Search results for " Impedance"
showing 10 items of 380 documents
Evaluation of an Optical Energy Harvester for SHM Application
2019
Abstract In this paper a preliminary study on an array configuration of rectified optical nanoantennas for energy harvesting application is proposed. Currently, the major impediments for the use of the rectified optical nanoantenna known as rectenna are the relatively low conversion efficiency and low power transfer to the load, both of them caused mainly by the mismatch between the impedance of the rectifier (several kilo ohms) and that of the antenna (hundreds of ohm). For this reason, the design of the array represents a crucial point to obtain the maximum energy transfer from the rectenna to the load, represented as a typical DC/DC boost power converter, and modeled by an equivalent inp…
Investigation of lattice dynamical and dielectric properties of MgO under high pressure by means of mid- and far-infrared spectroscopy.
2013
We investigate the lattice dynamical and dielectric properties of MgO single crystals and powders by measurements in the mid- and far-infrared frequency region under high pressures, ranging up to 21.7 GPa. The shift of the restrahlen region is used to determine the pressure dependence of the transverse and longitudinal optical modes. The analysis of the refractive index in the mid- and far-infrared region allowed us to obtain the pressure behavior of the static and electronic dielectric constants. The transverse effective charge slowly decreases under high pressure, reflecting the stability of MgO. As a consequence, the pressure dependence of the static and electronic dielectric constants i…
EQCM and Quartz Crystal Impedance Measurements for the Characterization of Thiophene-Based Conducting Polymers
1999
AbstractEQCM was extensively used to investigate ion-transport phenomena during dopingundoping processes of electronically conducting polymers. Several early studies assumed that the polymer films were rigidly coupled to the quartz crystal so as to relate the mass change to the quartz crystal resonant frequency change via the Sauerbrey equation. However, the rigidity of electronically conducting polymer films is doubtful and it has to be demonstrated. Quartz crystal impedance analysis near the resonance is of paramount importance to get insight into the viscoelastic properties of the film [1] and to avoid misleading in the interpretation of EQCM data.This contribution presents and discusses…
Protonic ceramic fuel cell : elaboration and characterization. Investigation of the BaZr0.8Y0.2O3-d electrolyte by electrochemical impedance spectros…
2021
One of the current global challenges is to find novel, clean and efficient techniques for the energy production. The use of electrochemical cells and hydrogen is one of the solutions. These cells convert the excess energy produced by conventional systems into hydrogen by steam electrolysis. The hydrogen can be stored and transformed into electricity when needed in the fuel cell mode. Among the different electrochemical cells, protonic ceramic electrochemical cells have attracted much attention due to their high efficiency at intermediate temperature (400 – 600 °C). In addition, these systems offer the advantage of not diluting the fuel in electrolysis mode. This thesis work focuses on the e…
Short-term walking physical training and changes in body hydration status, B-type natriuretic peptide and C-reactive protein levels in compensated co…
2008
BACKGROUND: Congestive heart failure (CHF) is associated with decreased exercise tolerance, alterations in body fluid balance and activation of neurohumoral and inflammatory pathways. Physical training, despite the contraindications of the past, is recommended for its beneficial effects on exercise capacity and quality of life. We investigate the effects of a short-term (ten weeks) walking physical training program (PT) on body hydration state (HS), B-type natriuretic peptide (BNP) and C-reactive protein (CRP) levels. METHODS AND RESULTS: 22 patients with CHF (mean age 62.7+/-4.8 years, 15 men, mean ejection fraction 38.9+/-3.6%, NYHA class II-III), were enrolled. Eleven patients were rando…
Archaeometric analysis of Roman bronze coins from the Magna Mater temple using solid-state voltammetry and electrochemical impedance spectroscopy
2017
Voltammetry of microparticles (VMP) and electrochemical impedance spectroscopy (EIS) techniques, complemented by SEM-EDX and Raman spectroscopy, were applied to a set of 15 Roman bronze coins and one Tessera from the temple of Magna Mater (Rome, Italy). The archaeological site, dated back between the second half and the end of the 4th century A.D., presented a complicated stratigraphic context. Characteristic voltammetric patterns for cuprite and tenorite for sub-microsamples of the corrosion layers of the coins deposited onto graphite electrodes in contact with 0.10 M HClO4 aqueous solution yielded a grouping of the coins into three main groups. This grouping was confirmed and refined usin…
Electrochemical discrimination of mints: The last Chinese emperors Kuang Hsü and Hsüan T'ung monetary unification.
2017
[EN] An electrochemical methodology for discriminating monetary emissions, a recurrent problem in much archaeological studies, is introduced. The method is based on the record of voltammetric signatures of cuprite and tenorite corrosion products in the patina using a minimally invasive nanosampling following the voltammetry of immobilized particles methodology. A model for the depth variation of voltammetric electrochemical parameters characterizing the composition of the corrosion patinas is presented. This model permits to rationalize electrochemical data and discriminate different monetary emissions. The application of this technique, corroborated by electrochemical impedance spectroscop…
A DC and small signal AC model for organic thin film transistors including contact effects and non quasi static regime
2017
Abstract We present a compact model for the DC and small signal AC analysis of Organic Thin Film Transistors (OTFTs). The DC part of the model assumes that the electrical current injected in the OTFT is limited by the presence of a metal/organic semiconductor junction that, at source, acts as a reverse biased Schottky junction. By including this junction, modeled as a reverse biased gated diode at source, the DC model is able to reproduce the scaling of the electrical characteristics even for short channel devices. The small signal AC part of the model uses a transmission line approach in order to compute the impedances of the channel and parasitic regions of the device. The overlap capacit…
Body composition in 18 to 88-year-old adults - comparison of multifrequency bioimpedance and dual-energy X-ray absorptiometry
2014
Objective -- This study compared bioimpedance analysis (BIA) in the assessment of body composition with dual-energy X-ray absorptiometry (DXA) in 18- to 88-year-old adults. Design and Methods -- Body composition of 882 adults was estimated by eight-polar BIA and DXA. In addition, estimates of lean mass, fat mass, and percentage of fat were investigated across a range of age and leisure time physical activity (LTPA) groups. Results -- Compared to DXA, larger lean masses (mean difference 2.9 and 1.6 kg) and smaller fat masses (3.1 and 2.6 kg) were estimated by BIA in both women and men, respectively. Differences between the methods' mean values were evident in all age and LTPA groups, except …
Transthoracic electrical impedance during extracorporeal hemodialysis in acute respiratory failure ("Shocked Lung syndrome").
1980
The alteration (delta Z0) of transthoracic electrical impedance (TEI) during extracorporeal hemodialysis (EHD) was investigated in two Groups of patients with acute renal and acute respiratory failure, that differed with respect to the severity of respiratory insufficiency. Group I had moderate respiratory failure (FiO2 0.31 +/- 0.10, PaO2 84 +/- 14 mmHg), and Group II had severe respiratory failure (FiO2 0.75 +/- 0.17, PaO2 77 +/- 14 mmHg). There was a significant correlation between increase in TEI (delta Z0) and decrease in body weight (delta BW) in each individual patient, but the slope of regression lines was remarkably flattened in Group II. In Group I, delta TEI was 1.9 +/- 0.9 omega…