Search results for " Instrumentation."
showing 10 items of 712 documents
Deep learning for multimessenger core-collapse supernova detection
2020
The detection of gravitational waves from core-collapse supernova (CCSN) explosions is a challenging task, yet to be achieved, in which it is key the connection between multiple messengers, including neutrinos and electromagnetic signals. In this work, we present a method for detecting these kind of signals based on machine learning techniques. We tested its robustness by injecting signals in the real noise data taken by the Advanced LIGO-Virgo network during the second observation run, O2. We trained a newly developed Mini-Inception Resnet neural network using time-frequency images corresponding to injections of simulated phenomenological signals, which mimic the waveforms obtained in 3D n…
Relativistic Positioning Systems: current status
2009
A {\em relativistic positioning system} consists in a set of four clocks broadcasting their respective proper time by means of light signals. Among them, the more important ones are the {\em auto-located positioning systems,} in which every clock broadcasts not only its proper time but also the proper times that it receives from the other three. At this level, no reference to any exterior system (the Earth surface, for example) and no synchronization are needed. The current status of the theory of relativistic positioning systems is sketched.
Non-linear cosmological collapse of quintessence
2015
We present a study of the fully relativistic spherical collapse in presence of quintessence using on Numerical Relativity, following the method proposed by the authors in a previous article [arXiv:1409.3476]. We ascertain the validity of the method by studying the evolution of a spherically symmetric quintessence inhomogeneity on a de Sitter background and we find that it has an impact on the local expansion around the centre of coordinates. We then proceed to compare the results of our method to those of the more largely adopted top-hat model. We find that quintessence inhomogeneities do build up under the effect that matter inhomogeneities have on the local space-time yet remain very smal…
Denoising of gravitational-wave signal GW150914 via total-variation methods
2016
We apply a regularized Rudin-Osher-Fatemi total variation (TV) method to denoise the transient gravitational wave signal GW150914. We have previously applied TV techniques to denoise numerically generated grav- itational waves embedded in additive Gaussian noise, obtaining satisfactory results irrespective of the signal morphology or astrophysical origin. We find that the non-Gaussian, non-stationary noise from the gravitational wave event GW150914 can also be successfully removed with TV-denoising methods. The quality of the de- noised waveform is comparable to that obtained with the Bayesian approach used in the discovery paper [1]. TV-denoising techniques may thus offer an additional via…
The thermal neutron capture cross section of the radioactive isotope $^{60}$Fe
2015
50% of the heavy element abundances are produced via slow neutron capture reactions in different stellar scenarios. The underlying nucleosynthesis models need the input of neutron capture cross sections. One of the fundamental signatures for active nucleosynthesis in our galaxy is the observation of long-lived radioactive isotopes, such as $^{60}$Fe with a half-life of $2.60\times10^6$ yr. To reproduce this $\gamma$-activity in the universe, the nucleosynthesis of $^{60}$Fe has to be understood reliably. A $^{60}$Fe sample produced at the Paul-Scherrer-Institut was activated with thermal and epithermal neutrons at the research reactor at the Johannes Gutenberg-Universit\"at Mainz. The therm…
Future use of silicon photomultipliers for Kaos at MAMI and P¯ANDA at FAIR
2009
A characterisation of scintillating fibres with silicon photomultiplier read-out was performed in view of their possible application in fibre tracking detector systems. Such a concept is being considered for the Kaos spectrometer at the Mainz Microtron MAMI and as a time-of-flight start detector for the hypernuclear physics programme at the PANDA experiment of the FAIR project. Results on particle detection effciency and time resolution are discussed. In summary, the silicon devices are very suitable for the detection of the low light yield from scintillating fibres insofar a trigger scheme is found to cope with the noise rate characteristics.
Testing the X-IFU calibration requirements: an example for quantum efficiency and energy resolution
2018
With its array of 3840 Transition Edge Sensors (TESs) operated at 90 mK, the X-Ray Integral Field Unit (X-IFU) on board the ESA L2 mission Athena will provide spatially resolved high-resolution spectroscopy (2.5 eV FWHM up to 7 keV) over the 0.2 to 12 keV bandpass. The in-flight performance of the X-IFU will be strongly affected by the calibration of the instrument. Uncertainties in the knowledge of the overall system, from the filter transmission to the energy scale, may introduce systematic errors in the data, which could potentially compromise science objectives - notably those involving line characterisation e.g. turbulence velocity measurements - if not properly accounted for. Defining…
Design of a virtual instrument for water quality monitoring across the Internet
2001
Abstract This article presents the design of a new distributed and multi-platform system for water quality monitoring, enhanced with powerful Internet capabilities. The measured variables are temperature, turbidity, pH, dissolved oxygen, and electrical conductivity. The signal-conditioning block has been simplified through the use of software routines for thermal compensation, hence, reducing the cost and dimensions. The system offers a wide variety of Internet capabilities, like e-mail alarm notifications, automatic storage of measured data in a remote machine via the FTP protocol, dynamic generation of HTML reports, real time graphs, and indicators visible from a remote web browser, etc. …
Autonomous on-board data processing and instrument calibration software for the SO/PHI
2018
The extension of on-board data processing capabilities is an attractive option to reduce telemetry for scientific instruments on deep space missions. The challenges that this presents, however, require a comprehensive software system, which operates on the limited resources a data processing unit in space allows. We implemented such a system for the Polarimetric and Helioseismic Imager (PHI) on-board the Solar Orbiter (SO) spacecraft. It ensures autonomous operation to handle long command-response times, easy changing of the processes after new lessons have been learned and meticulous book-keeping of all operations to ensure scientific accuracy. This contribution presents the requirements a…
Improved resolution power of electrophoretic fractionation of DNA using a voltage gradient up and down application
2004
The improved resolution power of electrophoretic fractionation of DNA in a wide range of molecular masses is demonstrated using an "up and down" application of voltage gradient gel electrophoresis (VGGE). This application also allows separation of different DNA fragments which are poorly fractionated in conventional electrophoresis.