Search results for " Extraction"
showing 10 items of 1344 documents
Matrix effects on solid-phase microextraction of organophosphorus pesticides from water
1997
Abstract This study develops a method for solid-phase microextraction (SPME) of eight organophosphorus pesticides, diazinon, fenthion, fenitrothion (sumithion), methyl-parathion, parathion, methyl-trithion, ethion and triazophos, from water. Determination is carried out by gas chromatography with nitrogen-phosphorus detection. To perform the SPME, poly(dimethylsiloxane) and polyacrylate fibers were initially compared on the basis of their absorption capacities for the selected pesticides, and polyacrylate was selected to accomplish the rest of assays. The main factors affecting the SPME process such as memory effect, stirring rate, extraction temperature and absorption-time profile were stu…
Gas chromatographic behaviour of urea herbicides
2001
Gas chromatographic conditions for determining eight phenylurea (chlortoluron, diuron, fluometuron, isoproturon, linuron, metabenzthiazuron, metobromuron and monuron) and one sulfonylurea (chlorsulfuron) herbicides were assessed. Degradation products of the herbicides formed in the injector were used for identification. Most phenylureas formed their respective carbamic acid methyl esters, metabenzthiazuron formed an aminobenzothiazol and chlorsulfuron formed an aminotriazine plus a phenylsulfonamide. On-column injection of standards using a BP10 capillary column was evaluated to identify the chromatographic behaviour. Detection limits ranged from 0.05 ng for chlorsulfuron to 3 ng for monuro…
Liquid chromatographic determination of trimethylamine in water.
2004
A method for the selective determination of trimethylamine (TMA) in aqueous matrices by liquid chromatography is reported. The proposed procedure is based on the derivatization of the analyte with 9-fluorenylmethyl chloroformate (FMOC) in a precolumn (Hypersil C18, 30 microm, 20 mm x 2.1 mm i.d.) connected on-line to the analytical column (LiChrosphere 100 RP18, 5 microm, 125 mm x 4 mm i.d.). Gradient elution was performed with a mixture of acetonitrile-water-0.05 M borate buffer (pH 9.0). The method has been applied to the direct determination of TMA in water within the 0.25-10.0 microg/ml concentration interval, and can also be adapted to the determination of TMA over the range 0.05-1.0 m…
Comparison of different methods for extraction of polycyclic aromatic hydrocarbons (PAHs) from Sicilian (Italy) coastal area sediments.
2012
This paper describes a work aimed at improving the conditions of an extraction method, coupling GC-MS determination, for the analysis without cleanup phase, of polycyclic aromatic hydrocarbons (PAHs) from sediment samples. The automatic Soxhlet extraction in warm mode (using Extraction System B-811 Standard, Buchi) has demonstrated advantages for automation, reduced extraction time, and lower solvent use than for conventional Soxhlet extraction. Under these conditions, the recoveries are very good as they resulted greater than 85 % and, in most of the cases, near 100 %. The repeatability is also satisfactory (relative standard deviation less than 15 %). The detection limits are also accepta…
Determination of organophosphorus pesticides in honeybees after solid-phase microextraction.
2001
A method based on solid-phase microextraction (SPME) followed by gas chromatography with nitrogen-phosphorus detection was developed for the purpose of determining 18 organophosphorus pesticide residues in honeybee samples (Apis mellifera). The extraction capacities of polyacrylate and poly(dimethylsiloxane) fibers were compared. The main factors affecting the SPME process, such as the absorption time profile, salt, and temperature, were optimized. The method involved honeybee sample homogenization, elution with an acetone:water solution (1:1) and dilution in water prior to fiber extraction. Moreover, the matrix effect on the extraction was evaluated. In samples spiked at the 0.2 mg kg(-1) …
Validating quantitative PCR assays for cell-free DNA detection without DNA extraction: Exercise induced kinetics in systemic lupus erythematosus pati…
2021
ABSTRACTCirculating cell-free DNA (cfDNA) has been investigated as a screening tool for many diseases. To avoid expensive and time-consuming DNA isolation, direct quantification PCR assays can be established. However, rigorous validation is required to provide reliable data in the clinical and non-clinical context. Considering International Organization for Standardization, as well as bioanalytical method validation guidelines we provide a comprehensive procedure to validate assays for cfDNA quantification from unpurified blood plasma. A 90 and 222 bp assay was validated to study the kinetics of cfDNA after exercise in patients with systemic lupus erythematosus. The assays showed ultra-low …
DETERMINATION OF PENTOBARBITAL IN BIOLOGICAL SAMPLES BY MICELLAR LIQUID CHROMATOGRAPHY
1999
A liquid chromatographic procedure for the determination of pentobarbital in urine and plasma samples is described. The proposed system uses a Spherisorb octadecyl-silane ODS-2 C18 analytical column, a guard column of similar characteristics, and a 0.02 M CTAB-15% 1-propanol at pH 7.5 mobile phase. The UV detector was set at 250 nm. Pentobarbital was isolated from urine and plasma samples by using a single solid phase extraction procedure with LMS cartridges. Mephobarbital was used as internal standard. Limits of detection were 0.53 μg/mL and 0.60 μg/mL in urine and plasma samples respectively. In both cases the coefficients of variation were lower than 6.5%, and the recoveries ranged betwe…
Determination of abamectin in citrus fruits by liquid chromatography-electrospray ionization mass spectrometry.
2000
Liquid chromatography coupled to electrospray mass spectrometry (LC-ES-MS) with positive ion detection was used to determine abamectin in oranges. MS conditions were optimized to achieve maximum sensitivity. The main ion for abamectin was [M+Na]+ at a fragmentor voltage of 180 V. Abundant structural information can be obtained at different fragmentor voltages. The detection limit for the standard solution was 12 pg injected, and good linearity and reproducibility were observed. Abamectin residues were extracted using matrix solid-phase dispersion. Orange samples were homogenized with C18 bonded silica placed onto a glass column and eluted with dichloromethane. Recoveries of the abamectin fr…
Selective and sentivive method based on capillary liquid chromatography with in-tube solid phase microextraction for determination of monochloramine …
2015
Abstract Due to the difficulties of working with chloramines, a critical examination of monochloramine standard preparation has been performed in order to select the best synthesis conditions. The analyte has been determined by in-tube solid phase extraction coupled to capillary liquid chromatography with UV detection (IT-SPME Capillary LC DAD). Potential factors affecting the response of monochloramine such as the pH of mobile phase and the volume of sample processed by IT-SPME Capillary LC DAD have been investigated and optimized. According to the results of the study, 0.1 mL or 4.0 mL of sample at neutral pH were loaded in the chromatographic system. A sensitive and selective method has …
Capillary zone electrophoresis for the determination of thiabendazole, prochloraz and procymidone in grapes
2001
Capillary zone electrophoresis with UV detection was applied to the simultaneous determination of thiabendazole, prochloraz and procymidone in grapes. Electrolyte conditions such as pH, composition and concentration of the buffer, addition of organic solvent and working voltage were checked to obtain a high-performance separation of the three fungicides (by measurement of separation efficiency and resolution). The most critical parameter was the pH of the running buffer. The best separation was achieved in 4 mM phosphate solution at pH 3.5. The repeatability of the migration times, expressed as RSD, was <0.44%. The three peaks were completely resolved with a separation efficiency up to 100 …