Search results for " Image Interpretation"

showing 10 items of 50 documents

Reproducibility of CT Radiomic Features within the Same Patient: Influence of Radiation Dose and CT Reconstruction Settings.

2019

Background Results of recent phantom studies show that variation in CT acquisition parameters and reconstruction techniques may make radiomic features largely nonreproduceable and of limited use for prognostic clinical studies. Purpose To investigate the effect of CT radiation dose and reconstruction settings on the reproducibility of radiomic features, as well as to identify correction factors for mitigating these sources of variability. Materials and Methods This was a secondary analysis of a prospective study of metastatic liver lesions in patients who underwent staging with single-energy dual-source contrast material-enhanced staging CT between September 2011 and April 2012. Technique p…

MaleContrast MediaRadiation Dosage030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineMedicineHumansRadiology Nuclear Medicine and imagingProspective StudiesCluster analysisNeoplasm StagingReproducibilitybusiness.industryRadiation doseLiver NeoplasmsReproducibility of ResultsReconstruction algorithmMiddle AgedHierarchical clusteringFeature (computer vision)radiomics030220 oncology & carcinogenesisRadiographic Image Interpretation Computer-AssistedFemaleTomographybusinessNuclear medicineTomography X-Ray ComputedCt reconstructionAlgorithmsRadiology
researchProduct

Quantification of epicardial adipose tissue in coronary calcium score and CT coronary angiography image data sets: comparison of attenuation values, …

2016

The aim of the study was to compare epicardial adipose tissue (EAT) characteristics assessed with coronary calcium score (CS) and CT coronary angiography (CTCA) image data sets.In 76 patients (mean age 59 ± 13 years) who underwent CS and CTCA owing to suspected coronary artery disease (CAD), EAT was quantified in terms of density (Hounsfield units), thickness and volume. The EAT volume was extracted with a semi-automatic software.A moderate correlation was found between EAT density in CS and CTCA image data sets (-100 ± 19 HU vs -70 ± 24 HU; p  0.05, r = 0.55). The distribution of EAT was not symmetrical with a maximal thickness at the right atrioventricular groove (14.2 ± 5.3 mm in CS, 15.…

MaleCoronary angiographyComputed Tomography AngiographyAdipose tissueCoronary Artery Disease030204 cardiovascular system & hematologyCoronary AngiographySensitivity and Specificity030218 nuclear medicine & medical imagingCoronary artery disease03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineHounsfield scalemedicineHumansRadiology Nuclear Medicine and imagingVascular CalcificationAdiposityComputed tomography angiographyFull Papermedicine.diagnostic_testbusiness.industryReproducibility of ResultsMean ageGeneral MedicineMiddle Agedmedicine.diseaseCoronary Calcium ScoreAdipose Tissueepicardial adipose tissue CT coronary angiographyEpicardial adipose tissueRadiographic Image Interpretation Computer-AssistedFemaleSettore MED/36 - Diagnostica Per Immagini E RadioterapiabusinessNuclear medicinePericardiumAlgorithmsThe British Journal of Radiology
researchProduct

Distributed analysis of simultaneous EEG-fMRI time-series: modeling and interpretation issues

2009

Functional magnetic resonance imaging (fMRI) and electroencephalography (EEG) represent brain activity in terms of a reliable anatomical localization and a detailed temporal evolution of neural signals. Simultaneous EEG-fMRI recordings offer the possibility to greatly enrich the significance and the interpretation of the single modality results because the same neural processes are observed from the same brain at the same time. Nonetheless, the different physical nature of the measured signals by the two techniques renders the coupling not always straightforward, especially in cognitive experiments where spatially localized and distributed effects coexist and evolve temporally at different …

MaleDefault-modeBrain activity and meditationComputer scienceinstrumentation/methodsElectroencephalographycomputer.software_genreSynchronizationComputer-AssistedModelsEEGEvoked PotentialsDefault mode networkParametric statisticsVisual CortexBrain Mappingmedicine.diagnostic_testfMRISettore MED/37 - NeuroradiologiaElectroencephalographyMagnetic Resonance ImagingPattern Recognition VisualNeurologicalVisualAdultModels NeurologicalBiomedical EngineeringBiophysicsPattern RecognitionMachine learningEEG-fMRISensitivity and SpecificitymethodsImage Interpretation Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingComputer SimulationImage Interpretationbusiness.industryWorking memoryWorking memoryReproducibility of ResultsPattern recognitionAdult Brain Mapping; methods Computer Simulation Electroencephalography; methods Evoked Potentials; Visual; physiology Humans Image Interpretation; Computer-Assisted; methods Magnetic Resonance Imaging; instrumentation/methods Male Models; Neurological Pattern Recognition; physiology Reproducibility of Results Sensitivity and Specificity Visual Cortex; physiologyDistributed source modelingphysiologyEvoked Potentials VisualArtificial intelligencebusinessFunctional magnetic resonance imagingcomputer
researchProduct

Early evaluation using a radiomic signature of unresectable hepatic metastases to predict outcome in patients with colorectal cancer treated with FOL…

2020

PurposeThe objective of this study was to build and validate a radiomic signature to predict early a poor outcome using baseline and 2-month evaluation CT and to compare it to the RECIST1·1 and morphological criteria defined by changes in homogeneity and borders.MethodsThis study is an ancillary study from the PRODIGE-9 multicentre prospective study for which 491 patients with metastatic colorectal cancer (mCRC) treated by 5-fluorouracil, leucovorin and irinotecan (FOLFIRI) and bevacizumab had been analysed. In 230 patients, computed texture analysis was performed on the dominant liver lesion (DLL) at baseline and 2 months after chemotherapy. RECIST1·1 evaluation was performed at 6 months. …

MaleOncologyColorectal cancermedicine.medical_treatmentLeucovorinKaplan-Meier Estimate030218 nuclear medicine & medical imagingMESH: Camptothecin / administration & dosage; Camptothecin / analogs & derivatives; Colorectal Neoplasms / drug therapy; Colorectal Neoplasms / pathology; Computational Biology; Female0302 clinical medicineAntineoplastic Combined Chemotherapy ProtocolsProspective StudiesProspective cohort studyAged 80 and overLiver NeoplasmsGastroenterologyMESH: Radiographic Image Interpretation Computer-Assisted; Response Evaluation Criteria in Solid Tumors; Survival Rate;Tomography X-Ray ComputedMiddle AgedBevacizumabSurvival Rate030220 oncology & carcinogenesisCohortFOLFIRIRadiographic Image Interpretation Computer-AssistedFemaleFluorouracilColorectal NeoplasmsClinical decision makingmedicine.drugAdultmedicine.medical_specialtyBevacizumab[SDV.CAN]Life Sciences [q-bio]/CancerMESH: Fluorouracil / administration & dosage; Humans; Kaplan-Meier Estimate; Leucovorin / administration & dosage; Liver Neoplasms / diagnostic imagingComputerised image analysis03 medical and health sciencesColorectal metastasesMESH: Adult; Aged 80 and over; Antineoplastic Combined Chemotherapy Protocols / administration & dosage; Bevacizumab / administration & dosage; Camptothecin / administration & dosagePredictive Value of TestsInternal medicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingmedicineHumansChemotherapyResponse Evaluation Criteria in Solid TumorsMESH: Liver Neoplasms / secondary; Male; Middle Aged; Predictive Value of Tests; Prospective StudiesAgedChemotherapybusiness.industryComputational Biology[SDV.MHEP.HEG]Life Sciences [q-bio]/Human health and pathology/Hépatology and Gastroenterologymedicine.diseaseColorectal cancerLog-rank testIrinotecanCamptothecinTomography X-Ray ComputedbusinessGut
researchProduct

ECG-GATED MULTIDETECTOR COMPUTED TOMOGRAPHY FOR THE ASSESSMENT OF THE POSTOPERATIVE ASCENDING AORTA

2009

This study was undertaken to define the role of electrocardiographically (ECG)-gated multidetector computed tomography (MDCT) in the assessment of the postoperative ascending aorta. From November 2006 to June 2007, 21 patients, [11 men, ten women; age +/- standard deviation (SD): 62.7 +/- 10.8 years] with a history of ascending aorta replacement underwent ECG-gated MDCT and were prospectively included in our study. Ascending aorta replacement had been performed with different surgical techniques: Bentall-De Bono (four patients, 19%), Tirone-David (five patients, 23%), and modified Tirone-David with creation of aortic neosinuses (12 patients, 57%). Two patients were excluded from MDCT evalua…

Malemedicine.medical_specialtyAortic DiseasesContrast MediaAorta ThoracicBlood Vessel Prosthesis ImplantationElectrocardiographyPostoperative ComplicationsAortic valve replacementECG gatingmedicine.arteryAscending aortaMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingAortic valve prosthesicardiovascular diseasesAortaNeuroradiologyAortamedicine.diagnostic_testbusiness.industryMultidetector CTUltrasoundInterventional radiologySettore MED/23 - Chirurgia CardiacaGeneral MedicineMiddle Agedmedicine.diseaseIopamidolAortic valve replacementTreatment OutcomeEchocardiographyEcg gatingcardiovascular systemRadiographic Image Interpretation Computer-AssistedFemaleRadiologybusinessTomography X-Ray ComputedSettore MED/36 - Diagnostica Per Immagini E Radioterapia
researchProduct

Diagnostic performance of whole brain volume perfusion CT in intra-axial brain tumors: preoperative classification accuracy and histopathologic corre…

2012

Abstract Background To evaluate the preoperative diagnostic power and classification accuracy of perfusion parameters derived from whole brain volume perfusion CT (VPCT) in patients with cerebral tumors. Methods Sixty-three patients (31 male, 32 female; mean age 55.6 ± 13.9 years), with MRI findings suspected of cerebral lesions, underwent VPCT. Two readers independently evaluated VPCT data. Volumes of interest (VOIs) were marked circumscript around the tumor according to maximum intensity projection volumes, and then mapped automatically onto the cerebral blood volume (CBV), flow (CBF) and permeability Ktrans perfusion datasets. A second VOI was placed in the contra lateral cortex, as cont…

Malemedicine.medical_specialtyPerfusion ImagingHemodynamicsSensitivity and Specificity030218 nuclear medicine & medical imagingCorrelation03 medical and health sciences0302 clinical medicineImaging Three-DimensionalCortex (anatomy)Preoperative CaremedicineHumansRadiology Nuclear Medicine and imagingNeovascularization Pathologicbusiness.industryBrain NeoplasmsReproducibility of ResultsGeneral MedicineMiddle AgedPrognosisTumor BurdenCerebral blood volumemedicine.anatomical_structureMaximum intensity projectionBrain sizeCerebral hemisphereRadiographic Image Interpretation Computer-AssistedFemaleRadiologyNuclear medicinebusinessTomography X-Ray ComputedPerfusion030217 neurology & neurosurgeryAlgorithmsEuropean journal of radiology
researchProduct

Three-Dimensional Analysis of Component Stability of the Nellix Endovascular Aneurysm Sealing System After Treatment of Infrarenal Abdominal Aortic A…

2016

Purpose: To assess short-term stability and conformational changes of the Nellix EndoVascular Aneurysm Sealing (EVAS) System using 3-dimensional (3D) analysis. Methods: Postoperative computed tomography (CT) scans obtained at 0, 3, and 12 months in 24 patients (mean age 75±7 years; 22 men) who underwent EVAS between December 2013 and December 2014 for intact abdominal aortic aneurysm (within the instructions for use) were evaluated for stent-graft deviation in multiple planes using dedicated 3D analysis software. In addition, 2D analysis using an anatomically fixed reference landmark was performed to assess craniocaudal migration. Clinical and follow-up data of the patients were recorded a…

Malemedicine.medical_specialtyThree dimensional analysisTime FactorsEndoleak3d analysisComputed tomography030204 cardiovascular system & hematologyProsthesis DesignAortography030218 nuclear medicine & medical imagingBlood Vessel Prosthesis Implantation03 medical and health sciencesImaging Three-Dimensional0302 clinical medicineAneurysmForeign-Body MigrationPredictive Value of TestsHumansMedicineRadiology Nuclear Medicine and imagingAgedRetrospective StudiesComputed tomography angiographyAged 80 and overmedicine.diagnostic_testbusiness.industryEndovascular ProceduresMean ageMiddle Agedmedicine.diseaseAbdominal aortic aneurysmBlood Vessel ProsthesisTreatment OutcomeRadiographic Image Interpretation Computer-AssistedFemaleStentsSurgeryRadiologyCardiology and Cardiovascular MedicinebusinessAfter treatmentAortic Aneurysm AbdominalJournal of Endovascular Therapy
researchProduct

MDCT and virtual angioscopy in spontaneous aortocaval fistula

2007

Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…

Malemedicine.medical_specialtymedicine.medical_treatmentFistulaAngioscopyVena Cava InferiorInferior vena cavaAortographyAortic aneurysmUser-Computer InterfaceAneurysmFatal OutcomeImaging Three-DimensionalcavaLaparotomymedicineHumansfistulaRadiology Nuclear Medicine and imagingcardiovascular diseasesAgedMDCT angioscopymedicine.diagnostic_testbusiness.industryvirtual angioscopyPhlebographymedicine.diseaseAngioscopyAbdominal aortic aneurysmaortamultidetector row ctmedicine.veinArteriovenous Fistulacardiovascular systemRadiographic Image Interpretation Computer-AssistedRadiologyRenal veinCardiology and Cardiovascular MedicinebusinessTomography X-Ray ComputedVascular Surgical Proceduresaorta; cava; fistula; multidetector row ct; virtual angioscopyAortic Aneurysm Abdominal
researchProduct

Tako-tsubo cardiomyopathy and microcirculation.

2010

Takotsubo cardiomyopathy was described for the first time in Japan in the 1990s. It is very similar to the ischemic cardiopathy both for clinical and instrumental characteristics. His peculiarity is an alteration of the ventricular contraction mechanism with hypo-akinesis of the apex and lateral segments of the left ventricle, associated with hyper-kinesis of the heart base which is responsible for the typical echocardiographic aspect of a cruet during the systole. However, the etiology of this cardiomyopathy is still unknown despite the fact that numerous hypothesis have been made. A single study of 16 patients proved multivasal damage by a BLASH SCORE analysis of the coronary radiography.…

Malemedicine.medical_specialtytako-tsubo cardiomyopathyCardiomyopathycoronary microcirculation; takotsubo; timi frame countHemodynamicsHealth InformaticsAnterior Descending Coronary ArteryCritical Care and Intensive Care MedicineCoronary AngiographyMicrocirculationTakotsubo CardiomyopathyInternal medicinemedicine.arteryCoronary CirculationMedicineHumansAgedbusiness.industryMicrocirculationmedicine.diseaseStenosisAnesthesiology and Pain Medicinemedicine.anatomical_structureRight coronary arteryCardiologyRadiographic Image Interpretation Computer-AssistedFemalebusinessTIMIBlood Flow VelocityArteryJournal of clinical monitoring and computing
researchProduct

Influence of pixel size on quantification of airway wall thickness in computed tomography.

2009

Objectives: The purpose of this study was to determine the point where a further decrease in voxel size does not result in better automatic quantification of the bronchial wall thickness by using 2 different assessment techniques. Materials and Methods: The results from the commonly used full-width-at-half-maximum (FWHM) principle and a new technique (integral-based method [IBM]) were compared for thin-section multidetector computed tomography (MDCT) data sets from an airway phantom containing 10 different tubular airway phantoms and in a human subsegmental bronchus in vivo. Correlation with the actual wall thickness and comparison of the wall thicknesses assessed for different voxel sizes …

Pixelmedicine.diagnostic_testbusiness.industryPhantoms ImagingComputed tomographyField of viewBronchiBronchographycomputer.software_genreImaging phantomRadiographic Image EnhancementFull width at half maximumVoxelApproximation errorComputer GraphicsMedicineHumansRadiographic Image Interpretation Computer-AssistedRadiology Nuclear Medicine and imagingbusinessNuclear medicineTomography X-Ray ComputedImage resolutioncomputerSoftwareJournal of computer assisted tomography
researchProduct