingBiological activityGeneral MedicineBiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryAmino acidPartition coefficientchemistry.chemical_compoundMicellar liquid chromatographyIonic compoundDerivatizationJournal of Chromatography A
researchProduct

Discontinuous electrokinetic chromatography of parabens using different substituted resonances as pseudostationary phases

1999

Resorcarene derivatives, negatively charged even at moderate pH, were synthesized and employed as pseudostationary phases to achieve mobilities exceeding that of the electroosmotic flow. Under these conditions, a discontinuous electrolyte system was developed which allows the separation of four uncharged homologous 4-hydroxybenzoic esters (parabens) within a zone of resorcarene electrolyte, and the detection of these UV active compounds in a resorcarene-free zone, free from the high UV background absorbance of the resorcarenes. Resorcarenes, with differently charged functionalities (carboxylate and phosphate groups) to provide the electrophoretic mobility and with alkyl residues of differen…

chemistry.chemical_classificationChromatographyClinical BiochemistryParabensElectrolyteResorcinareneBiochemistryAnalytical ChemistryAbsorbanceElectrophoresischemistry.chemical_compoundElectrokinetic phenomenachemistryCarboxylateSelectivityAlkylChromatography Micellar Electrokinetic CapillaryElectrophoresis
researchProduct

A micellar liquid chromatographic method for quality control of pharmaceutical preparations containing tricyclic antidepressants

2002

Micellar liquid chromatography methods for quality control of pharmaceutical preparations (capsules, pills, tablets, injections) containing the tricyclic antidepressants amineptine, amitriptiline, clomipramine, doxepin, imipramine, melitracen and nortriptyline alone or together with other CNS drugs like diazepam, medazepam and perphenazine are described. The methods using micellar solutions of cetyltrimethylammonium bromide as mobile phases and UV detection are rapid and reproducible. Due to the versatility of interactions in micellar liquid chromatography, it is possible determine highly hydrophobic compounds such as TCAs in a short time using mobile phases containing low organic solvent c…

chemistry.chemical_classificationChromatographyOrganic ChemistryClinical BiochemistryMelitracenDoxepinBiochemistryMicellar electrokinetic chromatographyDosage formAnalytical ChemistryMedazepamchemistryMicellar liquid chromatographyMicellar solutionsmedicineTricyclicmedicine.drugChromatographia
researchProduct

Determination of cationic surfactants by capillary zone electrophoresis and micellar electrokinetic chromatography with deoxycholate micelles in the …

2000

Mixtures of the cationic surfactants benzalkonium chloride (BKC) and cetylpyridinium chloride (CPC) were quickly resolved and reproducibly and reliably determined by using background electrolytes (BGEs) containing 80 mM borate, pH 8.5, bile salts and large concentrations of an organic solvent. When the bile salt is present, the separation mechanism changes from capillary zone electrophoresis (CZE) to a mixed micellar electrokinetic chromatography (MEKC)-CZE, with predominant MEKC interactions, which lead to an excellent resolution of all the solutes, including the C12-C18 homologues of BKC and CPC. A BGE containing 50 mM sodium deoxycholate and 30% ethanol for an extreme resolution, or 20% …

chemistry.chemical_classificationChromatographyResolution (mass spectrometry)Organic ChemistryCationic polymerizationSalt (chemistry)General MedicineCetylpyridinium chlorideBiochemistryMicelleMicellar electrokinetic chromatographyAnalytical Chemistrychemistry.chemical_compoundBenzalkonium chlorideSurface-Active AgentsCapillary electrophoresischemistryCationsmedicineSolventsMicellesmedicine.drugChromatography Micellar Electrokinetic CapillaryDeoxycholic AcidJournal of chromatography. A
researchProduct

Fast determination of prominent carotenoids in tomato fruits by CEC using methacrylate ester-based monolithic columns.

2007

In this study, the major carotenoids (beta-carotene and lycopene) present in tomato fruits were analyzed by CEC with a methacrylate ester-based monolithic column. The effects of the porogenic solvent ratio, and the hydrophobicity of bulk monomer employed were examined on carotenoids separations. A fast separation of these analytes was achieved in less than 5.0 min in a mobile phase containing 35% THF, 30% ACN, 30% methanol, and 5% of a 5 mM Tris aqueous buffer, pH 8, with lauryl methacrylate-based monoliths. The CEC method was evaluated in terms of detection limit and reproducibility (retention time, area, and column preparation) with values below 1.6 microg/mL and 7.2%, respectively. The p…

chemistry.chemical_classificationDetection limitAnalyteMonolithic HPLC columnChromatographyTime FactorsChemistryClinical BiochemistryBreedingMethacrylatebeta CaroteneBiochemistryCarotenoidsLycopeneAnalytical ChemistrySolventchemistry.chemical_compoundLycopeneSolanum lycopersicumFruitMethacrylatesMethanolCarotenoidChromatography Micellar Electrokinetic CapillaryElectrophoresis
researchProduct

Determination of alkylphenol ethoxylates by micellar electrokinetic chromatography with bile salts

2001

Octyl- and nonylphenol ethoxylates (OPEs and NPEs) with different numbers of ethoxy units (average values: n = 10 and N = 40 for OPEs, and n = 10 for NPEs) were separated by micellar electrokinetic chromatography under positive polarity using an 80 mM borate buffer of pH 8.5 containing sodium deoxycholate (SDC) or sodium cholate (SC). When sodium dodecyl sulfate (SDS) was added to the background electrolyte (BGE) in the absence of the bile salt, a single peak at a migration time longer than that of the EOF was obtained. Substituting the SDS by a bile salt, the homologues were resolved. At the same bile salt concentration, resolution between the homologues was higher with SDC than using SC. …

chemistry.chemical_classificationDetection limitChromatographyAlkylphenolLinear alkylbenzeneClinical BiochemistrySalt (chemistry)BiochemistryMicellar electrokinetic chromatographyAnalytical ChemistryNonylphenolchemistry.chemical_compoundchemistrySodium dodecyl sulfateSodium CholateELECTROPHORESIS
researchProduct

Determination of major carotenoids in vegetables by capillary electrochromatography.

2006

A simple and rapid method for the isocratic separation and determination of carotenoids (carotenes and xanthophylls) in vegetables by CEC is described. The capillary column (100 microm ID, 25 cm effective length) was packed with 3 microm Hypersil ODS particles. The optimized mobile phase contained 60% ACN, 35% THF and 5% of a 5 mM Tris aqueous buffer of pH 8. beta-Carotene, lycopene and lutein were separated with efficiencies of 66 000-128 000 plates/m within a short time (less than 12 min for the last peak eluted, 13/13'-cis-beta-carotene). An excellent resolution of the three carotenoids, as well as partial resolution of their geometrical isomers, was achieved. Application to the determin…

chemistry.chemical_classificationLuteinCapillary electrochromatographyChromatographyResolution (mass spectrometry)Molecular StructureElutionReproducibility of ResultsFiltration and SeparationStereoisomerismCarotenoidsLycopeneAnalytical Chemistrychemistry.chemical_compoundElectrochromatographychemistryXanthophyllVegetablesCarotenoidChromatography Micellar Electrokinetic CapillaryJournal of separation science
researchProduct

Biopartitioning micellar chromatography: An alternative high-throughput method for assessing the ecotoxicity of anilines and phenols

2007

An investigation of the use of the chromatographic retention (log k) as an in vitro approach for modelling the toxicity to Fathead Minnows of anilines and phenols is developed. A data set of 65 compounds with available experimental toxicity data was used. Log k data at three pH values were used for the compounds classification and two groups or 'MODEs' were identified. For one 'MODE' a quantitative retention-activity relationship (QRAR) model was calculated. Finally, it was used to estimate the toxicity to Fathead minnows of anilines and phenols for which experimental data are not available. These estimations were compared to those obtained from another toxicity (to Tetrahymena pyriformis) …

chemistry.chemical_classificationQuantitative structure–activity relationshipAniline CompoundsChromatographyToxicity dataTetrahymena pyriformisClinical BiochemistryCyprinidaeQuantitative Structure-Activity RelationshipAromatic amineExperimental dataCell BiologyGeneral MedicineBiochemistryAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryTetrahymena pyriformisToxicityAnimalsSpectrophotometry UltravioletPhenolsEcotoxicityChromatography Micellar Electrokinetic CapillaryJournal of Chromatography B
researchProduct

Application of computational fluid dynamics technique in electrodialysis/reverse electrodialysis processes

2022

This Chapter treats the application of CFD technique in ED/RED processes. CFD simulations are able to predict flow and mass transfer in channels filled with spacers or membrane profiles, by providing dimensionless correlations useful for process models. At a larger scale, manifolds of the stack and inlet/ outlet zones of the channel can be simulated. Numerical models can include the computation of the electrical potential, thus characterizing the process performance. Direct numerical simulations can elucidate the complex phenomenology of overlimiting transport and of chaotic electrokinetic flows.

modellingSettore ING-IND/26 - Teoria Dello Sviluppo Dei Processi ChimiciReverse electrodialysiselectroconvectionReverse electrodialysimass transportelectrokinetic instabilityElectrodialysisElectrodialysiCFDElectrodialysis; Reverse electrodialysis; CFD; modelling; mass transport; electroconvection; electrokinetic instabilitySettore ING-IND/19 - Impianti Nucleari
researchProduct