Search results for " High pressure liquid"

showing 10 items of 705 documents

Synthesis, structure and properties of N-acetylated derivatives of methyl 5-amino-1H-[1,2,4]triazole-3-carboxylate.

2004

Methyl 5-amino-1H-[1,2,4]triazole-3-carboxylate hydrochloride (1). and free ester (2). were obtained and 2 was reacted with Ac(2)O to give the acetylated products 3-6. Compounds 1-6 were studied using HPLC, GC-MS, FTIR and multinuclear NMR spectroscopy, including the cross-polarisation magic angle spinning (CPMAS) technique. The results of the acetylation of 2 were compared to those of the acetylation of 5-amino-1H-[1,2,4]triazole, and for 2 a significant decrease in the susceptibility to acetylation was found. The reaction of 2 with Ac(2)O at 20 degrees C, regardless of the amount and the concentration of the latter, including neat Ac(2)O, proceeds fully regioselectively and leads to one p…

Molecular StructureStereochemistryHydrochlorideTriazole124-TriazoleAcetylationEstersGeneral ChemistryGeneral MedicineNuclear magnetic resonance spectroscopyTriazolesMedicinal chemistryGas Chromatography-Mass SpectrometryAcylationchemistry.chemical_compoundHydrolysischemistryAcetylationDrug DiscoverySpectroscopy Fourier Transform InfraredMagic angle spinningCarboxylateChromatography High Pressure LiquidChemicalpharmaceutical bulletin
researchProduct

Ultra-short ion-exchange columns for fast charge variants analysis of therapeutic proteins

2021

Abstract The purpose of this work was to study the potential of recently developed ultra-short column hardware for ion exchange chromatography (IEX). Various prototype and commercial columns having lengths of 5, 10, 15, 20 and 50 mm and packed with non-porous 3 µm particles were systematically compared. Both pH and salt gradient modes of elution were evaluated. Similarly, what has been previously reported for reversed phase liquid chromatography (RPLC) mode, an “on-off” retention mechanism was observed in IEX for therapeutic proteins and their fragments (25–150 kDa range). Because of the non-porous nature of the IEX packing material, the column porosity was relatively low (e = 0.42) and the…

Monoclonal antibodyChromatography Reverse-PhaseRange (particle radiation)ddc:615ChromatographyIon exchangeChemistryElutionOrganic ChemistryIon chromatographyIon-exchange chromatographyGeneral MedicineReversed-phase chromatographyChromatography Ion ExchangeBiochemistryUltra-short columnExtra-column volumeAnalytical ChemistryVolume (thermodynamics)PeekPorosityFast separationPorosityChromatography High Pressure Liquid
researchProduct

Origin and correction of the deviations in retention times at increasing flow rate with Chromolith columns.

2010

Chromoliths can be used at flow rates beyond those feasible for conventional microparticulate packed columns. Ideally, the plots of the retention time versus the inverse of delivered flow rate should exhibit y-intercept of zero. However, significant positive deviations correlating with the solute polarity were observed for several compounds chromatographed with a Chromolith column, owing to the increased system pressure. Consequently, the dead time marker exhibits a smaller deviation, making the retention factors depend on the flow rate. Chromoliths are made of a silica-based monolith encapsulated within a PEEK tube, and should suffer larger stress with pressure than stainless steel columns…

Monolithic HPLC columnAcetonitrilesPolymersAnalytical chemistryBiochemistryAnalytical ChemistryPolyethylene GlycolsStress (mechanics)PropanolaminesBenzophenonesPeekMonolithChromatography High Pressure Liquidgeographygeography.geographical_feature_categoryChromatographyChemistryOrganic ChemistryGeneral MedicineDead timeKetonesSilicon DioxideVolumetric flow rateVolume (thermodynamics)Linear ModelsBar (unit)Journal of chromatography. A
researchProduct

Flow-through pore characteristics of monolithic silicas and their impact on column performance in high-performance liquid chromatography

2008

Abstract In order to elucidate the role of the flow-through characteristics with regard to the column performance in high-performance liquid chromatography (HPLC) native and n -octadecyl bonded monolithic silica rods and columns, respectively of 100 mm length and 4.6 mm ID with mesopores in the range between 10 and 25 nm and macropores in the range between 0.7 and 6.0 μm were examined by mercury intrusion/extrusion, scanning electron microscopy, image analysis and permeability. The obtained data of the flow-through pore sizes and porosity values as well as surface-to-volume ratio of the stationary phase skeleton enabled to predict their influence to the chromatographic separation efficiency…

Monolithic HPLC columnChromatographyChemistryScanning electron microscopeSilica gelOrganic ChemistryAnalytical chemistryGeneral MedicinePorosimetryReversed-phase chromatographySilicon DioxideBiochemistryAnalytical ChemistrySeparation processchemistry.chemical_compoundMicroscopy Electron ScanningPorosityMesoporous materialPorosityChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

3D printed fluidic platform with in-situ covalently immobilized polymer monolithic column for automatic solid-phase extraction

2020

Abstract In this work, 3D stereolithographic printing is proposed for the first time for the fabrication of fluidic devices aimed at in-situ covalent immobilization of polymer monolithic columns. Integration in advanced flow injection systems capitalized upon programmable flow was realized for fully automatic solid-phase extraction (SPE) and clean-up procedures as a ‘front-end’ to on-line liquid chromatography. The as-fabricated 3D-printed extraction column devices were designed to tolerate the pressure drop of forward-flow fluidic systems when handling large sample volumes as demonstrated by the determination of anti-microbial agents, plastic additives and monomers as models of emerging co…

Monolithic HPLC columnPolymersSurface Properties02 engineering and technology01 natural sciencesBiochemistryAnalytical ChemistryAutomationchemistry.chemical_compoundHumansEnvironmental ChemistryFluidicsSolid phase extractionParticle SizeMonolithSalivaChromatography High Pressure LiquidSpectroscopychemistry.chemical_classificationgeographygeography.geographical_feature_categoryMolecular StructureMethylparabenSolid Phase Extraction010401 analytical chemistryExtraction (chemistry)Polymer021001 nanoscience & nanotechnologyTriclosan0104 chemical scienceschemistryChemical engineeringColloidal goldPrinting Three-Dimensional0210 nano-technologyAnalytica Chimica Acta
researchProduct

Towards unsupervised analysis of second-order chromatographic data: automated selection of number of components in multivariate curve-resolution meth…

2007

A method to apply multivariate curve-resolution unattendedly is presented. The algorithm is suitable to perform deconvolution of two-way data (e.g. retrieving the individual elution profiles and spectra of co-eluting compounds from signals obtained from a chromatograph equipped with multiple-channel detection: LC-DAD or GC-MS). The method is especially adequate to achieve the advantages of deconvolution approaches when huge amounts of data are present and manual application of multivariate techniques is too time-consuming. The philosophy of the algorithm is to mimic the reactions of an expert user when applying the orthogonal projection approach--multivariate curve-resolution techniques. Ba…

Multivariate statisticsChromatographybusiness.industryChemistryOrganic ChemistryAutocorrelationOrthographic projectionGeneral MedicineBiochemistryAutomationData matrix (multivariate statistics)Analytical ChemistryChemometricsAutomationMultivariate AnalysisDeconvolutionbusinessSelection (genetic algorithm)Chromatography High Pressure LiquidJournal of chromatography. A
researchProduct

Background Correction and Multivariate Curve Resolution of Online Liquid Chromatography with Infrared Spectrometric Detection

2011

J.K. acknowledges the “V Segles” grant provided by the University of Valencia to carry out this study. Authors acknowledge the financial support of Ministerio de Educación y Ciencia (Projects AGL2007-64567 and CTQ2008-05719/BQU) and Conselleria d'Educació de la Generalitat Valenciana (Project PROMETEO 2010-055).

Multivariate statisticsPrincipal Component AnalysisChromatographySpectrophotometry InfraredInfraredChemistryAnalytical chemistrySubtractionPhase (waves)CarbohydratesSignalAnalytical ChemistryNitrophenolsNitrophenolchemistry.chemical_compoundPrincipal component analysisLeast-Squares AnalysisAbsorption (electromagnetic radiation)AlgorithmsChromatography High Pressure LiquidSoftware
researchProduct

Measurement of microalbuminuria – what the nephrologist should know

2005

Nephrologymedicine.medical_specialtymedicine.medical_treatmentMEDLINEAlbuminsInternal medicineDiabetes mellitusmedicineAlbuminuriaHumansRisk factorChromatography High Pressure LiquidTransplantationProteinuriabusiness.industryPrognosismedicine.diseaseSurgeryNephrologyPractice Guidelines as TopicMicroalbuminuriaHemodialysismedicine.symptombusinessBiomarkersKidney diseaseNephrology Dialysis Transplantation
researchProduct

Lipid nanocarriers containing sorafenib inhibit colonies formation in human hepatocarcinoma cells

2015

Here, the potential of two nanostructured lipid carriers (NLC) for controlled release of sorafenib was evaluated. The obtained systems showed characteristics suitable as drug delivery systems for the treatment of hepatocellular carcinoma (HCC) through parenteral administration. The use of a mixture between a solid lipid (tripalmitin) with a liquid lipid (Captex 355 EP/NF or Miglyol 812) to prepare NLC systems could give a higher drug loading capacity and a longer term stability during storage than that obtained by using only solid lipids. The obtained nanoparticles showed a nanometer size and high negative zeta potential values. Scansion electron microscopy (SEM) of the sorafenib loaded NLC…

NiacinamideSorafenibDrugCell Survivalmedia_common.quotation_subjectnanostructured lipid carriersPharmaceutical ScienceAntineoplastic AgentsPharmacologyHemolysischemistry.chemical_compoundNanostructured lipid carriers Sorafenib Drug release Angiogenesis inhibitor HepatocarcinomamedicineZeta potentialHumansParticle SizeChromatography High Pressure LiquidTriglyceridesdrug releasemedia_commonDrug CarriersPhenylurea CompoundsHep G2 Cellsmedicine.diseaseLipidsControlled releasedigestive system diseasesIn vitroDrug Liberationangiogenesis inhibitorchemistryhepatocarcinomaSettore CHIM/09 - Farmaceutico Tecnologico ApplicativoDelayed-Action PreparationsHepatocellular carcinomaTripalmitinDrug deliveryMicroscopy Electron ScanningNanoparticlessorafenibCaprylatesmedicine.drug
researchProduct

Analysis of Nicotine and Its Oxidation Products in Nicotine Chewing Gum by a Molecularly Imprinted Solid-Phase Extraction

2000

Chromatographic stationary phases showing exceptional selectivity for nicotine can be prepared by the technique of molecular imprinting. Such phases were used in the search for a rapid cleanup step for nicotine and some of its oxidation products in chewing gum formulations. Thus, using an organic mobile phase, the nicotine analytes from chewing gums dissolved in nonpolar solvent were retained, whereas the nonpolar matrix eluted close to the void peak. A subsequent switch to an acidic mobile phase resulted in elution of the analytes as one sharp peak. Due to weak binding of the less basic oxidation products, other imprinted polymers were tested, and the solid-phase extraction procedure was o…

NicotineChromatographyNicotine Chewing GumPolymersChemistryElutionExtraction (chemistry)Reversed-phase chromatographyAnalytical ChemistryChewing GumMatrix (chemical analysis)SolventSolid phase extractionMolecular imprintingChromatography High Pressure LiquidAnalytical Chemistry
researchProduct