Search results for " INTERPRETATION"

showing 10 items of 555 documents

Impact of the Tiloop Bra mesh in CT images and dose delivery in breast radiotherapy

2012

A new titanized breast mesh, TiLOOP Bra, is currently available for implantation in patients who require radiotherapy. The purpose of this work is to study the dosimetric effect of the presence of a TiLOOP Bra mesh on breast radiation treatment and radiographic imaging. The dosimetric effects have been measured for three X‐ray energies: 1.25 MeV, 6 MV and 18 MV, using radiochromic films placed at three different depths. These depths are representative of mesh location in breast during the radiotherapy treatment and hence, are of interest in this study. In order to assess the disturbance in a radiographic image, different computed tomographic (CT) studies of the mesh have been performed. The…

medicine.medical_specialtyBreast Implantsmedicine.medical_treatmentRadiographyBreast Neoplasmsmetallic artifactprothesesHounsfield scalemedicineRadiation Oncology PhysicsHumansDosimetryRadiology Nuclear Medicine and imagingInstrumentationtitanizationDose deliveryRadiationPhantoms Imagingbusiness.industryRadiotherapy Planning Computer-AssistedRadiotherapy DosageSurgical MeshRadiation therapySurgical meshmeshAbsorbed doseRadiographic Image Interpretation Computer-AssistedFemaleRadiologyTomographyTomography X-Ray ComputedbusinessNuclear medicine
researchProduct

Advanced Protocol for Three-Dimensional Transesophageal Echocardiography Guidance Implementing Real-Time Multiplanar Reconstruction for Transcatheter…

2019

Transcatheter direct annuloplasty has been introduced as a novel interventional treatment option for severe mitral valve regurgitation. Until now, only one direct annuloplasty device (Edwards Cardioband) has been commercially available, being implanted in more than 250 patients worldwide. Yet this procedure poses greater challenges regarding optimal fluoroscopic and echocardiographic guidance compared with edge-to-edge repair: correct localization and orientation of the anchors upon penetration into the fibrous mitral annulus tissue and the basal left ventricular myocardium are preconditions for an optimal result and essential to avoid damage of the neighboring structures (atrioventricular …

medicine.medical_specialtyCardiac CatheterizationMitral Valve AnnuloplastyEchocardiography Three-Dimensional030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingCircumflexCoronary sinusProtocol (science)Interventional treatmentbusiness.industryMitral Valve InsufficiencyMultiplanar reconstructionmedicine.diseaseAtrioventricular nodemedicine.anatomical_structureSurgery Computer-Assistedcardiovascular systemTranscatheter mitral valve repairRadiologyCardiology and Cardiovascular MedicinebusinessMitral valve regurgitationEchocardiography TransesophagealJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography
researchProduct

Computer-assisted interpretation of flow cytometry data in hematology.

1996

A computer program has been developed for computer-assisted diagnosis (including subclassification) of flow cytometry data of acute leukaemias and non-Hodgkin lymphomas by means of artificial intelligence. The knowledge base for the system has been formulatedas semantic networks that describe physiological hematopoiesisas well as the pathological situation (eg., aberrant antigen expression) of hematological disorders. The semantic networks reflect the hierarchy of cells and their occurrence in diseases, the normal and pathological antigen expression patterns of cells, cell maturation, and the frequency of cell populations in normal blood and bone marrow. Using these semantic networks, the d…

medicine.medical_specialtyCellBiophysicsExpert SystemsDiseaseCell MaturationPathology and Forensic MedicineFlow cytometryEndocrinologyAntigenInternal medicineMedicineHumansDiagnosis Computer-AssistedPathologicalHematologyLeukemiamedicine.diagnostic_testbusiness.industryLymphoma Non-HodgkinReproducibility of ResultsCell BiologyHematologyFlow Cytometrymedicine.anatomical_structureData Interpretation StatisticalImmunologyAcute DiseaseBone marrowbusinessCytometry
researchProduct

Primary ciliary dyskinesia assessment by means of optical flow analysis of phase-contrast microscopy images

2014

Primary ciliary dyskinesia implies cilia with defective or total absence of motility, which may result in sinusitis, chronic bronchitis, bronchiectasis and male infertility. Diagnosis can be difficult and is based on an abnormal ciliary beat frequency (CBF) and beat pattern. In this paper, we present a method to determine CBF of isolated cells through the analysis of phase-contrast microscopy images, estimating cilia motion by means of an optical flow algorithm. After having analyzed 28 image sequences (14 with a normal beat pattern and 14 with a dyskinetic pattern), the normal group presented a CBF of 5.2 +/- 1.6 Hz, while the dyskinetic patients presented a 1.9 +/- 0.9 Hz CBF. The cutoff …

medicine.medical_specialtyChronic bronchitisPhase contrast microscopyOptical flowBeat (acoustics)Health InformaticsSensitivity and SpecificityPattern Recognition Automatedlaw.inventionTECNOLOGIA ELECTRONICAPrimary ciliary dyskinesialawOphthalmologyImage Interpretation Computer-AssistedMicroscopymedicineHumansMicroscopy Phase-ContrastRadiology Nuclear Medicine and imagingPrimary ciliary dyskinesiaMicroscopy VideoBronchiectasisRadiological and Ultrasound Technologybusiness.industryCiliumOptical flowActive contoursReproducibility of ResultsAnatomyImage Enhancementmedicine.diseaseComputer Graphics and Computer-Aided DesignCell TrackingSubtraction TechniqueFISICA APLICADABeat frequencyComputer Vision and Pattern RecognitionbusinessMATEMATICA APLICADAAlgorithmsFourier-Mellin transformCiliary Motility Disorders
researchProduct

A Multi-Variate Predictability Framework to Assess Invasive Cardiac Activity and Interactions during Atrial Fibrillation

2017

Objective: This study introduces a predictability framework based on the concept of Granger causality (GC), in order to analyze the activity and interactions between different intracardiac sites during atrial fibrillation (AF). Methods: GC-based interactions were studied using a three-electrode analysis scheme with multi-variate autoregressive models of the involved preprocessed intracardiac signals. The method was evaluated in different scenarios covering simulations of complex atrial activity as well as endocardial signals acquired from patients. Results: The results illustrate the ability of the method to determine atrial rhythm complexity and to track and map propagation during AF. Conc…

medicine.medical_specialtyComputer science0206 medical engineeringAtrial fibrillation (AF)Biomedical EngineeringCardiac activity02 engineering and technology030204 cardiovascular system & hematologyIntracardiac injectionmulti-variate autoregressive (MVAR) modeling03 medical and health sciences0302 clinical medicineHeart Conduction SystemInternal medicineAtrial Fibrillationmultielectrode cathetermedicineHumansComputer SimulationPredictabilityModels Statisticalbusiness.industryBody Surface Potential MappingModels CardiovascularPattern recognitionAtrial fibrillationmedicine.disease020601 biomedical engineeringRandom variateAutoregressive modelData Interpretation Statisticalbipolar electrograms (EGMs)Multivariate AnalysisSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaCardiologyGranger causality (GC)Artificial intelligencebusiness
researchProduct

Calculation of NNTs in RCTs with time-to-event outcomes: A literature review

2008

Abstract Background The number needed to treat (NNT) is a well-known effect measure for reporting the results of clinical trials. In the case of time-to-event outcomes, the calculation of NNTs is more difficult than in the case of binary data. The frequency of using NNTs to report results of randomised controlled trials (RCT) investigating time-to-event outcomes and the adequacy of the applied calculation methods are unknown. Methods We searched in PubMed for RCTs with parallel group design and individual randomisation, published in four frequently cited journals between 2003 and 2005. We evaluated the type of outcome, the frequency of reporting NNTs with corresponding confidence intervals,…

medicine.medical_specialtyEpidemiologyMEDLINEHealth Informaticslaw.inventionRandomized controlled triallawStatisticsConfidence IntervalsHumansMedicineRandomized Controlled Trials as Topiclcsh:R5-920business.industryAbsolute risk reductionConsolidated Standards of Reporting TrialsConfidence intervalClinical trialSample size determinationData Interpretation StatisticalSample SizeNumber needed to treatPhysical therapylcsh:Medicine (General)businessResearch ArticleBMC Medical Research Methodology
researchProduct

Strength Training: Single Versus Multiple Sets

1999

medicine.medical_specialtyEvidence-Based MedicineWeight LiftingSports medicinebusiness.industryStrength trainingMEDLINEReproducibility of ResultsData interpretationPhysical Therapy Sports Therapy and RehabilitationEvidence-based medicinecomputer.software_genreExercise TherapyText miningBiasResearch DesignData Interpretation StatisticalmedicineHumansOrthopedics and Sports MedicineArtificial intelligencebusinessPsychologycomputerNatural language processingSports Medicine
researchProduct

Randomised clinical trials: a source of ethical dilemmas

2001

Clinical trials give rise to ethical dilemmas, especially in the acutely ill, but we take issue with two points raised in a recent comment on a specific acute myocardial infarction (AMI) trial. The commentators judged that the trial most likely could, and therefore should, have been terminated much earlier. By analysing the problem statistically we arrive at results that go against their intuitive judgment—they also see it as mandatory to update the patient Information sheet as trial results accrue and trends begin to emerge. In our view, interpreting subtle trends and borderline p-values must rest with data monitoring boards, not patients. Moreover, patients with AMI or in other medical em…

medicine.medical_specialtyHealth (social science)medicine.medical_treatmentAt the Coalface: Medical Ethics in PracticeTreatment outcomeMyocardial InfarctionAlternative medicineHospital mortalityResearch EthicsArts and Humanities (miscellaneous)Informed consentAngioplastymedicineHumansEthics MedicalThrombolytic TherapyHospital MortalityMyocardial infarctionIntensive care medicineRandomized Controlled Trials as TopicInformed Consentbusiness.industryPatient SelectionHealth PolicyAngioplastyCoronary Care Unitsmedicine.diseasehumanitiesClinical trialIssues ethics and legal aspectsTreatment OutcomeClinical researchEthics ClinicalData Interpretation StatisticalMedical emergencybusinessJournal of Medical Ethics
researchProduct

Multimodality 3-dimensional volumetric ultrasound in obstetrics and gynecology with an emphasis in HDlive technique.

2013

HDlive (high-definition live or real-time US), a new ultrasound software, combines a movable virtual adjustable light source in a software that calculates the proportion of light reflecting through surface structures, depending on light direction. The light source can be manually positioned to illuminate the desired area of interest. The ultrasound technician can control light intensity to create shadows that enhance image quality. HDlive is an innovation that will render even more realistic images of fetal anatomy and of gynecologic lesions. The full potential of this new technology is yet to be determined and deserves scientific evaluation.

medicine.medical_specialtyImage qualityMultimodal ImagingMultimodalitySoftwareLight sourceObstetrics and gynaecologyComputer SystemsPregnancyImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingComputer visionDiagnostic Techniques Obstetrical and GynecologicalUltrasonographybusiness.industryEmphasis (telecommunications)UltrasoundImage EnhancementObstetric Labor ComplicationsLight intensityFemaleRadiologyArtificial intelligencebusinessGenital Diseases FemaleSoftwareUltrasound quarterly
researchProduct

Graph-matching based CTA.

2009

Separating bone, calcification, and vessels in computer tomography angiography (CTA) allows for a detailed diagnosis of vessel stenosis. This paper presents a new, graph-based technique that solves this difficult problem with high accuracy. The approach requires one native data set and one that is contrast enhanced. On each data set, an attributed level-graph is derived and both graphs are matched by dynamic programming to differentiate between bone, on one hand side, and vessel/calcification on the other hand side. Lumen and calcified regions are then separated by a profile technique. Evaluation is based on data from vessels of pelvis and lower extremities of elderly patients. Due to subst…

medicine.medical_specialtyMatching (graph theory)Computer scienceComputed tomographySensitivity and SpecificityPattern Recognition AutomatedArtificial IntelligencemedicineHumansSegmentationElectrical and Electronic EngineeringPelvisPeripheral Vascular DiseasesRadiological and Ultrasound Technologymedicine.diagnostic_testbusiness.industryAngiographyReproducibility of ResultsPattern recognitionNumerical Analysis Computer-AssistedImage segmentationmedicine.diseaseComputer Science ApplicationsRadiographic Image EnhancementStenosismedicine.anatomical_structureSubtraction TechniqueAngiographyRadiographic Image Interpretation Computer-AssistedRadiologyTomographyArtificial intelligencebusinessTomography X-Ray ComputedSoftwareAlgorithmsCalcificationIEEE transactions on medical imaging
researchProduct