Search results for " Infrared Spectroscopy"
showing 10 items of 438 documents
Application of point-to-point matching algorithms for background correction in on-line liquid chromatography–Fourier transform infrared spectrometry …
2009
A new background correction method for the on-line coupling of gradient liquid chromatography and Fourier transform infrared spectrometry has been developed. It is based on the use of a point-to-point matching algorithm that compares the absorption spectra of the sample data set with those of a previously recorded reference data set in order to select an appropriate reference spectrum. The spectral range used for the point-to-point comparison is selected with minimal user-interaction, thus facilitating considerably the application of the whole method. The background correction method has been successfully tested on a chromatographic separation of four nitrophenols running acetonitrile (0.08…
Determination of critical eluent composition for polyethylenglycols using on-line liquid chromatography-Fourier transform infrared spectrometry.
2008
In this work, it has been extended to methanol:water mobile phases, the use of a background correction method for on-line LC-FTIR measurements named Univariate background correction based on the use of a reference spectra matrix (UBC-RSM) and absorbance ratios. It permits to overcome the problem related to spectral changes occurring during the gradient elution, which in the past limited the on-line coupling of LC and FTIR to isocratic elutions. The combined use of the aforementioned background correction technique in on-line isocratic and gradient LC-FTIR, and partial least squares (PLS) has been applied for the search of the critical conditions for polymers. Polyethylenglycol (PEG) has bee…
Univariate method for background correction in liquid chromatography–Fourier transform infrared spectrometry
2007
An univariate method is proposed for background correction in on-line gradient liquid chromatography-Fourier transform infrared (LC-FTIR) spectrometry using acetonitrile:water as mobile phase components. The method is based on the calculation of the ratio of absorbances (AR) at two characteristic wavenumbers for each spectrum. This parameter is subsequently used to locate the most appropriated eluent spectrum within a reference spectra matrix (RSM) to be subtracted from each spectrum included in the sample chromatogram. To correct minor changes in eluent spectra intensity during the elution of analytes, a correction factor (Kf), defined as the ratio of the absorbance of the sample and the s…
Seafood freshness determination through vapour phase Fourier transform infrared spectroscopy.
2006
Abstract A new vapour-phase manifold has been developed to determine trimethylamine (TMA) in fish and cephalopod samples by Fourier transform infrared (FT-IR) spectroscopy. Samples were treated off-line for 1 h with trichloroacetic acid (TCA), filtered and washed. The obtained extracts were aspirated and alkalinized with NaOH 2.0 M, in an on-line system. TMA was separated from the solution in a gas phase separator and then transported by means of a nitrogen carrier into a home made 10 cm pathlength IR gas cell, where the corresponding FT-IR spectra were acquired by accumulating 30 scans per spectrum with 2 cm−1 nominal resolution. The method was applied to the determination of TMA in natura…
Evaluation of extraction alternatives for Fourier transform infrared spectrometric determination of oil and greases in water
1997
Abstract Liquid-liquid extraction (LLE), solid phase extraction (SPE) and microwave-assisted extraction are evaluated for Fourier transform infrared (FTIR) spectrometric determination of oil and grease in polluted waters. A fast microwave-assisted quantitative procedure is proposed for the total extraction of oil and grease into CCl 4 from water samples, with an irradiation time of 1 min at an exit power of 520 W using closed PTFE vessels. The FTIR quantification of oil and grease is carried out by the measurement of the area under the absorbance spectra in the range between 3058 and 2780 cm −1 , with a baseline established between 3200 and 2700 cm −1 . The analytical features of the propos…
Thermally Induced Isomerisation Kinetics of the 9c11t and 10t12c Conjugated Linoleic Acids in Triacylglycerols as Studied by FT-IR Spectrometry Aided…
2014
Published version of an article from the journal:The Open Spectroscopy Journa. Also available from the publisher:http://dx.doi.org/10.2174/1874383801004010041. Open Access Isomerisation kinetics of the 9c11t and 10t12c Conjugated Linoleic Acids (CLA) in triaclglycerols at isothermal conditions (250, 280 and 325oC) has been studied by infrared spectroscopy. Fifteen micro liter portions of the glycerides were placed in micro glass ampoules and sealed under nitrogen. Several glass tubes containing the same triacylglycerols were then subjected to thermal treatment. The glass tubes were removed at regular time intervals, cut open, and a part of the contents in each glass tube analysed by infrare…
Liquid chromatography-Fourier transform infrared spectrometric determination of cholesterol in animal greases
1997
Abstract Stearic acid, cholesterol and cholesteryl palmitate have been separated in less than 14 min by liquid chromatography on a column (3.9 mm i.d.×150 mm) of Nova-Pack C 18 (5 μm) using chloroform–acetonitrile (45 : 55) as mobile phase pumped at 0.5 ml min −1 ; Fourier transform infrared (FTIR) spectrometry was employed for both, general detection at 2868 or 2855 cm −1 and selective detection at 3285 cm −1 for stearic acid and 3526 cm −1 for cholesterol. In all cases a baseline established at 3900 cm −1 , 9-point smoothing and chromatographic peak height measurements were used. The method has been validated by application to the determination of cholesterol in animal greases and fish oi…
Comparison of two vibrational procedures for the direct determination of mancozeb in agrochemicals.
2007
The direct determination of mancozeb in agrochemicals has been made by diamond attenuated total reflectance (ATR) Fourier transform infrared spectroscopy in the middle range (DATR-MIR) and diffuse reflectance infrared Fourier transform spectroscopy in the near range (DR-NIR) methods using in both cases a previous identification of the samples using a dendrographic classification and an appropriate partial least squares (PLS) calibration established from a set of nine external standards and optimized for each type of sample. It was analyzed a heterogeneous population of 11 samples obtained from the Spanish market, containing different co-formulated products, such as fosetyl-Al, copper oxychl…
Miniature diamond-anvil cells for FTIR-microspectroscopy of small quantities of biosamples.
2018
Fourier transform infrared (FTIR) spectroscopy techniques and data analyses have become widely available, are easy to use, and are convenient for studies of various biosamples, especially in biomedical science. Yet, cultivation of cells and purification of cell components are costly, often methodically challenging, and time and labor consuming. Therefore, reduction of the sample amount is of high value. Here we propose a novel method for the analysis of small quantities of biosamples by FTIR-microscopy of dry films using a diamond-anvil cell (DAC). This approach allows us to decrease the sample volume at least a hundred times compared to that for a high-throughput screening device (HTS-XT, …
Essential oil counterfeit identification through middle infrared spectroscopy
2018
Abstract Infrared spectroscopy (FTIR) has been employed for a fast quality control of commercial essential oils from different plant species. 47 samples were obtained from Algerian and Spanish market and directly measured, without any previous treatment, by attenuated total reflectance Fourier transform Infrared spectroscopy (ATR-FTIR), in the wavenumber region between 4000 and 550 cm−1. Pure essential oils were obtained by hydro- and steam-distillation extraction methods and their ATR spectra obtained. Results found evidenced the presence of solvents in some commercial formulations and permitted a rapid authentication of pure essential oils correctly extracted from those diluted. The propo…