Search results for " Error."

showing 10 items of 1034 documents

Phase dynamics in graphene-based Josephson junctions in the presence of thermal and correlated fluctuations

2014

In this work we study by numerical methods the phase dynamics in ballistic graphene-based short Josephson junctions. The supercurrent through a graphene junction shows a non-sinusoidal phase-dependence, unlike a conventional junction ruled by the well-known d.c. Josephson relation. A superconductor-graphene-superconductor system exhibits superconductive quantum metastable states similar to those present in normal current-biased JJs. We explore the effects of thermal and correlated fluctuations on the escape time from these metastable states, when the system is stimulated by an oscillating bias current. As a first step, the analysis is carried out in the presence of an external Gaussian whit…

Josephson effectTIMING ERRORSNON-GAUSSIAN NOISEFOS: Physical sciencesBROWNIAN-MOTIONSwitching timeSuperconductivity (cond-mat.supr-con)MetastabilityCondensed Matter::SuperconductivityMesoscale and Nanoscale Physics (cond-mat.mes-hall)NOISE ENHANCED STABILITY; ZERO-VOLTAGE STATE; NON-GAUSSIAN NOISE; RESONANT ACTIVATION; ESCAPE-TIME; METASTABLE STATE; BISTABLE SYSTEM; BROWNIAN-MOTION; TIMING ERRORS; FABRY-PEROTMETASTABLE STATEBISTABLE SYSTEMFABRY-PEROTBrownian motionsupercurrentPhysicsESCAPE-TIMERESONANT ACTIVATIONCondensed Matter - Mesoscale and Nanoscale PhysicsCondensed matter physicsCondensed Matter - SuperconductivitydiffusionSupercurrentBiasingCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsNOISE ENHANCED STABILITYZERO-VOLTAGE STATEColors of noiseNoise (radio)
researchProduct

Analyzing the impact of using the SRP (Simplified roughness parameterization) method on soil moisture retrieval over different regions of the globe

2015

International audience; This paper focuses on a new approach to account for soil roughness effects in the retrieval of soil moisture (SM) at L-band in the framework of the SMOS (Soil Moisture and Ocean Salinity) mission: the Simplified Roughness Parameterization (SRP). While the classical retrieval approach considers SM and τ nad (vegetation optical depth) as retrieved parameters, this approach is based on the retrieval of SM and the TR parameter combining τ nad and soil roughness (TR τ nad + Hr /2). Different roughness parameterizations were tested to find the best correlation (R), bias and unbiased RMSE (ubRMSE) when comparing homogeneous retrievals of SM and in situ SM measurements carri…

L bandVegetation optical depth010504 meteorology & atmospheric sciencesMean squared errorvegetation mapping0211 other engineering and technologiesSampling (statistics)[SDU.STU]Sciences of the Universe [physics]/Earth SciencesSoil science02 engineering and technologySurface finish01 natural sciencesL-bandHomogeneousEnvironmental sciencesoil measurementsmicrowave radiometrysoil moistureWater contentSoil roughness[SPI.SIGNAL]Engineering Sciences [physics]/Signal and Image processingmathematical model021101 geological & geomatics engineering0105 earth and related environmental sciences
researchProduct

Elaboración de modelos 3D de diferentes morfologías y escalas utilizando técnicas Structure-from-Motion y fotografías terrestres

2016

En este trabajo se evalúan los métodos de foto-reconstrucción automatizada basados en el uso conjunto de las técnicas Structure from Motion (SfM) y Multi-View Stereo (MVS) para medir, monitorizar y cuantificar la dinámica de tres formas geomorfológicas: i) el glaciar rocoso del Corral del Veleta (Granada, España), ii) un paisaje de cárcavas de tipo calanchi (Sicilia, Italia) y ii) cinco pequeñas cabeceras de cárcava (Cáceres, España). Se incluyen en este trabajo los resultados sobre la precisión, utilidad y aplicabilidad de estas técnicas. Para la cuantificación de la precisión se utilizan el error cuadrático medio (RMSE) de los puntos de control que se emplean en la georreferenciación y la…

Laser scanningMean squared errorSettore GEO/04 - Geografia Fisica E GeomorfologiaGeography Planning and DevelopmentPoint cloudPaleontologyRock glacierGeologyPoint cloudGeographyPhotogrammetryRelative precision ratioEarth-Surface ProcesseBenchmark (surveying)Terrestrial laser scanner3D Photo-reconstructionSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliDigital elevation modelScale (map)Earth-Surface ProcessesRemote sensingCuaternario y Geomorfología
researchProduct

Posterior chamber phakic intraocular lenses after penetrating keratoplasty.

2009

Purpose To evaluate the efficacy, predictability, and safety of a phakic posterior chamber intraocular Collamer lens (ICL) after penetrating keratoplasty (PKP). Setting Fernandez-Vega Ophthalmological Institute, Oviedo, Spain. Methods A myopic or toric ICL was implanted after PKP in eyes unable to wear glasses or contact lenses and for which corneal laser surgery was contraindicated. The uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), refractive error, and endothelial cell count were recorded preoperatively and 24 months postoperatively. Results Preoperatively, the 15 eyes had myopia from −2.00 to −17.00 diopters (D) or astigmatism from −1.50 to −7.00 D. …

Laser surgeryAdultMaleRefractive errormedicine.medical_specialtyPhakic Intraocular Lensesgenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensCell CountAstigmatismPhakic intraocular lensSafety indexPostoperative ComplicationsLens Implantation IntraocularRefractive surgeryOphthalmologymedicineMyopiaHumansProspective StudiesDioptrebusiness.industryEndothelium CornealAstigmatismMiddle Agedmedicine.diseaseeye diseasesSensory SystemsOphthalmologyTreatment OutcomeSurgeryFemalesense organsbusinessKeratoplasty PenetratingJournal of cataract and refractive surgery
researchProduct

Femtosecond laser for residual refractive error correction after refractive lens exchange with multifocal intraocular lens implantation.

2008

Purpose To assess visual and refractive outcomes of femtosecond laser for residual refractive error correction after refractive lens exchange (RLE) with multifocal intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Methods Fifty-three eyes of 31 consecutive patients were submitted to femtosecond laser surgery after RLE with multifocal IOL implantation. Patients showed an average manifest refractive error (D) of M , 0.200 ± 0.490; J 0 , −0.051 ± 0.532; and J 45 , −0.007 ± 0.371. Visual acuity (VA) was measured at distance and near vision before and six months after the surgery. Results At six months after surgery, mean …

Laser surgeryMalemedicine.medical_specialtyRefractive errorVisual acuitygenetic structuresmedicine.medical_treatmentKeratomileusis Laser In SituAcrylic ResinsVisual AcuityKeratomileusisIntraocular lensRefraction OcularPostoperative ComplicationsLens Implantation IntraocularOphthalmologymedicineMyopiaHumansProspective StudiesDioptreAgedLenses Intraocularmedicine.diagnostic_testbusiness.industryCorneal TopographyMultifocal intraocular lensMiddle AgedCorneal topographymedicine.diseasePrognosiseye diseasesOphthalmologyHyperopiaFemaleLasers Excimersense organsmedicine.symptombusinessFollow-Up StudiesAmerican journal of ophthalmology
researchProduct

Enabling XCSF to cope with dynamic environments via an adaptive error threshold

2020

The learning classifier system XCSF is a variant of XCS employed for function approximation. Although XCSF is a promising candidate for deployment in autonomous systems, its parameter dependability imposes a significant hurdle, as a-priori parameter optimization is not feasible for complex and changing environmental conditions. One of the most important parameters is the error threshold, which can be interpreted as a target bound on the approximation error and has to be set according to the approximated function. To enable XCSF to reliably approximate functions that change during runtime, we propose the use of an error threshold, which is adapted at run-time based on the currently achieved …

Learning classifier systemComputer scienceError thresholdComputer Science::Neural and Evolutionary Computation0102 computer and information sciences02 engineering and technologyFunction (mathematics)01 natural sciencesSet (abstract data type)Function approximation010201 computation theory & mathematicsApproximation error0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processingAlgorithmProceedings of the 2020 Genetic and Evolutionary Computation Conference Companion
researchProduct

Proper use of medical language: Main problems and solutions

2015

[EN]: Medical language should be characterized by its precision, emotional neutrality and stability. The effective communication of results of scientific studies depends on compliance with current standards of drafting and style; texts with defects can hinder interest in the findings. In this study, we discuss some of the most common problems and errors in medical language, including the abuse of abbreviations and foreign words, the use of improper words, syntax errors and solecisms, the most common errors in titles and the abuse of capital letters and the gerund. Investigators have effective tools for dealing with these problems, such as quality texts, critical dictionaries of questions an…

Lenguaje médicoSpanish languageScientific writingGerundbusiness.industrymedia_common.quotation_subjectUnified Medical Language SystemGeneral MedicineScientific styleEscritura científicaLinguisticsArticleMedical languageCompliance (psychology)Style (sociolinguistics)Corrección lingüísticaMedicineEstilo científicoQuality (business)NeutralitySyntax errorbusinessLanguage correctionmedia_commonRevista Clinica Espanola
researchProduct

Graphic representation of data resulting from measurement comparison trials in cataract and refractive surgery.

2003

* BACKGROUND AND OBJECTIVES: The evaluation of new diagnostic measurement devices allows intraindividual comparison with an established standard method. However, reports in journal articles often omit the adequate incorporation of the intraindividual design into the graphic representation. * PATIENTS AND METHODS: This article illustrates the drawbacks and the possible erroneous conclusions caused by this misleading practice in terms of recent method comparison data resulting from axial length measurement in 220 consecutive patients by both applanation ultrasound and partial coherence interferometry. * RESULTS: Graphic representation of such method comparison data should be based on boxplots…

LightConcordancemedicine.medical_treatmentCataract ExtractionDiagnostic Techniques Ophthalmologicalcomputer.software_genreEyeCataractOpticsRefractive surgeryComputer GraphicsMedicineHumansIntraindividual comparisonProspective StudiesGraphicsRepresentation (mathematics)Mathematical ComputingUltrasonographybusiness.industryAxial lengthRefractive ErrorsRefractive Surgical ProceduresOphthalmologyInterferometryMethod comparisonPartial coherence interferometryData Interpretation StatisticalArtificial intelligencebusinesscomputerNatural language processingOphthalmic surgery, lasersimaging : the official journal of the International Society for Imaging in the Eye
researchProduct

Molybdenum Trioxide Nanoparticles with Intrinsic Sulfite Oxidase Activity

2014

Sulfite oxidase is a mitochondria-located molybdenum-containing enzyme catalyzing the oxidation of sulfite to sulfate in the amino acid and lipid metabolism. Therefore, it plays a major role in detoxification processes, where defects in the enzyme cause a severe infant disease leading to early death with no efficient or cost-effective therapy in sight. Here we report that molybdenum trioxide (MoO3) nanoparticles display an intrinsic biomimetic sulfite oxidase activity under physiological conditions, and, functionalized with a customized bifunctional ligand containing dopamine as anchor group and triphenylphosphonium ion as targeting agent, they selectively target the mitochondria while bein…

LightPhotochemistryMetal NanoparticlesGeneral Physics and AstronomyMolybdenum trioxidechemistry.chemical_compoundSulfiteSulfite oxidaseElectrochemistryNanotechnologyGeneral Materials ScienceBifunctionalAmino Acid Metabolism Inborn ErrorsElectrodesSulfite oxidase deficiencyMolybdenumchemistry.chemical_classificationPhotonsBinding SitesNanowiresSulfite OxidaseGeneral EngineeringOxidesAmino acidKineticsEnzymechemistryBiochemistryNanoparticlesEnzyme mimicElectronicsZinc OxideOxidation-ReductionACS Nano
researchProduct

Interjections and Pragmatic Errors in Dubbing

2006

This paper consists of an analysis of the expressive secondary interjections found in the film Four Weddings and a Funeral and their equivalents in the Spanish and Catalan dubbed versions. The contrastive analysis of the interjections in the original English version compared with the Spanish and the Catalan dubbed versions shows that the strategies followed by the translators are different: literal translation is far more frequent in Spanish than in Catalan. Literal translation often implies an error that is pragmatic in nature since it derives from the misunderstanding of the pragmatic meaning that the interjection conveys.

Linguistics and LanguageSocial Sciences and HumanitiesInterjectionPhilosophyLiteral translationaudiovisual translationLanguage and LinguisticsLinguisticslanguage.human_languagepragmatic errorsinterjectionsdubbingEnglish versionlanguagetranslation strategiesCatalanSciences Humaines et SocialesMeaning (existential)Contrastive linguisticsContrastive analysis
researchProduct