Search results for " Error."
showing 10 items of 1034 documents
Subjective Satisfaction in Long-term Orthokeratology Patients
2013
Purpose: To AU3 evaluate the subjective satisfaction in visual stability, night vision complains, and light distortion phenomena, and also the number of hours and days per week of lens wear, in patients with myopia undergoing orthokeratology (OK) treatment for at least 1 year. Methods: A visual analog scale (VAS) questionnaire containing 18 items was administered to 44 patients, 29 women and 15 men (mean age, 24.39 6 9.11 years), with a baseline spherical equivalent refractive error of 22.40 6 0.94 diopters and astigmatism up to 20.5 diopters. Average treatment period by the time of data collection was 19 6 7 months. Patients rated their satisfaction with the correction, with complaints of …
Light distortion of soft multifocal contact lenses with different pupil size and shape
2020
Purpose: To study the light distortion effects of soft multifocal contact lenses and the influence of different pupil size and shape.Methods: A total of 14 eyes of 7 healthy contact lens users (mean age 28.6 +/- 8.5 years) were recruited. The "Light Disturbance Analyser" device was employed for light characterization. The selected lenses were the monthly disposable "Biofinity multifocal" (CooperVision, CA, USA), both centre-distance and centre-near designs (addition power + 2.50 D). Two circular pupils of 3 mm and 5 mm of diameter, and an elliptical shape (3 horizontal and 5 vertical mm) were used. Metrics such as the light distortion index (LDI), best-fit circle radius and its irregularity…
EMG, heart rate, and accelerometer as estimators of energy expenditure in locomotion.
2014
AB Purpose: Precise measures of energy expenditure (EE) during everyday activities are needed. This study assessed the validity of novel shorts measuring EMG and compared this method with HR and accelerometry (ACC) when estimating EE. Methods: Fifty-four volunteers (39.4 +/- 13.9 yr) performed a maximal treadmill test (3-min loads) including walking with different speeds uphill, downhill, and on level ground and one running load. The data were categorized into all, low, and level loads. EE was measured by indirect calorimetry, whereas HR, ACC, and EMG were measured continuously. EMG from quadriceps (Q) and hamstrings (H) was measured using shorts with textile electrodes. Validity of the met…
Effect of innervation zones in estimating biceps brachii force-EMG relationship during isometric contraction
2012
Measuring muscle forces in vivo is invasive and consequently indirect methods e.g., electromyography (EMG) are used in estimating muscular force production. The aim of the present paper was to examine what kind of effect the disruption of the physiological signal caused by the innervation zone has in predicting the force/torque output from surface EMG. Twelve men (age 26 (SD ±3)years; height 179 (±6)cm; body mass 73 (±6)kg) volunteered as subjects. They were asked to perform maximal voluntary isometric contraction (MVC) in elbow flexion, and submaximal contractions at 10%, 20%, 30%, 40%, 50% and 75% of the recorded MVC. EMG was measured from biceps brachii muscle with an electrode grid of 5…
Missing Cases of Herpes Simplex Virus (HSV) Infection of the Central Nervous System When the Reller Criteria Are Applied for HSV PCR Testing: a Multi…
2019
ABSTRACT Previous studies suggested that herpes simplex virus (HSV) PCR testing can be safely deferred in patients with normal cerebrospinal fluid (CSF) white blood cell (WBC) counts and protein levels as long as they are older than 2 years of age and are not immunocompromised, the so-called Reller criteria. In this multicenter study, we retrospectively assessed the validity of these screening criteria in our setting. A total of 4,404 CSF specimens submitted for HSV PCR testing to the respective microbiology laboratories at the participating hospitals between 2012 and 2018 were included. Six commercially available HSV PCR assays were used across the participating centers. Ninety-one of the …
Dynamic angular three-dimensional measurement of multisegmental thoracolumbar motion in vivo.
2008
Study design Method validation and in vivo motion segment study. Objective To determine in healthy subjects in vivo intervertebral segmental kinematics and coupled motion behavior in all 3 planes simultaneously for 3 segments and to evaluate whether these results differ from those in the normal population according to the literature. Summary of background data Few studies have provided a direct invasive approach to investigate segmental kinematics in vivo. Dynamic recordings of 3-dimensional segmental motion patterns of adjacent segments have rarely been reported. To date, no studies have examined the 3-dimensional segmental movements of the thoracolumbar junction in vivo in detail. Methods…
Error in Intensive Care
2014
Objective To identify the psychological repercussions of an error on professionals in intensive care and to understand their evolution. To identify the psychological defense mechanisms used by professionals to cope with error. Design Qualitative study with clinical interviews. We transcribed recordings and analysed the data using an interpretative phenomenological analysis. Setting Two ICUs in the teaching hospitals of Besancon and Dijon (France). Subjects Fourteen professionals in intensive care (20 physicians and 20 nurses). Interventions None. Measurements and main results We conducted 40 individual semistructured interviews. The participants were invited to speak about the experience of…
Poor patient awareness and frequent misdiagnosis of migraine: findings from a large transcontinental cohort.
2019
Background and purpose Although migraine is the second most disabling condition worldwide, there is poor awareness of it. The objective was to assess the awareness of migraine and previous diagnostic and therapeutic consultations and treatments in a large international population of migraineurs. Methods This was a multicentre study conducted in 12 headache centres in seven countries. Each centre recruited up to 100 patients referred for a first visit and diagnosed with migraine. Subjects were given a structured clinical questionnaire-based interview about the perceptions of the type of headache they suffered from, its cause, previous diagnoses, investigations and treatments. Results In all,…
Objective vs Subjective Vault Measurement After Myopic Implantable Collamer Lens Implantation
2009
PURPOSE: To evaluate the relationship between subjective measurements of vault and objective values measured with Visante optical coherence tomography (OCT) in eyes receiving an implantable contact lens (ICL) for myopia correction. DESIGN: Observational cross-sectional study. METHODS: SETTING: Fernández-Vega Ophthalmological Institute, Oviedo, Spain. PATIENTS: Four hundred and fifty-two eyes from 246 patients were elected to be implanted with a Visian ICL V4 (STAAR Surgical Inc, Monrovia, California, USA). OBSERVATION PROCEDURES: Subjective and objective measurements of vault after implantation of ICL. MAIN OUTCOME MEASURES: Subjective vault classified in 5 levels assessed using an optical …
Effects of whole-body vertical shock-type vibration on human ability for fine manual control
1991
The effects of vertical (z-axis) whole-body shock-type vibration on the ability for fine manual control were examined. The amplitudes and frequency of the shocks was varied, but a constant frequency-weighted acceleration of 1.25 m/s2 r.m.s. was maintained. The examination of the shock's effects was carried out using an experimental system that simulated the actual workplace of earth-moving machinery. Control was measured using a first-order pursuit tracking-test, in which a seated subject was asked to use both hands to direct a cursor on a monitor using a steering wheel. Although the magnitude of shocks (peak amplitude of 6-10 m/s2) and the number of shocks per unit time (shock cycle of 10-…