Search results for " Elettroni"
showing 10 items of 1073 documents
Uncertainty evaluation in the measurements for the electric power quality analysis
2013
The paper deals with the uncertainty estimation in the measurements performed to assess the electric power quality. In a first steps, according to the 'ISO - Guide to Expression of the Uncertainty in Measurements' all the error sources, which give a significant contribution to the combined uncertainty associated to the measurement results, are identified. Successively, in order to analyze how the errors propagate through the measurement chain, a Monte Carlo based approach is proposed. The method exploits an ad-hoc developed simulator of the measurement process, which takes into account the particular way of propagation of all the identified error sources. Eventually, with the aim of validat…
Electric Power Quality Evaluation in the Presence of Electromagnetic Emissions
2013
The measurements for the assessment of the electric power quality are often carried out in hostile electromagnetic environments. The aim of the paper is analyzing if and how both radiated and conducted electromagnetic emissions can disturb the measurement system used to quantify these disturbances. To achieve the target, an experimental approach is proposed, which, by means of a simple and fast test, allows establishing if the real electromagnetic environment, where power quality analysis is performed, can alter the measurements. © 2013 IEEE.
Experimental EMF characterization of a secondary substation
2015
This paper presents the results of the experimental EMC characterization of a new medium/low voltage (MV/LV) secondary substation, which was developed in the framework of the research project "NEW CAB ELARC". It has two MV/LV transformers, with total rated power of 1000 kVA. To perform the experimental characterization, firstly an analysis was performed of the Italian and European standards recommendations. Different approaches were highlighted and the most appropriate procedures were identified for the measurement of the magnetic fields emissions, at power systems frequency (50 Hz) in steady-state conditions. A dedicated test lab was set up for the secondary substation characterization. Th…
Smart plugs: A low cost solution for programmable control of domestic loads
2014
International audience; Balancing energy demand and production is becoming a more and more challenging task for energy utilities. This is due to a number of different reasons among which the larger penetration of renewable energies which are more difficult to predict and the meagre availability of financial resources to upgrade the existing power grid. While the traditional solution is to dynamically adapt energy production to follow the time-varying demand, a new trend is to drive the demand itself by means of Direct Load Control (DLC). In this paper we consider a scenario where DLC functionalities are deployed at a large set of small deferrable energy loads, like appliances of residential…
Integration of distributed on site control actions via combined photovoltaic and solar panels system
2009
A systematic evaluation of the potential energy saving and CO2 emissions reduction on buildings was carried out, when a renewable energy system is locally installed. The exploitation of a combined solar and photovoltaic system and the integration of suitable energy management actions were deeply investigated. A model of these solar and photovoltaic components has been developed and included within a complete house simulator, capable to precisely figure out the daily electric energy consumptions of typical apartments and to measure the positive actions induced by the added renewable energy. Saving up to 40% on the energy consumptions and even more savings on wiring losses seems to be easily …
An experimental study on relationship between LED lamp characteristics and non image-forming
2017
The general aim of the experimental study, presented in this paper, was that to investigate the relationship between the characteristics of five different types of LED (Light Emitting Diode) lamps, which are nowadays those allowing the highest energy consumption reduction, and the humans non image-forming (NIF) reactions.
A PC-based wattmeter for high accuracy power measurements
2010
This paper proposes the use of a commercial data acquisition board (DAQ) connected to a common personal computer for high accuracy power measurements. In the paper the set up of the PC-based wattmeter is described and an experimental evaluation of its metrological performances is made by means of the comparison with a simultaneous coherent digital sampling wattmeter realized with two high-precision DMMs Hewlett Packard Model 3458 A. In both cases the power source is a Fluke 6100A/E electrical power standard. © 2010 IEEE.
A novel approach to current transformer characterization in the presence of harmonic distortion
2009
The current transformer (CT) performance under distorted waveform conditions is usually characterized by means of the frequency-response test. In this paper, a new way to characterize CTs, closer to real operation conditions, is proposed. The harmonic phase-angle and ratio errors are measured using a nonsinusoidal current composed of fundamental and one harmonic with adjustable phase shift. The new method was tested by determining the performance of two metering class CTs commonly used by the Italian power company. The errors measured using the proposed approach are larger than the ones obtained with the frequency response. This result suggests that the frequency-response approach for the e…
Oil filled MV/LV Power Transformer Behavior in Narrow Band Power Line Communication Systems
2012
The aim of this paper is to characterize oil-filled power transformers in the narrow-band power-line communication (PLC) frequency range of 50-150 kHz. A new model is proposed for such type of a transformer, in the aforementioned frequency range of interest, in order to study its influence on the signal transmission and to investigate the possibility that the PLC signal can cross the power transformer itself. The new model is simpler than those previously proposed in literature, and it can be used in the whole frequency range available for NB PLC according to the CENELEC EN 50065-1 A-band. In order to validate the model, simulation and measurement results are compared for four oil-filled po…
An Innovative Measurement Approach for Load Flow Analysis in MV Smart Grids
2016
This paper proposes a novel measurement procedure for load flow analysis in medium voltage (MV) smart grids. The new approach is based on power measurements at low voltage (LV) side of MV/LV distribution substations. Such measurements are carried out by means of power quality analyzers. If compared with the load flow methods based on measurements at the MV side, the proposed approach has a lower cost and it offers an equally reliable measurement system. The proposed algorithm takes the basic concept of the current summation backward/forward method; some modifications are introduced to use LV load powers measurements. To this aim, the MV/LV power transformer is properly modeled and taken int…