Search results for " Hearing loss"
showing 10 items of 105 documents
Initial experience with the Sophono Alpha 1 osseointegrated implant.
2013
In the last several years, bone anchored hearing aids have proven to be useful in treating conductive and mixed unilateral or bilateral hearing loss, as well as for sensorineural unilateral hearing loss. The Sophono Alpha 1 model has the advantage of not requiring an abutment, with it being coupled by magnetism instead. We report the cases of 3 infants with congenital malformations of external and middle ear. Audiometry showed conductive hearing loss. All 3 patients were implanted with Alpha 1 model (Sophono). Patients evolved satisfactorily. After 30 days we applied the processor and the control audiometry showed a marked improvement of hearing thresholds, although without a complete closu…
An experimental comparative study of dexamethasone, melatonin and tacrolimus in noise-induced hearing loss.
2008
The calcineurin inhibitor tacrolimus (TCR) and the pineal gland hormone and antioxidant melatonin (MLT) have been shown to possess otoprotective properties against noise-induced hearing loss (NIHL). In contrast, dexamethasone (DXM) was not effective as an otoprotective agent against NIHL. Further studies are needed to understand the exact molecular mechanisms involved.Exposure to noise pollution and use of audio devices for long periods of time at high volume is known to cause hearing loss or NIHL. Our goal was to evaluate the effectiveness of various known compounds such as the anti-inflammatory DXM, the antioxidant MLT and the immunosuppressant TCR against NIHL.Thirty-two Wistar rats were…
First Experiences With the Ponto⢢ SuperPower Osseointegrated Device
2018
Osseointegrated hearing devices Power and SuperPower present indications for bone thresholds of 55 and 65 dB respectively. We conducted a prospective observational study of a series of six cases with mixed hearing loss for whom implantation of the DAO Ponto™ Super-Power was performed. Tonal and verbal evaluations without and with background noise (HINTS) were performed prior to implantation and six months after adaptation. All the participants showed improvement in tonal and verbal results, varying according to the degree of contralateral hearing loss. The verbal results with background noise were noteworthy, where most of the patients obtained a signal-to-noise ratio between 2 and 4 dB. Th…
Prelingual sensorineural hearing loss and infants at risk: Western Sicily report.
2013
Objective: To evaluate independent etiologic factor associated with sensorineural hearing loss (SNHL) in newborn at risk; to study the role of their interaction especially in NICU infants who present often multiple risk factors for SNHL. Methods: The main risk factors for SNHL reported by JCIH 2007 were evaluated on 508 infant at risk ranging from 4 to 20 weeks of life, transferred to the Audiology Department of Palermo from the main births centers of Western Sicily. After a global audiological assessment, performed with TEOAE, tympanometry and ABR, the prevalence and the effect of risk factors was statistically studied through univariate and multivariate analysis on the total population (n…
The Jervell and Lange-Nielsen syndrome.
1991
Deafness and electrocardiographic changes (prolongation of the Q-T interval and inversion of the T wave) with a clinical picture of syncopal attacks and sudden death, were described as a distinct syndrome by Jervell and Lange-Nielsen in 1957. The syndrome is inherited as an autosomal recessive trait. In this study, all the cases reported since 1957 and their proposed prevalence are reviewed. The authors describe the 4 cases they have studied, all of which presented congenital sensorineural hearing loss and electrocardiographic changes characteristic of the syndrome. The relatively high number of cases they have encountered casts doubt on literature that states that the syndrome occurs more …
Cochlear implant complications and failures
2010
Abstract Introduction Cochlear implantation is a relatively safe surgery performed on profound bilateral hearing loss patients. Its surgical indications have increased and the age of implantation has decreased over the last years. As with any other surgery, it presents complications; device failure is one of the most important, given its potential risk for the need to explant and reimplant the device. Objective To evaluate cochlear implant complications, determine possible causes and discuss medical and surgical management. Material and methods A retrospective study of cochlear implants was performed. A total of 246 implants over an eleven-year period were evaluated. The sample consisted of…
Comparative Study Between Unilateral and Bilateral Cochlear Implantation in Children of 1 and 2 Years of Age
2016
Abstract Introduction The studies that have evaluated the effectiveness of bilateral cochlear implantation in children suggest an improvement in hearing about sound localisation and speech discrimination. In this paper we show the differences in audio-linguistic achievements with early bilateral cochlear implantation versus unilateral, and differences between simultaneous and sequential bilateral implantation. Material and methods We present 88 children with bilateral profound sensorineural hearing loss, treated with bilateral cochlear implantation in 32 cases and unilateral in 56 cases, during the first 12 months (27 children) of life and between 12 and 24 months (61 children). We conducte…
Evolution of otosclerosis to cochlear implantation.
2011
Abstract Introduction Otosclerosis is an osteodystrophy of the labyrinthine capsule producing conductive hearing loss. If the process invades the cochlea, a sensorineural hearing loss usually takes place. The cochlear implant is a good alternative in these patients. Objective To ascertain the behaviour of cochlear implantation (CI) in otosclerosis. Material and methods We reviewed a database of 250 patients who underwent CI, performing a retrospective study of 13 patients with clinical, audiological and/or imaging findings of bilateral otosclerosis. The 26 ears were studied as to their natural history, previous surgeries, evolution to profound hearing loss, computed tomography (CT) images, …
Decreased postural control in people with moderate hearing loss
2018
Balance is a complex process that involves multiple sensory integrations. The auditory, visual, and vestibular systems are the main contributors. Hearing loss or hearing impairment may induce inappropriate postural strategies that could affect balance and therefore increase the risk of falling. The aim of this study was to understand whether hearing loss could influence balance, cervical posture, and muscle activation in the cervical region. Thirteen patients (61 ± 13 years; 161.8 ± 11.0 cm; 70.5 ± 15.9 kg) with moderate hearing loss (Right ear −60 ± 21 dB; Left ear −61 ± 24 dB) underwent: an audiometric examination, a postural examination (with open and closed eyes) through a stabilometric…
Bacterial Cytolysin Perturbs Round Window Membrane Permeability Barrier In Vivo: Possible Cause of Sensorineural Hearing Loss in Acute Otitis Media
1998
ABSTRACT The passage of radioiodinated streptolysin-O (SLO) and albumin through the round window membrane (RWM) was studied in vivo. When applied to the middle ear, SLO became quantitatively entrapped in this compartment and no passage to the cochlea occurred. However, flux of radioiodinated albumin through the toxin-damaged RWM was observed. We propose that the passage of noxious macromolecules, such as proteases, from a purulent middle-ear effusion may be facilitated by pore-forming toxins, resulting in cochlear damage and sensorineural hearing loss.