Search results for " Fourier Transform"

showing 10 items of 431 documents

Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …

2009

A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…

ChromatographyAbsorption spectroscopyChemistryReference data (financial markets)Analytical chemistryInfrared spectroscopyFourier transform spectroscopyAnalytical ChemistryNitrophenolschemistry.chemical_compoundSpectroscopy Fourier Transform InfraredBackground Correction MethodFourier transform infrared spectroscopySpectroscopyAcetonitrileAlgorithmsChromatography LiquidTalanta
researchProduct

Partial least squares attenuated total reflectance IR spectroscopy versus chromatography: the greener method

2012

Method election is a complex task that must be done carefully in order to ensure the capability of analytical methodologies to provide appropriate data for problem solving. This is a real challenge in all fields, but especially with bioanalysis, which in many cases involves the need to do a large number of determinations in complex

ChromatographyBioanalysisChromatographyChemistryClinical BiochemistryInfrared spectroscopyGreen Chemistry TechnologyGeneral MedicineAnalytical ChemistryMedical Laboratory TechnologyAttenuated total reflectionSpectroscopy Fourier Transform InfraredPartial least squares regressionLeast-Squares AnalysisGeneral Pharmacology Toxicology and PharmaceuticsBioanalysis
researchProduct

Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry

2007

An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…

ChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryInfrared spectroscopyGeneral MedicineReference StandardsMass spectrometryBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryMatrix (chemical analysis)ChemometricsAbsorbanceDiuronSpectroscopy Fourier Transform InfraredAtrazineFourier transform infrared spectroscopyChromatography LiquidJournal of Chromatography A
researchProduct

Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.

2007

The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…

ChromatographyDiffuse reflectance infrared fourier transformChemistryAttenuated total reflectionDirect methodPartial least squares regressionCalibrationAnalytical chemistryInfrared spectroscopyFourier transform infrared spectroscopyFourier transform spectroscopyAnalytical ChemistryTalanta
researchProduct

Infrared biospectroscopy for a fast qualitative evaluation of sample preparation in metabolomics.

2014

Liquid chromatography-mass spectrometry (LC-MS) has been increasingly used in biomedicine to study the dynamic metabolomic responses of biological systems under different physiological or pathological conditions. To obtain an integrated snapshot of the system, metabolomic methods in biomedicine typically analyze biofluids (e.g. plasma) that require clean-up before being injected into LC-MS systems. However, high resolution LC-MS is costly in terms of resources required for sample and data analysis and care must be taken to prevent chemical (e.g. ion suppression) or statistical artifacts. Because of that, the effect of sample preparation on the metabolomic profile during metabolomic method d…

ChromatographyPlasma samplesChemistryPlasma compositionIon suppression in liquid chromatography–mass spectrometryBlood ProteinsMass spectrometryMethod developmentMass SpectrometryAnalytical ChemistryMice Inbred C57BLExploratory data analysisMetabolomicsSpectroscopy Fourier Transform InfraredAnimalsMetabolomicsSample preparationFemaleChromatography LiquidTalanta
researchProduct

Determination of lecithin and soybean oil in dietary supplements using partial least squares-Fourier transform infrared spectroscopy.

2008

Lecithin and soybean oil in dietary supplements were determined by Fourier transform infrared spectrometry transmission measurements in dichloromethane in combination with a partial least squares (PLS) regression. Two different PLS models were developed, using 16 synthetic mixtures of analytes in dichloromethane, making measurements in the spectral range from 931.8 to 1252.3 cm(-1) for lecithin and from 911.4 to 1246.9 cm(-1) and 1695.3 to 1774.5 cm(-1) for soybean oil. Seven products from the Spanish market with lecithin concentrations between 21.1% and 99.1% and soybean oil concentrations between 0% and 37.2% were analyzed by the proposed method and the data was compared to a chromatograp…

Chromatographyfood.ingredientChemistryfood and beveragesLecithinFourier transform spectroscopySoybean oilAnalytical ChemistrySoybean Oilchemistry.chemical_compoundfoodPartial least squares regressionCalibrationDietary SupplementsLecithinsSpectroscopy Fourier Transform InfraredFourier transform infrared spectrometryFourier transform infrared spectroscopyLeast-Squares AnalysisDichloromethane
researchProduct

The chemistry of Cr(VI) adsorption on to poly(p-phenylenediamine) adsorbent

2019

Abstract Water pollution due to industrial processes has necessitated and spurred robust research into the development of adsorbent materials for remediation. Polyphenylenediamines (PPD) have attracted significant attention because of their dual cationic and redox properties. They are able to reduce Cr(VI) to Cr(III) in solution. Interrogation of the chemical processes involved in the Cr(VI) adsorption on para-PPD was primarily by X-ray photoelectron spectroscopy (XPS) and Fourier transform infrared (FT-IR) spectroscopy. It was confirmed that the underlying oxidation of the amino groups to imines during the reduction of Cr(VI) to Cr(III) was irreversible. This process occurred at both acidi…

ChromiumEnvironmental Engineering02 engineering and technologyPhenylenediamines010402 general chemistry01 natural sciencesRedoxWater PurificationAdsorptionX-ray photoelectron spectroscopySpectroscopy Fourier Transform InfraredChelationSpectroscopyWater Science and Technologychemistry.chemical_classificationAqueous solutionCationic polymerizationPolymerHydrogen-Ion Concentration021001 nanoscience & nanotechnology0104 chemical scienceschemistryAdsorption0210 nano-technologyWater Pollutants ChemicalNuclear chemistryWater Science and Technology
researchProduct

Premature aging in bone of fish from a highly polluted marine area

2015

Fish species have attracted considerable interest in studies assessing biological responses to environmental contaminants. In this study, the attention has been focussed on fishbone of selected fish species from a highly polluted marine area, Augusta Bay (Italy, Central Mediterranean) to evaluate if toxicant elements had an effect on the mineralogical structure of bones, although macroscopic deformations were not evident. In particular, an attempt was made to evaluate if bone mineral features, such as crystallinity, mineral maturity and carbonate/phosphate mineral content, determined by XR-Diffraction and FT-IR Spectroscopy, suffered negative effects due to trace element levels in fishbone,…

ChromiumMediterranean climatePremature agingAugusta Bay (Italy)XRDMineralogyAquatic ScienceOceanographyBone and Boneschemistry.chemical_compoundCalcification PhysiologicX-Ray DiffractionSpectroscopy Fourier Transform InfraredAnimalsBone mineralMaturity (geology)Body WeightWater PollutionFishesTrace elementCrystalline structure fishboneReproducibility of ResultsAging PrematureMercuryContaminationPollutionHydroxylapatiteFT-IRItalychemistryEnvironmental chemistryTrace elementEnvironmental scienceCarbonateBay
researchProduct

Glucagon fibril polymorphism reflects differences in protofilament backbone structure

2010

Amyloid fibrils formed by the 29-residue peptide hormone glucagon at different concentrations have strikingly different morphologies when observed by transmission electron microscopy. Fibrils formed at low concentration (0.25 mg/mL) consist of two or more protofilaments with a regular twist, while fibrils at high concentration (8 mg/mL) consist of two straight protofilaments. Here, we explore the structural differences underlying glucagon polymorphism using proteolytic degradation, linear and circular dichroism, Fourier transform infrared spectroscopy (FTIR), and X-ray fiber diffraction. Morphological differences are perpetuated at all structural levels, indicating that the two fibril class…

Circular dichroismAmyloidProtein FoldingChemistryProtein StabilityCircular DichroismProteolytic enzymesmacromolecular substancesLinear dichroismFibrilGlucagonSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Protein Structure SecondaryCrystallographyX-Ray DiffractionStructural BiologySpectroscopy Fourier Transform InfraredSide chainFourier transform infrared spectroscopyProtein MultimerizationFiber diffractionMolecular BiologyProtein secondary structurePolymorphism Amyloid Glucagon Structural changesPeptide Hydrolases
researchProduct

Cytotoxic hydrophilic iminophosphorane coordination compounds of d8 metals. Studies of their interactions with DNA and HSA

2012

The synthesis and characterization of a new water-soluble N,N-chelating iminophosphorane ligand TPAN-C(O)-2-NC(5)H(4) (N,N-IM) (1) and its d(8) (Au(III), Pd(II) and Pt(II)) coordination complexes are reported. The structures of cationic [AuCl(2)(N,N-IM)]ClO(4) (2) and neutral [MCl(2)(N,N-IM)] M=Pd (3), Pt(4) complexes were determined by X-ray diffraction studies or by means of density-functional calculations. While the Pd and Pt compounds are stable in mixtures of DMSO/H(2)O over 4 days, the gold derivative (2) decomposes quickly to TPAO and previously reported neutral gold(III) compound [AuCl(2)(N,N-H)] 5 (containing the chelating N,N-fragment HN-C(O)-2-NC(5)H(4)). The cytotoxicities of co…

Circular dichroismMagnetic Resonance SpectroscopyStereochemistryPhosphoranesAntineoplastic AgentsBiochemistryMedicinal chemistryArticleCoordination complexInorganic ChemistryX-Ray DiffractionCell Line TumorSpectroscopy Fourier Transform InfraredmedicineHumansChelationSerum Albuminchemistry.chemical_classificationCisplatinLigandCircular DichroismIsothermal titration calorimetryDNANuclear magnetic resonance spectroscopyHuman serum albuminSpectrometry FluorescencechemistryMetalsCisplatinHydrophobic and Hydrophilic Interactionsmedicine.drugJournal of Inorganic Biochemistry
researchProduct