Search results for " FIX"

showing 10 items of 575 documents

Transverse fracture-dislocation of the sacrum: a diagnostic pitfall and a surgical challenge.

2002

Transverse fracture-dislocations of the sacrum are rare. Associated lesions of the lumbosacral spine as well as neurological injuries are common. Conventional radiographs of the pelvis often fail to clearly visualize the fracture. Delayed diagnosis increases the risk of progressive neurological disfunction. True lateral sacral views and CT-scans with 3-dimensional reconstructions are very helpful in establishing the full extent of the injury. These examinations should be considered in all patients with a history of high energy trauma and clinical signs indicating lumbosacral injury, such as severe low back pain and neurological disturbances of the lower extremities. The management of transv…

musculoskeletal diseasesAdultMalemedicine.medical_specialtySacrumNerve rootBone ScrewsJoint DislocationsFracture Fixation InternalDeformityMedicineHumansSpinal canalPelvisPalsyLumbar Vertebraebusiness.industryGeneral Medicinemusculoskeletal systemSacrumLow back painInternal FixatorsSurgeryRadiographymedicine.anatomical_structureSpinal FracturesSurgeryFemalemedicine.symptomNervous System DiseasesbusinessLumbosacral jointActa chirurgica Belgica
researchProduct

The Retrograde Tibial Nail: presentation and biomechanical evaluation of a new concept in the treatment of distal tibia fractures.

2013

Displaced distal tibia fractures require stable fixation while minimizing secondary damage to the soft tissues by the surgical approach and implants. Antegrade intramedullary nailing has become an alternative to plate osteosynthesis for the treatment of distal metaphyseal fractures over the past two decades. While retrograde intramedullary nailing is a standard procedure in other long bone fractures, only few attempts have been made on retrograde nailing of tibial fractures. The main reasons are difficulties of finding an ideal entry portal and the lack of an ideal implant for retrograde insertion. The Retrograde Tibial Nail (RTN) is a prototype intramedullary implant developed by our group…

musculoskeletal diseasesAdultMalemedicine.medical_specialtymedicine.medical_treatmentLong boneBone NailsOsteotomyProsthesis Designlaw.inventionIntramedullary rodFixation (surgical)lawmedicineHumansTibiaGeneral Environmental ScienceAgedOsteosynthesisbusiness.industryMiddle Agedmusculoskeletal systemSurgeryBiomechanical PhenomenaFracture Fixation IntramedullaryRadiographyTibial Fracturesmedicine.anatomical_structureTreatment OutcomeGeneral Earth and Planetary SciencesFemaleImplantAnklebusinessBone PlatesInjury
researchProduct

Posterior perilunate carpal dislocation associated with a multifragmentary distal radius fracture.

2009

Summary Dorsal perilunate wrist dislocations are rare. Associated carpal bones or radial styloid process fractures can occur and be included in the current classifications. The authors report an unusual association of dorsal perilunate wrist dislocation with a multifragmentary distal radius fracture. Such traumatic entity has never been previously described. Poor functional outcome may justify the inclusion of associated complex forearm bone fractures in wrist dislocation classifications.

musculoskeletal diseasesDorsumMalemedicine.medical_specialtyJoint DislocationsWristFracture Fixation InternalRadial styloid processForearmMedicineHumansRange of Motion ArticularCarpal Jointsbusiness.industryAnatomyMiddle AgedSurgerybody regionsRadiographyCarpal bonesmedicine.anatomical_structureForearm boneSurgeryDistal radius fractureDislocationbusinessRadius FracturesFollow-Up StudiesJournal of plastic, reconstructiveaesthetic surgery : JPRAS
researchProduct

Le Fratture di Rotula

2015

Patellar fractures are relatively uncommon, accounting for approximately 1% of all fractures. Non-operative treatment represents the best choice for undisplaced patellar fractures. However, surgery becomes necessary when fractures are displaced by more than 2 mm, and may include open reduction and internal fixation. Accurate reduction and rigid fixation are required in order to allow early knee mobilization and to obtain a better clinical outcome. Several techniques have been described for patellar fracture fixation, such as tension band wiring, interfragmentary screw fixation, and the combination of screw fixation and cerclage. In this article up-to-date diagnosis, classification and treat…

musculoskeletal diseasesFibrous jointmedicine.medical_specialtybusiness.industryTension band wiringmedicine.medical_treatmentfiberwirefratture di rotula fratture di ginocchio trauma rotulamusculoskeletal systemmedicine.diseaseSurgeryScrew fixationFixation (surgical)medicine.anatomical_structurefrattureOrthopedic surgerySettore MED/33 - Malattie Apparato LocomotoreMedicineInternal fixationPatella fracturebusiness
researchProduct

A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.

2018

Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…

musculoskeletal diseasesMalemedicine.medical_treatmentBone ScrewsKnee InjuriesBone NailsOsteotomy03 medical and health sciencesFracture Fixation InternalFractures Bone0302 clinical medicineCadaverFracture fixationmedicineCadaverInternal fixationHumansOrthopedics and Sports MedicineRange of Motion ArticularOrthodontics030222 orthopedicsbusiness.industryTension band wiring030208 emergency & critical care medicineGeneral MedicinePatellamusculoskeletal systemmedicine.diseaseBiomechanical Phenomenamedicine.anatomical_structureSurgeryFemaleQuadriceps tendonPatella fractureCadaveric spasmbusinessThe Journal of bone and joint surgery. American volume
researchProduct

In Silico Analysis of Bone Tension During Fixation of the Medial Malleolus Fracture After Ankle Joint Endoprosthesis

2020

Total ankle arthroplasty (TAR) is a procedure alternative to arthrodesis which enables the biomechanical stabilization of the ankle joint. The procedure is associated with a high risk of complications, including fractures of the medial malleolus. In this study, the finite element method (FEM), based on CT examinations, was used to model the ankle fracture fixation after TAR. Three types of fracture stabilization were considered: screw, Blount staple, and both screw and Blount staple. In the in silico model, the maximum stress tension was found at prosthetic junctions with the base, cone, and talar components of the tibial prosthesis. When the fracture was stabilized with the Blount staple, …

musculoskeletal diseasesOrthodonticsbusiness.industrymedicine.medical_treatmentArthrodesisMedial sideProsthesis03 medical and health sciencesFixation (surgical)0302 clinical medicineMedial malleolusmedicine.anatomical_structureFracture fixationMedicine030212 general & internal medicineFemoral componentAnklebusiness
researchProduct

(i) Comminuted patellar fractures

2006

Summary Purpose of review This article reviews current best practice for the diagnosis and treatment of comminuted patellar fractures. Recent findings Patellar fractures make up about 1% of all fractures. As a rule, fractures of the patella are caused by direct trauma to the knee. A transverse fracture is the most common fracture type. Open reduction and internal fixation is the treatment of choice for the majority of displaced patellar fractures. Treatment must achieve anatomic reduction of the articular surface and reestablish the continuity of the extensor mechanism. Tension-band wiring, interfragmentary screw fixation and a combination of cerclage wiring and screw fixation are the most …

musculoskeletal diseasesOrthodonticsmedicine.medical_specialtybusiness.industryTension band wiringmedicine.medical_treatmentDirect traumamusculoskeletal systemmedicine.diseaseSurgerymedicineFracture (geology)Internal fixationOrthopedics and Sports MedicinePatellaDisplacement (orthopedic surgery)Patella fracturebusinessReduction (orthopedic surgery)Current Orthopaedics
researchProduct

Screw‐in‐screw fixation of fragility sacrum fractures provides high stability without loosening—biomechanical evaluation of a new concept

2020

Surgical treatment of fragility sacrum fractures with percutaneous sacroiliac (SI) screw fixation is associated with high failure rates. Turn-out is detected in up to 20% of the patients. The aim of this study was to evaluate a new screw-in-screw implant prototype for fragility sacrum fracture fixation. Twenty-seven artificial hemipelvises were assigned to three groups (n = 9) for instrumentation of an SI screw, the new screw-in-screw implant prototype, ora transsacral screw. Before implantation, a vertical osteotomy was set in zone 1 after Denis. All specimens were biomechanically tested to failure in upright position. Validated setup and test protocol were used for complex axial and torsi…

musculoskeletal diseasesSacrumMaterials sciencePercutaneousmedicine.medical_treatmentBone Screws0206 medical engineering02 engineering and technologyOsteotomyPelvisScrew fixationFracture Fixation InternalFractures Bone03 medical and health sciences0302 clinical medicineFragilitymedicineHumansOrthopedics and Sports MedicinePelvis030203 arthritis & rheumatologyOrthodonticsX-Raysequipment and suppliesmusculoskeletal systemSacrum020601 biomedical engineeringBiomechanical PhenomenaOsteotomyRadiographysurgical procedures operativemedicine.anatomical_structureSpinal FracturesStress MechanicalImplantTest protocolJournal of Orthopaedic Research
researchProduct

A new tool to improve pedicle screw placement accuracy in navigated spine surgery: A monocentric study

2021

Objective Navigated instrumented spine surgery is burden by a low but significant screw mispositioning risks, respectively, for the 2D imaging system from 15 to 40% and, for the 3D imaging system, ranging from 4.1 to 11.5%. The primary objective of this study was to demonstrate the efficacy of a new "screw-like" tool in order to further decrease pedicle screws mispositioning rate during vertebral navigated spine surgery. Materials and methods Between January and June 2019 an initial case series of 18 patients were enrolled. All patients underwent a pedicle screw fixation, both in thoracic (Th10-Th12) and lumbosacral (L1-S1) spine, using O-arm (Medtronic Navigation, Louisville, Colorado) and…

musculoskeletal diseasesmedicine.medical_specialty03 medical and health sciences0302 clinical medicineSpine surgeryImaging Three-DimensionalPedicle ScrewsMedicineHumansPedicle screw fixationPedicle screwNeuronavigationbusiness.industryNavigation systemmusculoskeletal systemSpineSurgerySurgery Computer-Assisted030220 oncology & carcinogenesisEquipment and suppliesSurgeryNeurosurgical proceduresNeurology (clinical)businessTomography X-Ray Computed030217 neurology & neurosurgeryLumbosacral joint
researchProduct

Reaction of the bone structure to methotrexate-Palacos flow y. Experimental investigations in animals.

1989

With the combined osteosynthesis of pathological fractures in association with tumors and/or metastases in mind, E. Merck (Darmstadt, FRG) developed a bone cement containing a cytostatic agent, methotrexate-Palacos flow y (MTX-Pf). The animal-experimental study presented here investigates the tolerability of MTX-Pf in the femurs of rabbits with lateral comparison. In these investigations we used both the concentration of 0.63% MTX, as is currently used in standard clinical surgery, as well as a much higher concentration of 2.5% MTX. The histological sections were investigated using microradiographic methods and provided no indication of any significant differences between the femora with th…

musculoskeletal diseasesmedicine.medical_specialtyBone and BonesFractures BoneMedicineAnimalsOrthopedics and Sports Medicineskin and connective tissue diseasesWound HealingOsteosynthesisbusiness.industryBone CementsGeneral MedicineBone cementSurgeryFracture Fixation IntramedullaryMethotrexateTolerabilityOrthopedic surgerySurgeryMethotrexateRabbitsPathological fracturesbusinessBone structuremedicine.drugArchives of orthopaedic and trauma surgery
researchProduct