Experimental characterization of series arc faults in AC and DC electrical circuits
2014
This paper presents an experimental characterization of the arc fault phenomenon, for both AC and DC systems, focusing the attention on series arcs. The aim of the study is to find some current characteristics, which can be significant for the purpose of arc detection. The arcing current signal is analyzed in both time and frequency domain. For the AC analysis, the test conditions are chosen in accordance with the “unwanted tripping tests” and the “operation inhibition tests” reported in the Standard UL 1699. The DC study is carried out on the currents waveforms acquired during some on-field tests on a PV plant. Starting from the study herein presented, the authors have found that is it pos…
Diagnosis of mechanical unbalance for double cage induction motor load in time-varying conditions based on motor vibration signature analysis
2013
This paper investigates the detectability of mechanical unbalance in double cage induction motor load using motor vibration signature analysis technique. Rotor imbalances induce specific harmonic components in electrical, electromagnetical, and mechanical quantities. Harmonic components characteristic of this category of rotor faults, issued from vibration signals analysis, are closely related to rotating speed of the rotor, which complicates its detection under non-stationary operating conditions of the motor. Firstly, experimental results were performed first under healthy and mechanical load unbalance cases, for different load levels under steady-state operating conditions to evaluate th…
Control of solid-state fault current limiter for DG-integrated distribution systems
2017
Fault current limier (FCL) is a device that limits the system current under fault conditions without disconnecting the system and affecting the power system protection components such as circuit breakers. Many types of FCLs have been proposed to limit the magnitude of the fault current. Solid-state fault current limiters (SSFCLs) can limit the peak value of the fault current by applying several methods, such as controlling the system impedance or controlling the voltage that appears across the fault. In this paper, a new control scheme for the SSFCL circuit is presented. The control method is based on controlling the duty cycle of solid state switches to control the rms value of the system …
Current and Voltage Behaviour During a Fault in a HV/MV System: Methods and Measurements
2015
When a single line to ground fault happens on the MV side of a HV/MV system, only a small portion of the fault current is injected into the ground by the ground-grid of the faulty substation. In fact the fault current is distributed between grounding electrodes and MV cables sheaths. In systems with isolated neutral or with resonant earthing this may be sufficient to provide safety from electric shock. Experimental measurements were performed on a real MV distribution network: a real single line to ground fault was made and fault currents were measured in the faulty substation and in four neighbouring substations. In this paper the problem of fault current distribution is introduced, the te…
Flexible power converters for the fault tolerant operation of Micro-Grids
2010
The progressive penetration level of Distributed Generation (DG) is destined to cause deep changes in the existing distribution networks no longer considered as passive terminations of the whole electrical system. A possible solution is the realization of small networks, namely the Micro-Grids, reproducing in themselves the structure of the main production and distribution of the electrical energy system. In order to gain an adequate reliability level of the microgrids the individuation and the management of the faults with the goal of maintaining the micro-grid operation (fault tolerant operation) is quite important. In the present paper flexible power converters and a companion control al…
Closed-loop bandwidth impact on MVSA for rotor broken bar diagnosis in IRFOC double squirrel cage induction motor drives
2013
This paper investigates the detectability of rotor broken bars in indirect rotor flux oriented control (IRFOC) for variable speed double cage induction motor drives, using vibration signature analysis techniques. The Impact of the closed loop control system cannot be neglected when the detection of rotor asymmetries in the machine is based on the signature analysis of electrical or mechanical variables. Therefore, the investigation of rotor fault components for different bandwidths of closed-loop regulators is necessary to evaluate its relevance in the above listed variables. This paper investigates the impact of the control system on relevance of the fault components computed from axial an…
Nature and origin of fault-controlled fluid seepage across the Maltese Islands
2018
The Maltese Islands are intersected by two major fault systems associated with two diverse rifting episodes affect the islands. The first and most widespread system is Early Miocene to mid-Pliocene in age, and consists of faults that are orientated ENE-WSW. The most distinct of these faults is the Great Fault (known also as the Victoria Lines Fault). The younger system of faults (Late Miocene-Early Pliocene) is still active and consists of faults striking NW to SE that often cross-cut the first generation of faults. The most extensive of these faults is the Maghlaq Fault, located along the southern coastline of the Maltese Islands.
FUZZY RISK ANALYSIS OF A MODERN γ-RAY INDUSTRIAL IRRADIATOR
2011
Fuzzy fault tree analyses were used to investigate accident scenarios that involve radiological exposure to operators working in industrial γ-ray irradiation facilities. The HEART method, a first generation human reliability analysis method, was used to evaluate the probability of adverse human error in these analyses. This technique was modified on the basis of fuzzy set theory to more directly take into account the uncertainties in the error-promoting factors on which the methodology is based. Moreover, with regard to some identified accident scenarios, fuzzy radiological exposure risk, expressed in terms of potential annual death, was evaluated. The calculated fuzzy risks for the examine…
Getting insights into the behavior of variable speed direct expansion air conditioning systems under faulty operating conditions
2019
Direct expansion air conditioning systems, such as rooftop units, are widely adopted in small and medium scale commercial buildings. In order to increase the energy performance of these systems during part-load operation, variable-speed compressors and fans have been adopted in the last two decades. However, profitable energy saving could be achieved not only by optimizing the design and the control of these systems, but also by scheduling a proper maintenance strategy. In fact, if not properly maintained, no benefits would be achieved even when more sophisticated systems are adopted. In order to support plant owners in scheduling cost-effective maintenance program, Fault Detection and Diag…
Assessing the Robustness of Thermoeconomic Diagnosis of Fouled Evaporators: Sensitivity Analysis of the Exergetic Performance of Direct Expansion Coi…
2016
Thermoeconomic diagnosis of refrigeration systems is a pioneering approach to the diagnosis of malfunctions, which has been recently proven to achieve good performances for the detection of specific faults. Being an exergy-based diagnostic technique, its performance is influenced by the trends of exergy functions in the “design” and “abnormal” conditions. In this paper the sensitivity of performance of thermoeconomic diagnosis in detecting a fouled direct expansion coil and quantifying the additional consumption it induces is investigated; this fault is critical due to the simultaneous air cooling and dehumidification occurring in the coil, that induce variations in both the chemical and th…